2710 Tension & Compression Load Cell

Brand: Sensy - Sensors & Synergy S.A.
Universal load cell combining accuracy, sturdiness and easiness to install.
Features
  • Stainless steel
  • Protection IP 67
  • Compact design
  • Available options (non exhaustive list):
    • ATEX intrinsic safety Ex II 1GD Ex ia IIC T6 or T4 Ga Ex ia IIIC T80° C Da
    • Cable output by connector
    • High service temperature (180° C)
show more
Universal load cell combining accuracy, sturdiness and easiness to install.
Features
  • Stainless steel
  • Protection IP 67
  • Compact design
  • Available options (non exhaustive list):
    • ATEX intrinsic safety Ex II 1GD Ex ia IIC T6 or T4 Ga Ex ia IIIC T80° C Da
    • Cable output by connector
    • High service temperature (180° C)

Specifications

Accuracy

  • 0.03 % of Full Scale
  • 0.1 % of Full Scale

Applications

  • Conveyors
  • Hoppers
  • Long Period Force Measurements
  • Reactors
  • Weighing

Approvals & Certifications

  • ATEX Intrinsic Safety Ex II 1 GD Ex ia IIC T6 or T4 Ga Ex ia IIIC T80° C Da
  • CE

Cable Length

  • 10 feet (3 metres)

Capacity

  • 500 to 5,000 kg

Electrical Connectors

  • Male DIN 45322

Enclosure, Body Material

  • Stainless Steel

Environmental Protection

  • IP67

Excitation Voltage

  • 10 Vdc
  • 3-12 Vdc - Nominal Range

Insulation Resistance

  • > 5,000 megaohms

Linearity

  • Linearity Error: < ± 0.025 % (Class 0.03) to < ± 0.1 % (Class 0.1) of Full Scale

Load Limit

  • 120 % of Full Scale

Operating Temperature

  • 180° C (356° F)

Repeatability

  • Error: < ± 0.015 % (Class 0.03) to < ± 0.03 % (Class 0.1) of Full Scale

Resistance

  • Input/Output: 352 ± 2 ohms

Sensitivity

  • Nominal: 2 mV/V
  • Tolerance: < ± 0.2 % (Class 0.03) to < ± 0.3 % (Class 0.1)

Service Temperature

  • -30° to 70° C (-22° to 158° F)

Static Lateral Force

  • Limit: 50 % of Full Scale

Temperature Coefficient

  • < ± 0.015 % of Full Scale/10° C (18° F)
  • < ± 0.023 % of Full Scale/10° C (18° F)
  • < ± 0.035 % of Full Scale/10° C (18° F)
  • < ± 0.05 % of Full Scale/10° C (18° F)

Zero Balance