Images are representations only.

Kayden CLASSIC 810 Thermal Flow, Level & Interface Switch

Brand: Kayden Instruments
Does not ship to OH, United States
The Kayden CLASSIC 810 Flow, Level, Interface Switch & Transmitter features a precision-welded, highly accurate stainless steel sensor. Alarms and trip-points are field-configurable for flow, temperature, high or low, hysteresis, time delay, and more.
 
Ideal for liquids, gases, and slurries in a clean or dirty process, the CLASSIC 810 is available in a wide range of thread sizes and insertion lengths. Kayden's electronic thermal dispersion flow and level switches have no moving parts to foul, clog, or stick, resulting in exceptional reliability and requiring little to no maintenance.
 
With no moving parts and minimal invasiveness, Kayden's thermal flow and level switches provide a highly repeatable, accurate, low cost of ownership, long life, and easy-to-install solution for demanding air, gas, liquid, and slurry applications.
 
All Kayden® CLASSIC® models feature a rugged flameproof enclosure with blind or glass lens covers. Kayden’s advanced digital electronics will streamline the way you monitor and control your process. 
 
  • Process Connections - Male NPT
    • 1/2"
    • 3/4"
    • 1"
    • 1-1/4"
    • 1-1/2"
    • 2"
  • Adjustable Set Point Range
    • 0 - 254  feet/s   
    •  0 - 77    meters/s 
  • Insertion 'U' Lengths
    • 1.2"  (3.0 cm)
    • 2"  (5.0 cm)
    • 3"  (7.5 cm)
    • 4"  (10.1 cm)
    • 6"  (15.2 cm)
    • 9"  (22.8 cm)
    • 12"  (30.4 cm)
    • 18"  (45.7 cm)
    • Custom Lengths from 2.5" to 120" (6.0 cm to 305 cm) by 1/2" (1 cm) increments
  • Input/Supply Power
    • 12-24 Vdc & 120-240 Vac, 50-60 Hz
  • Operating Pressure Maximum
    • CSA - Canadian Standards Association
      • psi   3,480
      • kPa  24,000
      • bar  240
    • CRN - Canadian Registration Number 0F22124.2C for 316/316L Stainless Steel
      • psi   1,990
      • kPa  13,721
      • bar  137.2
  • Temperature Range Sensor
    • -55° to 200° C
    • -67° to 392° F
  • Local Enclosure
    • Aluminum
    • 1" Female NPT
    • Hazardous Areas
  • Local Enclosure Cover
    • Blind or Glass Lens
    • Hazardous Areas
  • Wetted Materials
    • 316/316L Stainless Steel
    • Titanium
    • Hastelloy C-276
  • Outputs/Communications
    • Two Independent Relays - SPDT
    • 4-20 mA
    • Modbus
    • Rated 120 Vac max, 30 Vdc max, 4 A max
  • Approvals
    • CSA
    • CRN
    • Single Seal
    • NACE
    • ASME BPVC Sec. VIII Div. 1
    • NEMA 4, 4X, 6P, IP65/67
Features
  • Detects minimum flow and the presence and absence of flow
  • Temperature compensation to provide repeatable alarm under varying process temperatures
  • Continuous diagnostics detect sensor fault
  • Non-linear mA output signal can be used for trending, diagnostics, repeatable flow and level indication
  • Simple calibration and installation
  • Excellent low-flow sensitivity
  • Window to view alarm status
  • Integral or remote electronics
  • NACE construction
The Kayden CLASSIC 810 Flow, Level, Interface Switch & Transmitter features a precision-welded, highly accurate stainless steel sensor. Alarms and trip-points are field-configurable for flow, temperature, high or low, hysteresis, time delay, and more.
 
Ideal for liquids, gases, and slurries in a clean or dirty process, the CLASSIC 810 is available in a wide range of thread sizes and insertion lengths. Kayden's electronic thermal dispersion flow and level switches have no moving parts to foul, clog, or stick, resulting in exceptional reliability and requiring little to no maintenance.
