Wilcoxon’s side-exit 100 mV/g broadband sensor is ideal for monitoring machine vibration on a wide range of rotating equipment including motors, pumps, fans, compressors, turbines and generators. A 316L stainless steel casing provides rugged durability for the most extreme environments. The sensing element is housed in a case-isolated Faraday shield, providing maximum protection from ground loops and RF interference.
The 787A-D2 is classifed for usage in Class I Div. 2/Zone 2 locations where ignitable gases, vapors or liquids are handled, processed or used but are not usually present during normal operation and can only escape through accidental rupture, breakdown or leaks.
Features- Mounts in any orientation
- Hermetically sealed
- ESD-protected
- Reverse wiring protection
- Class I, Div 2/Zone 2 certified, non-incendive
- Manufactured in an approved ISO 9001 facility
Specifications
Specifications
Approvals & Certifications
- ATEX II 3 G Ex NA IIC T4 Gc -50° C ≤ Tamb ≤ 120° C
- CE
- CSA (C,US) Class I, Div. 2, Grade A, B, C, D, Class I, Zone 2 AEx, Ex NA II T4 Tamb: -50° to 120° C
Approvals & Certifications
- ISO 9001
Circuit Protection
- ESD Protection
- Reverse Wiring Protection
Electrical Connectors
- Cable (J9T2A / J9F)
- Output Connector: 2-Pin, MIL-C-5015 Style
Element
- Sensing Element Design: PZT, Shear
Enclosure, Body Material
- 316L Stainless Steel
Frequency
- Frequency Response (± 10 %): 1 to 5,000 Hz
- Frequency Response (± 3 dB): 0.5 to 10,000 Hz
- Resonance Frequency: 22 kHz
Mounting
- 1/4-28 Captive Hex Head Screw, 0.046” (1.168 mm) Diameter Safety Wire Hole
Mounting Position
- Any Orientation
Noise
- Electrical Noise, Equivalent G (Broadband: 2.5 Hz to 25 kHz): 700 µg
- Electrical Noise, Equivalent G (Spectral: 10 Hz): 10 µg/√Hz
- Electrical Noise, Equivalent G (Spectral: 100 to 1,000 Hz): 5 µg/√Hz
Non-Linearity
- Amplitude Non-Linearity: 1 %
Output Impedence
- Maximum 100 Ω
Power Requirement
- 18-30 Vdc
- Current Regulating Diode: 2-10 mA
Range
- Acceleration Range, Vdc > 25 V: 80 G Peak
Seal Type
- Hermetic
Sensitivity
- Base Strain Sensitivity, Max.
- Electromagnetic Sensitivity, Equivalent G, Max.
- Sensitivity, ± 5 %, 25° C (77° F): 100 mV/g
- Transverse Sensitivity: Max. 5 % of axial
Shock
- Shock Limit: 5,000 G Peak
Temperature Range
- -50° to 120° C (-58° to 248° F)
Vibration
- Vibration Limit: 500 G Peak
Voltage
- Bias Output Voltage: 12 Vdc