Images are representations only.

3110/3115 Heavy Compression Load Cell

Brand: Sensy - Sensors & Synergy S.A.
High capacity compression load cells.
Features
  • High capacity compression load cells
  • Material: nickel plated steel (3115) or stainless steel (3110)
  • Protection IP 65
  • Available options (non exhaustive list):
    • High service temperature (up to 180° C)
    • ATEX intrinsic safety Ex II 1GD Ex ia IIC T6 or T4 Ga Ex ia IIIC T80° C Da
    • Redundant dual Wheatstone bridge
    • Amplified (0-10 V, 4 to 20 mA) and digital output signal (RS-232C, RS-485, USB)
  • Also available as standard reference load cells following ISO 376 (EN10002/3) (Class "0.5" and "00"’)
show more
High capacity compression load cells.
Features
  • High capacity compression load cells
  • Material: nickel plated steel (3115) or stainless steel (3110)
  • Protection IP 65
  • Available options (non exhaustive list):
    • High service temperature (up to 180° C)
    • ATEX intrinsic safety Ex II 1GD Ex ia IIC T6 or T4 Ga Ex ia IIIC T80° C Da
    • Redundant dual Wheatstone bridge
    • Amplified (0-10 V, 4 to 20 mA) and digital output signal (RS-232C, RS-485, USB)
  • Also available as standard reference load cells following ISO 376 (EN10002/3) (Class "0.5" and "00"’)

Specifications

Accuracy

  • 0.05 % of Full Scale
  • 0.1 % of Full Scale
  • 0.25 % of Full Scale

Applications

  • Calibration Standards
  • Force Measurement
  • Process Control
  • Weighing

Approvals & Certifications

  • ATEX Intrinsic Safety Ex II 1 GD Ex ia IIC T6 or T4 Ga Ex ia IIIC T80° C Da
  • CE

Cable Length

  • 19 to 39 feet (6 to 12 metres)

Capacity

  • 30 KN to 30 MN

Communication

  • RS-232C
  • RS-485
  • USB

Electrical Connectors

  • Female/Male DIN 45322

Enclosure, Body Material

  • Nickel-Plated Steel (3115)
  • Stainless Steel (3110)

Environmental Protection

  • IP65

Excitation Voltage

  • 10 Vdc
  • 3-12 Vdc - Nominal Range

Insulation Resistance

  • > 5,000 megaohms at 50 V

Linearity

  • Error: < ± 0.25 % to < ± 0.04 % of Full Scale

Load

  • > 300 % of Full Scale - Breaking
  • 50 % of Full Scale - Dynamic Loading

Load Limit

  • 150 % of Full Scale

Operating Temperature

  • 180° C (356° F) - High Service Temperature

Repeatability

  • Error: < ± 0.1 % to < ± 0.02 % of Full Scale

Resistance

  • Input/Output: 350 to 702 ± 2 ohms

Sensitivity

  • < ± 0.3 % - Tolerance
  • 1.5 mV/V

Service Temperature

  • -30° to 70° C (-22° to 158° F)

Static Lateral Force

  • 15 % of Full Scale

Storage Temperature

  • -50° to 85° C (-58° to 185° F)

Temperature Coefficient

  • < ± 0.03 % of Full Scale/10° C (18° F) - Zero Signal
  • < ± 0.035 % of Full Scale/10° C (18° F) - Sensitivity, Zero Signal
  • < ± 0.05 % of Full Scale/10° C (18° F) - Sensitivity

Temperature Range

  • -10° to 45° C (14° to 113° F) - Nominal

Zero Balance

  • ± 0.02 mV/V