 
With no moving parts and minimal invasiveness, Kayden's thermal flow and level switches provide a highly repeatable, accurate, low cost of ownership, long life, and easy-to-install solution for demanding air, gas, liquid, and slurry applications.
 
All Kayden® CLASSIC® models feature a rugged flameproof enclosure with blind or glass lens covers. Kayden’s advanced digital electronics will streamline the way you monitor and control your process. 
 
  • Process Connections - Male NPT
    • 1/2"
    • 3/4"
    • 1"
    • 1-1/4"
    • 1-1/2"
    • 2"
  • Adjustable Set Point Range
    • 0 - 254  feet/s   
    •  0 - 77    meters/s 
  • Insertion 'U' Lengths
    • 1.2"  (3.0 cm)
    • 2"  (5.0 cm)
    • 3"  (7.5 cm)
    • 4"  (10.1 cm)
    • 6"  (15.2 cm)
    • 9"  (22.8 cm)
    • 12"  (30.4 cm)
    • 18"  (45.7 cm)
    • Custom Lengths from 2.5" to 120" (6.0 cm to 305 cm) by 1/2" (1 cm) increments
  • Input/Supply Power
    • 12-24 Vdc & 120-240 Vac, 50-60 Hz
  • Operating Pressure Maximum
    • CSA - Canadian Standards Association
      • psi   3,480
      • kPa  24,000
      • bar  240
    • CRN - Canadian Registration Number 0F22124.2C for 316/316L Stainless Steel
      • psi   1,990
      • kPa  13,721
      • bar  137.2
  • Temperature Range Sensor
    • -55° to 200° C
    • -67° to 392° F
  • Local Enclosure
    • Aluminum
    • 1" Female NPT
    • Hazardous Areas
  • Local Enclosure Cover
    • Blind or Glass Lens
    • Hazardous Areas
  • Wetted Materials
    • 316/316L Stainless Steel
    • Titanium
    • Hastelloy C-276
  • Outputs/Communications
    • Two Independent Relays - SPDT
    • 4-20 mA
    • Modbus
    • Rated 120 Vac max, 30 Vdc max, 4 A max
  • Approvals
    • CSA
    • CRN
    • Single Seal
    • NACE
    • ASME BPVC Sec. VIII Div. 1
    • NEMA 4, 4X, 6P, IP65/67
Features
  • Detects minimum flow and the presence and absence of flow
  • Temperature compensation to provide repeatable alarm under varying process temperatures
  • Continuous diagnostics detect sensor fault
  • Non-linear mA output signal can be used for trending, diagnostics, repeatable flow and level indication
  • Simple calibration and installation
  • Excellent low-flow sensitivity
  • Window to view alarm status
  • Integral or remote electronics
  • NACE construction
Models matching criteria: 47
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 3/4" NPT, 6"U, SST, Blind, CRN view more
  • Process Connection: 3/4" MNPT
  • Insertion 'U' Length: 6"
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Temperature Ranges
    • Sensor: -55°C to 200°C (-58°F to 392°F)
    • Electronics: -55°C to 65°C (-67°F to 149°F)
  • Local Enclosure: Aluminum Flameproof, 1" FNPT
  • Cover: Flameproof Blind Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials
    • Standard: 316/316L Stainless Steel
  • Outputs/Communications
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable)
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)
  • Electronics - Standard Features
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)
    • Start-Up Bypass Timer
  • c CSA us (UL Standards), CRN (Canada-wide), Single Seal, NACE, NEMA 4X
Add-Ons Stainless Steel Tag
In Stock 1 - 5 days
$1,523.96 USD
Does not ship to OH, United States
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1" NPT, 2"U, SST, Blind, CSA view more
  • Process Connection: 1" MNPT
  • Insertion 'U' Length: 2"
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Temperature Ranges
    • Sensor: -55°C to 200°C (-58°F to 392°F)
    • Electronics: -55°C to 65°C (-67°F to 149°F)
  • Local Enclosure: Aluminum Flameproof, 1" FNPT
  • Cover: Flameproof Blind Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials
    • Standard: 316/316L Stainless Steel
  • Outputs/Communications
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable)
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)
  • Electronics - Standard Features
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)
    • Start-Up Bypass Timer
  • c CSA us (UL Standards), Single Seal, NACE, NEMA 4X
Add-Ons Stainless Steel Tag
In Stock 2 - 5 days
$1,383.53 USD
Does not ship to OH, United States
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 3/4" NPT, 2"U, SST, Blind, CRN/CSA view more
  • Process Connection: 3/4" MNPT
  • Insertion 'U' Length: 2"
