Images are representations only.

5205L Tension Load Cell

Brand: Sensy - Sensors & Synergy S.A.
Tension load cell specially designed for load limitation on hoisting devices.
Features
  • Sturdy design
  • Breaking load > 500%
  • CE certified for hoisting devices
  • Material: nickel plated steel
  • Protection IP 66
  • Easy to install (standard shackles)
  • Cable length:
    • 0.5 to 5 t: 3 m
    • 10 to 25 t: 6 m
  • Complete range of "CE" certified electronics and load limiters
  • Available options:
    • ATEX intrinsic safety Ex II 1GD Ex ia IIC T6 or T4 Ga Ex ia IIIC T80° C Da
    • Amplified output (V or mA)
show more
Tension load cell specially designed for load limitation on hoisting devices.
Features
  • Sturdy design
  • Breaking load > 500%
  • CE certified for hoisting devices
  • Material: nickel plated steel
  • Protection IP 66
  • Easy to install (standard shackles)
  • Cable length:
    • 0.5 to 5 t: 3 m
    • 10 to 25 t: 6 m
  • Complete range of "CE" certified electronics and load limiters
  • Available options:
    • ATEX intrinsic safety Ex II 1GD Ex ia IIC T6 or T4 Ga Ex ia IIIC T80° C Da
    • Amplified output (V or mA)

Specifications

Applications

  • SL - HOIST: Hoisting Devices & Crane Security in Combination with a Load Limitation Eelectronic: (BRIDGEBOY, CRANEBOY)
  • SL - LIFT: Load Limitations for Lifts

Approvals & Certifications

  • ATEX Intrinsic Safety Ex II 1 GD Ex ia IIC T6 or T4 Ga Ex ia IIIC T80° C Da
  • CE

Cable Length

  • 10 to 20 feet (3 to 6 metres)

Capacity

  • 0.5 to 25 T

Electrical Connectors

  • DIN 45322

Enclosure, Body Material

  • Nickel-Plated Steel

Environmental Protection

  • IP66

Excitation Voltage

  • 10 Vdc
  • 3-12 Vdc - Nominal Range

Insulation Resistance

  • > 5,000 megaohms

Linearity

  • Error: < ± 1 % of Full Scale

Load

  • > 1000 % of Full Scale - Breaking Load (SL-LIFT)
  • > 500 % of Full Scale - Breaking Load (SL-HOIST)

Load Limit

  • 200 % to 300 % of Full Scale

Resistance

  • Input/Output: 352 ± 2 ohms

Sensitivity

  • Nominal Sensitivity: 0.5 to 1 mV/V

Service Temperature

  • -30° to 70° C (-22° to 158° F)

Static Lateral Force

  • 150 % of Full Scale
  • 200 % of Full Scale

Storage Temperature

  • -50° to 85° C (-58° to 185° F)

Temperature Coefficient

  • < ± 0.2 % of Full Scale/10° C (18° F)

Zero Balance