Images are representations only.

5500 Wire Rope Load Cell

Brand: Sensy - Sensors & Synergy S.A.
Load cell specially designed to measure the tension force on hoisting rope.
Features
  • CE certified for hoisting applications
  • Easy installation directly and without dismantling on the hoisting rope
  • Very large range of measured load on the cable (from 0.25 up to 24 tons)
  • Very large range of cable suitable (available diameters from 6 up to 46 mm)
  • Material: nickel plated steel (also available in stainless steel)
  • Protection IP 65
  • Sturdy design
  • Reliable and economical solution
  • Complete range of "CE" certified electronics and load limiters
  • Available options (non exhaustive list):
    • ATEX intrinsic safety Ex II 1GD Ex ia IIC T6 or T4 Ga Ex ia IIIC T80° C Da
    • High service temperature (180° C)
    • Amplified output (V or mA)
show more
Load cell specially designed to measure the tension force on hoisting rope.
Features
  • CE certified for hoisting applications
  • Easy installation directly and without dismantling on the hoisting rope
  • Very large range of measured load on the cable (from 0.25 up to 24 tons)
  • Very large range of cable suitable (available diameters from 6 up to 46 mm)
  • Material: nickel plated steel (also available in stainless steel)
  • Protection IP 65
  • Sturdy design
  • Reliable and economical solution
  • Complete range of "CE" certified electronics and load limiters
  • Available options (non exhaustive list):
    • ATEX intrinsic safety Ex II 1GD Ex ia IIC T6 or T4 Ga Ex ia IIIC T80° C Da
    • High service temperature (180° C)
    • Amplified output (V or mA)

Specifications

Applications

  • Hoisting Devices & Crane's Security in Combination with a Load Limitation Electronic: (BRIDGEBOY, CRANEBOY)

Approvals & Certifications

  • ATEX Intrinsic Safety Ex II 1 GD Ex ia IIC T6 or T4 Ga Ex ia IIIC T80° C Da
  • CE

Capacity

  • 0.25 to 24 T

Enclosure, Body Material

  • Nickel-Plated Steel
  • Stainless Steel

Environmental Protection

  • IP65

Excitation Voltage

  • 10 Vdc
  • 3-12 Vdc - Nominal Range

Insulation Resistance

  • > 5,000 megaohms

Load

  • Breaking Load: > 300 % of Full Scale
  • Permissible Dynamic Loading: 70 % of Full Scale

Load Limit

  • 200 % of Full Scale

Resistance

  • Input/Output: 352 ± 2 ohms

Sensitivity

  • ± 1 mV/V

Service Temperature

  • -30° to 70° C (-22° to 158° F)

Storage Temperature

  • -50° to 85° C (-58° to 185° F)

Temperature Coefficient

  • < ± 0.1 % of Full Scale/10° C (18° F)

Temperature Range

  • Nominal Temperature: -10° to 45° C (14° to 113° F)