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Temperature Ranges
    • Sensor: -55°C to 200°C (-58°F to 392°F)
    • Electronics: -55°C to 65°C (-67°F to 149°F)
  • Local Enclosure: Aluminum Flameproof, 1" FNPT
  • Cover: Flameproof Blind Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials
    • Standard: 316/316L Stainless Steel
  • Outputs/Communications
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable)
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)
  • Electronics - Standard Features
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)
    • Start-Up Bypass Timer
  • c CSA us (UL Standards), CRN (Canada-wide), Single Seal, NACE, NEMA 4X
Add-Ons Stainless Steel Tag
In Stock 1 - 5 days
$1,383.53 USD
Does not ship to OH, United States
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 4"U, SST, Blind, CRN view more
  • Process Connection: 1/2" MNPT
  • Insertion 'U' Length: 4"
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Temperature Ranges
    • Sensor: -55°C to 200°C (-58°F to 392°F)
    • Electronics: -55°C to 65°C (-67°F to 149°F)
  • Local Enclosure: Aluminum Flameproof, 1" FNPT
  • Cover: Flameproof Blind Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials
    • Standard: 316/316L Stainless Steel
  • Outputs/Communications
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable)
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)
  • Electronics - Standard Features
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)
    • Start-Up Bypass Timer
  • c CSA us (UL Standards), CRN (Canada-wide), Single Seal, NACE, NEMA 4X
Add-Ons Stainless Steel Tag
In Stock 1 - 5 days
$1,453.74 USD
Does not ship to OH, United States
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1" NPT, 2"U, SST, Lens, CSA view more
  • Process Connection: 1" MNPT
  • Insertion 'U' Length: 2"
  • Adjustable Set Point Range
    • 0 - 254 feet/s
    • 0 - 77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Temperature Ranges
    • Sensor
      • -55°C to 200°C
      • -58°F to 392°F
    • Electronics
      • -55°C to 65°C
      • -67°F to 149°F
  • Local Enclosure: Aluminum Flameproof, 1" FNPT
  • Cover: Flameproof Glass Lens Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials
    • Standard: 316/316L Stainless Steel
  • Outputs/Communications:
    • Two Independent Relays - SPDT
    • 4-20 mA (Thermal Signal, Scalable) 
    • Modbus Communication via RS-485
    • RCMS - Remote Control & Monitoring Software
  • Electronics - Standard Features
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation, Flow/Level
    • Start-Up Bypass Timer
  • c CSA us (UL Standards), Single Seal, NACE, NEMA 4X
Add-Ons Stainless Steel Tag
In Stock 2 - 5 days
$1,558.73 USD
Does not ship to OH, United States
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1" NPT, 2"U, SST, Lens, CRN view more
  • Process Connection: 1" MNPT
  • Insertion 'U' Length: 2"
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Temperature Ranges
    • Sensor: -55°C to 200°C (-58°F to 392°F)
    • Electronics: -55°C to 65°C (-67°F to 149°F)
  • Local Enclosure: Aluminum Flameproof, 1" FNPT
  • Cover: Flameproof Glass Lens Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials
    • Standard: 316/316L Stainless Steel
  • Outputs/Communications
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable)
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)
  • Electronics - Standard Features
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)
    • Start-Up Bypass Timer
  • c CSA us (UL Standards), CRN (Canada-wide), Single Seal, NACE, NEMA 4X
Add-Ons Stainless Steel Tag
In Stock 2 - 5 days
$1,558.73 USD
Does not ship to OH, United States
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 2"U, SST, Lens, CRN/CSA view more
  • Process Connection: 1/2" MNPT
  • Insertion 'U' Length: 2"
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Temperature Ranges
    • Sensor: -55°C to 200°C (-58°F to 392°F)
    • Electronics: -55°C to 65°C (-67°F to 149°F)
  • Local Enclosure: Aluminum Flameproof, 1" FNPT
  • Cover: Flameproof Glass Lens Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials
    • Standard: 316/316L Stainless Steel
  • Outputs/Communications
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable)
