Images are representations only.

Pressure Transducer - TTF-1

Brand: WIKA Alexander Wiegand SE & Co. KG
The cylindrical measuring cell of the pressure transducer model TTF-1, as standard, is made from robust stainless steel and as a result exhibits high overpressure and burst pressure safety. for specific applications suitable materials are optionally available.
Features
  • Measuring ranges 0 ... 10 bar to 0 ... 1,000 bar. 
  • Non-linearity < 0.5 % of span. 
  • Wetted parts from stainless steel. 
  • Medium temperature -40 ... +125 °C. 
  • Output signal in mV/V. 
show more
The cylindrical measuring cell of the pressure transducer model TTF-1, as standard, is made from robust stainless steel and as a result exhibits high overpressure and burst pressure safety. for specific applications suitable materials are optionally available.
Features
  • Measuring ranges 0 ... 10 bar to 0 ... 1,000 bar. 
  • Non-linearity < 0.5 % of span. 
  • Wetted parts from stainless steel. 
  • Medium temperature -40 ... +125 °C. 
  • Output signal in mV/V. 

Specifications

Output Signals

  • Measuring Range [bar]
  • 0 to 10 1.4 to 2.6 mV/V
  • 0 to 16 and 0 to 25 1.5 to 2.5 mV/V
  • 0 to 40 up to 0 to 160 1.6 to 2.4 mV/V
  • 0 to 250 up to 0 to 1,000 1.7 to 2.3 mV/V

Power Supply

  • DC 6 ... 10 V

Temperature

  • 15° to 25° C

Atmospheric Pressure

  • 860 ... 1,060 mbar

Humidity

  • 45 ... 75 % Relative

Mounting Position

  • Any

Settling Time (10 ... 90 %)

  • < 1 millisecond

Zero Offset

  • Maximum ± 0.5 mV/V

Bridge Resistance

  • 6.5 ± 1.3 k Ω

Temperature Error

  • Zero Point: ± 0.1 % of Span/10 K
  • Span: ± 0.1 % of Span/10 K
  • Compensated Temperature Range: -40° to +100° C
  • Mean Temperature coefficient

Non-Linearity, Typical

  • 0 to 16 +0.40 % of Span
  • 0 to 25 +0.40 % of Span
  • 0 to 40 +0.35 % of Span
  • 0 to 60 +0.30 % of Span
  • 0 to 100 +0.25 % of Span
  • 0 to 160 +0.22 % of Span
  • 0 to 10 +0.50 % of Span
  • 0 to 250 +0.20 % of Span
  • 0 to 600 +0.15 % of Span
  • 0 to 1,000 +0.12 % of Span
  • 0 to 400 +0.18 % of Span
  • Measuring Range [bar]

Hysteresis

  • ≤ 0.1 % of Span

Long-term Stability

  • ≤ 0.2 % of Span/Year

Permissible Temperature Ranges

  • Medium: -40° to +125° C
  • Ambient: -40° to +100° C
  • Storage: -40° to +100° C

Service Life

  • > 100 million load cycles

Applications

  • Applications with limited mounting space
  • Hydraulic applications
  • Assembly for pressure transmitters, pressure switches and digital pressure gauges

Documentation