Description
For the Highest Demands
The Intrinsically-Safe model IL-10 submersible pressure transmitter has been designed for the highest requirements of level measurement. Owing to its high accuracy, reliability and its excellent media resistance, it is the ideal solution for almost all level measurements in hazardous areas.
Especially noteworthy are the outstanding approval-related characteristics (IECEx and ATEX). In addition, the IL-10 has the North-American approvals FM (USA) and CSA (Canada).
Design
A hermetically sealed and robust stainless steel case with ingress protection IP68 enables immersion depths of up to 300 m.
The submersible pressure transmitter is supplied with a power supply of DC 10-30 V via a suitable isolated barrier and provides an output signal of 4-20 mA, 2-wire.
Features- Suitable for all level measurements in hazardous areas
- Explosion protection in accordance with IECEx, ATEX, FM and CSA
- Shipbuilding approval in accordance with GL
- Ingress protection IP68 up to 300 m immersion depth
Configure
Specifications
Specifications
Accuracy
- ≤ ± 0.25 % of Span - Including Non-Linearity, Hysteresis, Zero Offset & End Value Deviation (Corresponds to Measured Error Per IEC 61298-2)
- ≤ ± 0.5 % of Span
Ambient Temperature Range
- -30° to 105° C (-22° to 221° F)
Applications
- Brackish Water & Fuel Tanks in Shipbuilding
- Mining & Gas Extraction
- Oil & Fuel Storage Tanks
- Wastewater Treatment & Biogas Production
Approvals & Certifications
- ATEX - Ex I, Zone 1 Gas, [II 2 G Ex ia IIC T4/T5/T6 Gb]
- ATEX - Mining, [I M1 Ex ia I Ma]
- ATEX - Zone 0 Gas, [II 1 G Ex ia IIA T4/T5/T6 Ga]
- ATEX - Zone 1 Mounting to Zone 0 Gas, [II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb]
- ATEX - Zone 20 Dust, [II 1D Ex ia IIIC T120° C Da]
- BelCT
- CE
- CRN - Safety (e.g. Electr. Safety, Overpressure, to), Canada
- CSA - Canadian Zone Designation: Class I, Zone 0, Ex ia, IIC, IP65, DIP A20
- CSA - Hazardous Areas, Class I, Div. 1, Groups A, B, C, D. Class II, Groups E, F, G, Class III.
- CSA - Safety (e.g. Electr. Safety, Overpressure, to)
- CSA - US Zone Designation: Class I, Zone 0, AEx ia, IIC, IP65
- EAC - Hazardous Areas, Ex I, Zone 1 Gas, [1ExiaIICT4/T5/T6 X]
- EAC - Mining, [POExiaI X]
- EAC - Zone 0 Gas, [0ExiaIIAT4/T5/T6 X]
- EAC - Zone 1 Mounting to Zone 0 Gas, [1ExiaIICT4/T5/T6 X]
- EAC - Zone 20 Dust, [Ex iaD 20 T80° C X]
- EMC
- EN 61326 Emission (Group 1, Class B) & Interference Immunity (Industrial Application)
- Ex
- FM - Class I, Zone 0, AEx ia IIC
- FM - Dust Ignition-proof for Class II, III, Div. 2, Groups F, G
- FM - Hazardous Areas, Intrinsically Safe Class I, II & III, Div. 1, Grade A, B, C, D, E, F, G
- GL - Ships, Shipbuilding (e.g. Offshore)
- GOST
- IECEx - Hazardous Areas, Ex I, Zone 1 Gas, [Ex ia IIC T4/T5/T6 Gb]
- IECEx - Mining, [Ex ia I Ma]
- IECEx - Zone 0 Gas, [Ex ia IIA T4/T5/T6 Ga]
- IECEx - Zone 1 Mounting to Zone 0 Gas, [Ex ia IIC T4/T5/T6 Ga/Gb]
- IECEx - Zone 20 Dust, [Ex ia IIIC T120° C Da]
- INMETRO - Hazardous Areas, Ex I, Zone 1 Gas, [Ex ia IIC T4/T5/T6 Gb]
- INMETRO - Metrology, Measurement Technology
- INMETRO - Mining, [Ex ia I Ma]
- INMETRO - Zone 0 Gas, [Ex ia IIA T4/T5/T6 Ga]
- INMETRO - Zone 1 Mounting to Zone 0 Gas, [Ex ia IIC T4/T5/T6 Ga/Gb]
- INMETRO - Zone 20 Dust, [EX Ia IIIC T120° C Da]
- KazlnMetr
- UkrSEPRO
- UZSTANDARD
BSP Connection
- G 1/2” B Male
- G 1/4” Female Thread (Only in Hastelloy)
Cable Material
- FEP
- Polyurethane
Enclosure, Body Material
- 316L Stainless Steel
- Hastelloy
Environmental Protection
- IP68
Non-Linearity
- ≤ ± 0.2 % of Span
Output
- 4-20 mA, 2-Wire
Overpressure & Static Pressure Limits
- psi: 55 to 360 (kPa: 380 to 2.480, bar: 3.8 to 24.8)
Power Supply
- 10-30 Vdc
Pressure Range
- bar: 0 to 25
- Inches WC: 0 to 250
- kPa: 0 to 2,500
- psi: 0 to 300
Pressure Type
- Gauge
Repeatability
- Non-Repeatability: ≤ ± 0.1 % of Span
Storage Temperature
- -10° to 60° C (14° to 140° F)
Temperature Range
- -30° to 105° C (-22° to 221° F)
Wetted Materials
- 316L Stainless Steel
- FEP
- Hastelloy
- Polyurethane
Applications
Applications
- Wastewater treatment and biogas production
- Brackish water and fuel tanks in shipbuilding
- Oil and fuel storage tanks
- Mining and gas extraction