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)
  • Electronics - Standard Features
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)
    • Start-Up Bypass Timer
  • c CSA us (UL Standards), CRN (Canada-wide), Single Seal, NACE, NEMA 4X
Add-Ons Stainless Steel Tag
In Stock 1 - 5 days
$1,558.73 USD
Does not ship to OH, United States
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 3/4" NPT, 2"U, SST, Lens, CRN view more
  • Process Connection: 3/4" MNPT
  • Insertion 'U' Length: 2"
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Temperature Ranges
    • Sensor: -55°C to 200°C (-58°F to 392°F)
    • Electronics: -55°C to 65°C (-67°F to 149°F)
  • Local Enclosure: Aluminum Flameproof, 1" FNPT
  • Cover: Flameproof Glass Lens Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials
    • Standard: 316/316L Stainless Steel
  • Outputs/Communications
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable)
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)
  • Electronics - Standard Features
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)
    • Start-Up Bypass Timer
  • c CSA us (UL Standards), CRN (Canada-wide), Single Seal, NACE, NEMA 4X
Add-Ons Stainless Steel Tag
In Stock 1 - 5 days
$1,558.73 USD
Does not ship to OH, United States
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1" NPT, 9"U, SST, Blind, CSA view more
  • Process Connection: 1" MNPT
  • Insertion 'U' Length: 9"
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Temperature Ranges
    • Sensor: -55°C to 200°C (-58°F to 392°F)
    • Electronics: -55°C to 65°C (-67°F to 149°F)
  • Local Enclosure: Aluminum Flameproof, 1" FNPT
  • Cover: Flameproof Blind Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials
    • Standard: 316/316L Stainless Steel
  • Outputs/Communications
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable)
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)
  • Electronics - Standard Features
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)
    • Start-Up Bypass Timer
  • c CSA us (UL Standards), Single Seal, NACE, NEMA 4X
Add-Ons Stainless Steel Tag
In Stock 2 - 5 days
$1,628.94 USD
Does not ship to OH, United States
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 1.2"U, SST, Blind, CSA view more
810 Threaded
R:  Sensor Temperature Range  -55°C to +200°C (-58°F to +392°F) Continuous Service
A:  Sensor Material  316/316L Stainless Steel
C:  Process Connection  1/2"
0012:  Insertion "U" Length  1.2"
C:  Input Power  12-24 VDC and 115-230 VAC, 50-60 Hz
1:  Local Enclosure  Aluminum Flameproof, 1" FNPT
B:  Cover for Local Enclosure  Flameproof Blind Cover
0A:  Remote Electronics Enclosure & Cover  Not Required
1:  Agency Approvals  c CSA us (UL Standards), Single Seal, NACE, NEMA 4X
E: Language  English
Electronics Temperature Range  -55°C to 65°C (-67°F to 149°F)
Operating Pressure - Maximum   Per Flange Rating (to a max of 1990 psi), ASME B16.5
Outputs/Communications
  • Two Independent Relays (SPDT)
  • 4-20 mA (Thermal Signal, Scalable)
  • Modbus Communication via RS-485
  • RCMS (Remote Control & Monitoring Software)
Electronics - Standard Features
  • Automated Redundant Self-Test Diagnostics
  • Display Panel Lock-Out
  • Easy Set-up
  • No Mechanical Jumpers or Trim Pots
  • Intelligent Push Button Interface
  • Constant Display of Operation (Flow/Level)
  • Start-Up Bypass Timer
Add-Ons Stainless Steel Tag
In Stock 1 - 5 days
$1,383.53 USD
Does not ship to OH, United States
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 3/4" NPT, 3"U, SST, Blind, CRN view more
  • Process Connection: 3/4" MNPT
  • Insertion 'U' Length: 3"
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Temperature Ranges
    • Sensor: -55°C to 200°C (-58°F to 392°F)
    • Electronics: -55°C to 65°C (-67°F to 149°F)
  • Local Enclosure: Aluminum Flameproof, 1" FNPT
  • Cover: Flameproof Blind Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials
    • Standard: 316/316L Stainless Steel
  • Outputs/Communications
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable)
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)
  • Electronics - Standard Features
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)
    • Start-Up Bypass Timer
  • c CSA us (UL Standards), CRN (Canada-wide), Single Seal, NACE, NEMA 4X
Add-Ons Stainless Steel Tag
