Description
Wilcoxon’s HV series are innovative accelerometers designed for demanding applications requiring high electrical isolation between the sensor and machine. HV sensors are designed to withstand arcing between the sensor base and its internal electronics to levels as high as 6,000 volts. The sensors offer improved EMI-resistance in areas where high electromagnetic interference occurs such as wind turbines, railway systems and other high-voltage generators. The low frequency series has superior performance down to 0.1 Hz.
HV series sensors can pass a HiPot test of > 6,000 volts from sensor electronics to mounting base. This high isolation prevents energy from arcing through the sensor offering better protection of the associated equipment. Improvements in EFT and ESD resistance improves survivability during extreme transient events. The HV series come with a variety of mounting options to ensure compatibility with every application.
Features- Ultra low frequency sensors
- Ideal for power generation applications
- Rapid shock recovery
- Hermetically sealed
- Case-base isolation min 6 kV
- EMI-protected
- Manufactured in an approved ISO 9001 facility
Configure
Specifications
Specifications
Approvals & Certifications
- ISO 9001
Approvals & Certifications
- CE
Electrical Connectors
- Cable (J10 / J9T2A)
- Output Connector: 2-Pin MIL-5015 - Model HV200LF Series
- Output Connector: 4-Pin M12 - Model HV100LF Series
Element
- Sensing Element Design: PZT, Shear
Enclosure, Body Material
- Sensor Case: Stainless Steel
Frequency
- Frequency Response (± 10 %): 0.25 to 7,000 Hz
- Frequency Response (± 3 dB): 0.1 to 11,000 Hz
- Frequency Response (± 5 %): 0.35 to 5,000 Hz
- Resonance Frequency: 28 kHz
Input Impedance
- Impedance between Connector & Base (1.0 kHz): > 10 megaohms
- Impedance between Connector & Base (10 kHz): > 1 Megaohm
- Impedance between Connector & Base (100 Hz): > 100 megaohms
- Impedance between Connector & Base (DC): > 100 Gigaohms
Isolation
- Case-Base Isolation: Min. 6 kV
Mounting
- Integral Mounting: 1/4”-28 UNF - Model HV101LF, HV200LF, HV101LF-500 & HV200LF-500 Series
- Integral Mounting: M6 x 1.00 - Model HV102LF, HV202LF, HV102LF-500 & HV202LF-500 Series
- Integral Mounting: M8 x 1.25 - Model HV100LF, HV201LF, HV100LF-500 & HV201LF-500 Series
Noise
- Electrical Noise, Equivalent G (Spectral: 10 Hz): 10 µg/√Hz - Model LF Series
- Electrical Noise, Equivalent G (Spectral: 10 Hz): 3 µg/√Hz - Model LF-500 Series
- Electrical Noise, Equivalent G (Spectral: 100, 1,000 Hz): 2 µg/√Hz - Model LF-500 Series
- Electrical Noise, Equivalent G (Spectral: 100, 1,000 Hz): 5 µg/√Hz - Model LF Series
- Electrical Noise, Equivalent. G (Broadband: 2.5 Hz to 25 kHz): 250 µg - Model LF-500 Series
- Electrical Noise, Equivalent. G (Broadband: 2.5 Hz to 25 kHz): 400 µg - Model LF Series
Non-Linearity
- Amplitude Non-Linearity: 1 %
Output Impedence
- Maximum 100 to 300 Ω
Power Requirement
- 18-30 Vdc
- Current Regulating Diode: 2-10 mA
Range
- Acceleration Range, Vdc > 22 V: 10 G Peak - Model LF-500 Series
- Acceleration Range, Vdc > 22 V: 80 G Peak - Model LF Series
RFI/EMI Protection
- Yes
Seal Type
- Hermetic
Sensitivity
- Base Strain Sensitivity, Max. 0.0002 g/μstrain
- Electromagnetic Sensitivity, Equivalent G: Max. 70 µg/Gauss 70 µg/gauss
- Sensitivity, ± 5 %, 25° C (77° F): 100 mV/g - Model LF Series
- Sensitivity, ± 5 %, 25° C (77° F): 500 mV/g - Model LF-500 Series
- Transverse Sensitivity, Max. 5 % of axial
Shock
- Shock Limit: 5,000 G Peak
Temperature Range
- -50° to 120° C (-58° to 248° F)
Vibration
- Vibration Limit: 500 G Peak
Voltage
- Bias Output Voltage: 13 Vdc
- Dielectric Withstand Voltage between Connector & Surface: 5,000 Vac (1 Minute)