Images are representations only.

5100L/5105L Tension Load Cell

Brand: Sensy - Sensors & Synergy S.A.
Tension load cells combining sturdiness and easiness to install.
Features
  • Wide range of capacities: 2 t up to 100 t
  • Easy to install, compact design
  • Protection IP 66
  • Material: stainless steel (5100L), nickel plated steel (5105L)
  • Available options:
    • High service temperature (up to 180° C)
    • ATEX intrinsic safety Ex II 1GD Ex ia IIC T6 or T4 Ga Ex ia IIIC T80° C Da
    • Protection IP 68 or special for marine environment
    • Amplified output (V or mA) and digital output signal (RS-232C, RS-485, USB)
show more
Tension load cells combining sturdiness and easiness to install.
Features
  • Wide range of capacities: 2 t up to 100 t
  • Easy to install, compact design
  • Protection IP 66
  • Material: stainless steel (5100L), nickel plated steel (5105L)
  • Available options:
    • High service temperature (up to 180° C)
    • ATEX intrinsic safety Ex II 1GD Ex ia IIC T6 or T4 Ga Ex ia IIIC T80° C Da
    • Protection IP 68 or special for marine environment
    • Amplified output (V or mA) and digital output signal (RS-232C, RS-485, USB)

Specifications

Applications

  • Force Measuring on Rigging
  • Towing Force Measurement (Marine)
  • Weighing of Hanging Load

Approvals & Certifications

  • ATEX Intrinsic Safety Ex II 1 GD Ex ia IIC T6 or T4 Ga Ex ia IIIC T80° C Da
  • CE

Cable Length

  • 10 to 39 feet (3 to 12 metres)

Capacity

  • 2 to 100 T

Communication

  • RS-232C, RS-485
  • USB

Electrical Connectors

  • DIN 45322

Enclosure, Body Material

  • Nickel-Plated Steel
  • Stainless Steel

Environmental Protection

  • IP66
  • IP68

Excitation Voltage

  • 10 Vdc

Insulation Resistance

  • > 5,000 megaohms

Linearity

  • Error: < ± 0.25 % (0.25 Model) to < ± 1 % (SL-HOIST) of Full Scale

Load

  • > 300 % to > 500 % of Full Scale - Breaking Load

Load Limit

  • 150 % to 200 % of Full Scale

Repeatability

  • Error: < ± 0.1 % (0.25 Model) to < ± 0.25 % (SL-HOIST Model) of Full Scale

Resistance

  • Input/Output: 352 ± 2 ohms

Sensitivity

  • Nominal Sensitivity: 1 to 1.5 mV/V
  • Tolerance: < ± 0.3 % to < ± 0.5 %

Service Temperature

  • -30° to 70° C (-22° to 158° F)

Static Lateral Force

  • 10 % to 150 % of Full Scale

Storage Temperature

  • -50° to 85° C (-58° to 185° F)

Temperature Coefficient

  • < ± 0.035 % of Full Scale/10° C (18° F)
  • < ± 0.05 % of Full Scale/10° C (18° F)
  • < ± 0.2 % of Full Scale/10° C (18° F)

Zero Balance

  • ± 0.02 mV/V