In Stock 1 - 5 days
$1,418.98 USD
Does not ship to OH, United States
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 3/4" NPT, 1.2"U, SST, Lens, CSA view more
  • Process Connection: 3/4" MNPT
  • Insertion 'U' Length: 1.2"
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Temperature Ranges
    • Sensor: -55°C to 200°C (-58°F to 392°F)
    • Electronics: -55°C to 65°C (-67°F to 149°F)
  • Local Enclosure: Aluminum Flameproof, 1" FNPT
  • Cover: Flameproof Glass Lens Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials
    • Standard: 316/316L Stainless Steel
  • Outputs/Communications
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable)
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)
  • Electronics - Standard Features
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)
    • Start-Up Bypass Timer
  • c CSA us (UL Standards), Single Seal, NACE, NEMA 4X
Add-Ons Stainless Steel Tag
In Stock 1 - 5 days
$1,558.73 USD
Does not ship to OH, United States
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 3/4" NPT, 1.2"U, SST, Lens, CRN view more
  • Process Connection: 3/4" MNPT
  • Insertion 'U' Length: 1.2"
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Temperature Ranges
    • Sensor: -55°C to 200°C (-58°F to 392°F)
    • Electronics: -55°C to 65°C (-67°F to 149°F)
  • Local Enclosure: Aluminum Flameproof, 1" FNPT
  • Cover: Flameproof Glass Lens Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials
    • Standard: 316/316L Stainless Steel
  • Outputs/Communications
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable)
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)
  • Electronics - Standard Features
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)
    • Start-Up Bypass Timer
  • c CSA us (UL Standards), CRN (Canada), Single Seal, NACE, NEMA 4X
Add-Ons Stainless Steel Tag
In Stock 1 - 5 days
$1,558.73 USD
Does not ship to OH, United States
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1" NPT, 3"U, SST, Lens, CRN view more
  • Process Connection: 1" MNPT
  • Insertion 'U' Length: 3"
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Temperature Ranges
    • Sensor: -55°C to 200°C (-58°F to 392°F)
    • Electronics: -55°C to 65°C (-67°F to 149°F)
  • Local Enclosure: Aluminum Flameproof, 1" FNPT
  • Cover: Flameproof Glass Lens Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials
    • Standard: 316/316L Stainless Steel
  • Outputs/Communications
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable)
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)
  • Electronics - Standard Features
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)
    • Start-Up Bypass Timer
  • c CSA us (UL Standards), CRN (Canada-wide), Single Seal, NACE, NEMA 4X
Add-Ons Stainless Steel Tag
In Stock 2 - 5 days
$1,594.18 USD
Does not ship to OH, United States
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 3/4" NPT, 3"U, SST, Lens, CSA view more
  • Process Connection: 3/4" MNPT
  • Insertion 'U' Length: 3"
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Temperature Ranges
    • Sensor: -55°C to 200°C (-58°F to 392°F)
    • Electronics: -55°C to 65°C (-67°F to 149°F)
  • Local Enclosure: Aluminum Flameproof, 1" FNPT
  • Cover: Flameproof Glass Lens Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials
    • Standard: 316/316L Stainless Steel
  • Outputs/Communications
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable)
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)
  • Electronics - Standard Features
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)
    • Start-Up Bypass Timer
  • c CSA us (UL Standards), Single Seal, NACE, NEMA 4X
Add-Ons Stainless Steel Tag
In Stock 1 - 5 days
$1,594.18 USD
Does not ship to OH, United States
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1" NPT, 2"U, SST, Blind, CRN view more
  • Process Connection: 1" MNPT
  • Insertion 'U' Length: 2"
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Temperature Ranges
    • Sensor: -55°C to 200°C (-58°F to 392°F)
    • Electronics: -55°C to 65°C (-67°F to 149°F)
  • Local Enclosure: Aluminum Flameproof, 1" FNPT
  • Cover: Flameproof Blind Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials
    • Standard: 316/316L Stainless Steel
  • Outputs/Communications
