Model TR34 Miniature Resistance Thermometer

Brand: WIKA Alexander Wiegand SE & Co. KG
Resistance thermometers of this series are used as universal thermometers for the measurement of liquid and gaseous media in the range -50 ... +250 °C [-58 ... +482 °F]. The instruments are Intrinsically-Safe and suitable for use in hazardous areas.
Features
  • Intrinsically-Safe Ex i version, very compact design, high vibration resistance and fast response time
  • With direct sensor output (Pt100, Pt1000 in 2-, 3- or 4-wire connection) or integrated transmitter with 4 ... 20 mA output signal
  • Integrated transmitter is individually parameterisable with free-of-charge WIKAsoft-TT PC configuration software
  • Sensor element with accuracy class A in accordance with IEC 60751
Resistance thermometers of this series are used as universal thermometers for the measurement of liquid and gaseous media in the range -50 ... +250 °C [-58 ... +482 °F]. The instruments are Intrinsically-Safe and suitable for use in hazardous areas.
Features
  • Intrinsically-Safe Ex i version, very compact design, high vibration resistance and fast response time
  • With direct sensor output (Pt100, Pt1000 in 2-, 3- or 4-wire connection) or integrated transmitter with 4 ... 20 mA output signal
  • Integrated transmitter is individually parameterisable with free-of-charge WIKAsoft-TT PC configuration software
  • Sensor element with accuracy class A in accordance with IEC 60751

Specifications

Temperature Range

  • Class A: without Neck Tube -30° to +150° C (-22° to +302° F), with Neck Tube -30° to +250° C (-22° to +482° F)
  • Class B: without Neck Tube -50° to +150° C (-58° to +302° F), with Neck Tube -50° to +250° C (-58° to +482° F)

Temperature at the Connector

  • Maximum 85° C (185° F)

Measuring Element

  • Pt100 (Measuring Current: 0.1 ... 1.0 mA)
  • Pt1000 (Measuring Current: 0.1 ... 0.3 mA)

Connection Method

  • 2-Wire The lead resistance is recorded as an error in the measurement
  • 3-Wire with a cable length of 30 m or longer, measuring deviations can occur

Tolerance Value of the Measuring Element Per IEC 60751

  • Class A
  • Class B at 2-Wire

Electrical Connection

  • M12 x 1 Circular Connector (4-Pin)

Material of Wetted Parts

  • Stainless Steel 1.4571

Explosion Protection

  • Intrinsically safe to Ex i (ATEX) gas/dust (For further information see “Further Specifications for explosion-protected version”)

Applications

  • Machine building, plant and vessel construction
  • Propulsion technology, hydraulics