Images are representations only.

3100P Pendular Compression Load Cell

Brand: Sensy - Sensors & Synergy S.A.
Features:
  • Canister, high capacity load cell (up to 500 tons)
  • Stainless steel
  • Protection IP 67
  • Pendular technology
  • Self restoring
  • Available in C.5 (1,500 d) OIML / R 60
  • Matched impedance and sensitivity (for parallel connection)
  • Cable length: 12m (500 t: 20m)
  • Available options (non exhaustive list):
    • ATEX intrinsic safety Ex II 1GD Ex ia IIC T6 or T4 Ga Ex ia IIIC T80° C Da
    • High service temperature (up to180° C)
    • Protection IP 68
show more
Features:
  • Canister, high capacity load cell (up to 500 tons)
  • Stainless steel
  • Protection IP 67
  • Pendular technology
  • Self restoring
  • Available in C.5 (1,500 d) OIML / R 60
  • Matched impedance and sensitivity (for parallel connection)
  • Cable length: 12m (500 t: 20m)
  • Available options (non exhaustive list):
    • ATEX intrinsic safety Ex II 1GD Ex ia IIC T6 or T4 Ga Ex ia IIIC T80° C Da
    • High service temperature (up to180° C)
    • Protection IP 68

Specifications

Accuracy

  • 0.1 % of Full Scale
  • 0.25 % of Full Scale
  • 1,500 D OIML (C 1.5)

Applications

  • Hoppers
  • Reactors
  • Silos
  • Tanks
  • Train Scales
  • Weighbridges

Approvals & Certifications

  • C 1.5 (1,500 D) OIML/R 60

Approvals & Certifications

  • ATEX Intrinsic Safety Ex II 1 GD Ex ia IIC T6 or T4 Ga Ex ia IIIC T80° C Da
  • CE

Capacity

  • 3 to 500 T

Enclosure, Body Material

  • Stainless Steel

Environmental Protection

  • IP67
  • IP68

Excitation Voltage

  • 10 Vdc

Insulation Resistance

  • > 5,000 megaohms

Linearity

  • Error: < ± 0.25 % of Full Scale to < ± 0.03 % of Full Scale

Load Limit

  • 150 % of Full Scale

Operating Temperature

  • Optional High Service Temperature: 180° C (356° F)

Repeatability

  • Error: < ± 0.1 % of Full Scale to < ± 0.015 % of Full Scale

Resistance

  • Input/Output: 350 to 702 ± 2 ohms

Sensitivity

  • 1.5 mV/V
  • Tolerance: < ± 0.2 % to < ± 0.3 %

Service Temperature

  • -30° to 70° C (-22° to 158° F)

Storage Temperature

  • -50° to 85° C (-58° to 185° F)

Temperature Coefficient

  • < ± 0.017 % of Full Scale/10° C (18° F)
  • < ± 0.025 % of Full Scale/10° C (18° F)
  • < ± 0.035 % of Full Scale/10° C (18° F)
  • < ± 0.05 % of Full Scale/10° C (18° F)

Zero Balance

  • ± 0.02 mV/V