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable)
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)
  • Electronics - Standard Features
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)
    • Start-Up Bypass Timer
  • c CSA us (UL Standards), CRN (Canada-wide), Single Seal, NACE, NEMA 4X
Add-Ons Stainless Steel Tag
In Stock 2 - 5 days
$1,383.53 USD
Does not ship to OH, United States
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 2"U, SST, Blind, CRN view more
  • Process Connection: 1/2" MNPT
  • Insertion 'U' Length: 2"
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Temperature Ranges
    • Sensor: -55°C to 200°C (-58°F to 392°F)
    • Electronics: -55°C to 65°C (-67°F to 149°F)
  • Local Enclosure: Aluminum Flameproof, 1" FNPT
  • Cover: Flameproof Blind Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials
    • Standard: 316/316L Stainless Steel
  • Outputs/Communications
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable)
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)
  • Electronics - Standard Features
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)
    • Start-Up Bypass Timer
  • c CSA us (UL Standards), CRN (Canada-wide), Single Seal, NACE, NEMA 4X
Add-Ons Stainless Steel Tag
In Stock 1 - 5 days
$1,383.53 USD
Does not ship to OH, United States
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1" NPT, 1.2"U, SST, Lens, CRN/CSA view more
  • Process Connection: 1" MNPT
  • Insertion 'U' Length: 1.2"
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Adjustable Set Point Range in Hydrocarbon: 0-5 feet/sec, 1.5 meters/sec
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Temperature Ranges
    • Sensor: -55°C to 200°C (-58°F to 392°F)
    • Electronics: -55°C to 65°C (-67°F to 149°F)
  • Local Enclosure: Aluminum Flameproof, 1" FNPT
  • Cover: Flameproof Glass Lens Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials
    • Standard: 316/316L Stainless Steel
  • Outputs/Communications
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable)
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)
  • Electronics - Standard Features
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)
    • Start-Up Bypass Timer
  • CSA us (UL Standards), CRN (Canada-wide), Single Seal, NACE, NEMA 4X
Add-Ons Stainless Steel Tag
In Stock 2 - 5 days
$1,558.73 USD
Does not ship to OH, United States
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 3/4" NPT, 2"U, SST, Lens, CSA view more
  • Process Connection: 3/4" MNPT
  • Insertion 'U' Length: 2"
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Temperature Ranges
    • Sensor: -55°C to 200°C (-58°F to 392°F)
    • Electronics: -55°C to 65°C (-67°F to 149°F)
  • Local Enclosure: Aluminum Flameproof, 1" FNPT
  • Cover: Flameproof Glass Lens Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials
    • Standard: 316/316L Stainless Steel
  • Outputs/Communications
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable)
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software) Downloadable from Kayden.com
  • Electronics - Standard Features
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)
    • Start-Up Bypass Timer
  • c CSA us (UL Standards), Single Seal, NACE, NEMA 4X
Add-Ons Stainless Steel Tag
In Stock 2 - 5 days
$1,558.73 USD
Does not ship to OH, United States
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1" NPT, 3"U, SST, Lens, CSA view more
  • Process Connection: 1" MNPT
  • Insertion 'U' Length: 3"
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Temperature Ranges
    • Sensor: -55°C to 200°C (-58°F to 392°F)
    • Electronics: -55°C to 65°C (-67°F to 149°F)
  • Local Enclosure: Aluminum Flameproof, 1" FNPT
  • Cover: Flameproof Glass Lens Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials
    • Standard: 316/316L Stainless Steel
  • Outputs/Communications
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable)
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)
  • Electronics - Standard Features
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)
    • Start-Up Bypass Timer
  • c CSA us (UL Standards), Single Seal, NACE, NEMA 4X
Add-Ons Stainless Steel Tag
In Stock 2 - 5 days
$1,594.18 USD
Does not ship to OH, United States
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1" NPT, 4"U, SST, Lens, CSA view more
