Images are representations only.

Model 2400XFS Low Pressure M/P Converter

Brand: Fairchild Industrial Products
Explosion-proof DC Pulse Input (XS): The Rotork Fairchild Model 2400 M/P Converter is isolated from an explosive environment by enclosing in an Explosion-proof housing.

The Stepper Motor configuration is equipped with a clock generator positioned horizontally, which plugs into a vertically mounted translator board. The configuration includes limit switches.

The Stepper Motor is mounted on the bottom of the motor assembly in the base of the Explosion-proof housing.

Wiring to the unit is made to a terminal board through a 1/2" - 14 NPT conduit fitting in the base of the housing. The unit includes two single pole, double throw, double break limit switches.

Switches on the clock generator board allow selection of: a) Internally or Externally Powered Controls Loops b) Half-step or Full Step Mode c) High-Speed or Low-Speed Operation
Explosion-proof DC Pulse Input (XS): The Rotork Fairchild Model 2400 M/P Converter is isolated from an explosive environment by enclosing in an Explosion-proof housing.

The Stepper Motor configuration is equipped with a clock generator positioned horizontally, which plugs into a vertically mounted translator board. The configuration includes limit switches.

The Stepper Motor is mounted on the bottom of the motor assembly in the base of the Explosion-proof housing.

Wiring to the unit is made to a terminal board through a 1/2" - 14 NPT conduit fitting in the base of the housing. The unit includes two single pole, double throw, double break limit switches.

Switches on the clock generator board allow selection of: a) Internally or Externally Powered Controls Loops b) Half-step or Full Step Mode c) High-Speed or Low-Speed Operation

Specifications

Approvals & Certifications

  • FM Explosion-proof for Class I, Div. 1, Groups B, C, D & Class II, Div. 1, Groups E, F, G,

Electrical Contacts

  • Normally Closed
  • Normally Open

Enclosure, Body Material

  • Aluminum

Environmental Protection

  • Explosion-proof
  • NEMA 4X

Input

  • 24 Vdc

Power Options

  • DC Motor / Pulse

Power Requirement

  • 12-24 Vdc

Pressure Range

  • bar: 0 to 0.048
  • Inches WC: 0 to 200
  • kPa: 0 to 4.8
  • psig: 0 to 0.7

Supply Pressure - Maximum

  • bar: 1.4 to 10
  • kPa: 138 to 1,000
  • psi: 20 to 150

Trim Material

  • Stainless Steel