  • Process Connection: 1" MNPT
  • Insertion 'U' Length: 4"
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Temperature Ranges
    • Sensor: -55°C to 200°C (-58°F to 392°F)
    • Electronics: -55°C to 65°C (-67°F to 149°F)
  • Local Enclosure: Aluminum Flameproof, 1" FNPT
  • Cover: Flameproof Glass Lens Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials
    • Standard: 316/316L Stainless Steel
  • Outputs/Communications
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable)
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)
  • Electronics - Standard Features
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)
    • Start-Up Bypass Timer
  • c CSA us (UL Standards), Single Seal, NACE, NEMA 4X
Add-Ons Stainless Steel Tag
In Stock 2 - 5 days
$1,628.94 USD
Does not ship to OH, United States
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1" NPT, 4"U, SST, Lens, CRN/CSA view more
  • Process Connection: 1" MNPT
  • Insertion 'U' Length: 4"
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Temperature Ranges
    • Sensor: -55°C to 200°C (-58°F to 392°F)
    • Electronics: -55°C to 65°C (-67°F to 149°F)
  • Local Enclosure: Aluminum Flameproof, 1" FNPT
  • Cover: Flameproof Glass Lens Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials
    • Standard: 316/316L Stainless Steel
  • Outputs/Communications
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable)
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)
  • Electronics - Standard Features
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)
    • Start-Up Bypass Timer
  • c CSA us (UL Standards), CRN (Canada-wide), Single Seal, NACE, NEMA 4X
Add-Ons Stainless Steel Tag
In Stock 2 - 5 days
$1,628.94 USD
Does not ship to OH, United States
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 3/4" NPT, 4"U, SST, Lens, CRN view more
  • Process Connection: 3/4" MNPT
  • Insertion 'U' Length: 4"
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Temperature Ranges
    • Sensor: -55°C to 200°C (-58°F to 392°F)
    • Electronics: -55°C to 65°C (-67°F to 149°F)
  • Local Enclosure: Aluminum Flameproof, 1" FNPT
  • Cover: Flameproof Glass Lens Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials
    • Standard: 316/316L Stainless Steel
  • Outputs/Communications
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable)
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)
  • Electronics - Standard Features
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)
    • Start-Up Bypass Timer
  • c CSA us (UL Standards), CRN (Canada-wide), Single Seal, NACE, NEMA 4X
Add-Ons Stainless Steel Tag
In Stock 1 - 5 days
$1,628.94 USD
Does not ship to OH, United States
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 3/4" NPT, 4"U, SST, Lens, CSA view more
  • Process Connection: 3/4" MNPT
  • Insertion 'U' Length: 4"
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Temperature Ranges
    • Sensor: -55°C to 200°C (-58°F to 392°F)
    • Electronics: -55°C to 65°C (-67°F to 149°F)
  • Local Enclosure: Aluminum Flameproof, 1" FNPT
  • Cover: Flameproof Glass Lens Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials
    • Standard: 316/316L Stainless Steel
  • Outputs/Communications
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable)
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)
  • Electronics - Standard Features
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)
    • Start-Up Bypass Timer
  • c CSA us (UL Standards), Single Seal, NACE, NEMA 4X
Add-Ons Stainless Steel Tag
In Stock 2 - 5 days
$1,628.94 USD
Does not ship to OH, United States
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1" NPT, 6"U, SST, Lens, CRN view more
  • Process Connection: 1" MNPT
  • Insertion 'U' Length: 6"
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Temperature Ranges
    • Sensor: -55°C to 200°C (-58°F to 392°F)
    • Electronics: -55°C to 65°C (-67°F to 149°F)
  • Local Enclosure: Aluminum Flameproof, 1" FNPT
  • Cover: Flameproof Glass Lens Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials
    • Standard: 316/316L Stainless Steel
  • Outputs/Communications
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable)
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)
  • Electronics - Standard Features
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)
    • Start-Up Bypass Timer
  • c CSA us (UL Standards), CRN (Canada-wide), Single Seal, NACE, NEMA 4X
Add-Ons Stainless Steel Tag
In Stock 2 - 5 days
$1,699.16 USD
Does not ship to OH, United States
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1" NPT, 9"U, SST, Lens, CRN view more
  • Process Connection: 1" MNPT
  • Insertion 'U' Length: 9"
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Temperature Ranges
    • Sensor: -55°C to 200°C (-58°F to 392°F)
    • Electronics: -55°C to 65°C (-67°F to 149°F)
  • Local Enclosure: Aluminum Flameproof, 1" FNPT
  • Cover: Flameproof Glass Lens Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials
    • Standard: 316/316L Stainless Steel
  • Outputs/Communications
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable)
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)
  • Electronics - Standard Features
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)
    • Start-Up Bypass Timer
  • c CSA us (UL Standards), CRN (Canada-wide), Single Seal, NACE, NEMA 4X
Add-Ons Stainless Steel Tag
In Stock 2 - 5 days
$1,804.14 USD
Does not ship to OH, United States
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 2"U, SST, Blind, CSA view more
  • Process Connection: 1/2" MNPT
  • Insertion 'U' Length: 2"
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Temperature Ranges
    • Sensor: -55°C to 200°C (-58°F to 392°F)
    • Electronics: -55°C to 65°C (-67°F to 149°F)
  • Local Enclosure: Aluminum Flameproof, 1" FNPT
  • Cover: Flameproof Blind Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials
    • Standard: 316/316L Stainless Steel
  • Outputs/Communications
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable)
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)
  • Electronics - Standard Features
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)
    • Temperature Compensation
    • Start-Up Bypass Timer
  • c CSA us (UL Standards), Single Seal, NACE, NEMA 4X
Add-Ons Stainless Steel Tag
In Stock 1 - 5 days
$1,383.53 USD
Does not ship to OH, United States
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1" NPT, 6"U, SST, Blind, CRN/CSA view more
  • Process Connection: 1" MNPT
  • Insertion 'U' Length: 6"
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Temperature Ranges
    • Sensor: -55°C to 200°C (-58°F to 392°F)
    • Electronics: -55°C to 65°C (-67°F to 149°F)
  • Local Enclosure: Aluminum Flameproof, 1" FNPT
  • Cover: Flameproof Blind Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials
    • Standard: 316/316L Stainless Steel
  • Outputs/Communications
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable)
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)
  • Electronics - Standard Features
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)
    • Start-Up Bypass Timer
  • c CSA us (UL Standards), CRN (Canada-wide), Single Seal, NACE, NEMA 4X
Add-Ons Stainless Steel Tag
In Stock 2 - 5 days
$1,523.96 USD
Does not ship to OH, United States
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 6"U, SST, Blind, CRN view more
  • Process Connection: 1/2" MNPT
  • Insertion 'U' Length: 6"
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Temperature Ranges
    • Sensor: -55°C to 200°C (-58°F to 392°F)
    • Electronics: -55°C to 65°C (-67°F to 149°F)
  • Local Enclosure: Aluminum Flameproof, 1" FNPT
  • Cover: Flameproof Blind Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials
    • Standard: 316/316L Stainless Steel
  • Outputs/Communications
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable)
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)
  • Electronics - Standard Features
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)
    • Start-Up Bypass Timer
  • c CSA us (UL Standards), CRN (Canada-wide), Single Seal, NACE, NEMA 4X
Add-Ons Stainless Steel Tag
In Stock 1 - 5 days
$1,523.96 USD
Does not ship to OH, United States
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 1.2"U, SST, Lens, CSA view more
  • Process Connection: 1/2" MNPT
  • Insertion 'U' Length: 1.2"
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Temperature Ranges
    • Sensor: -55°C to 200°C (-58°F to 392°F)
    • Electronics: -55°C to 65°C (-67°F to 149°F)
  • Local Enclosure: Aluminum Flameproof, 1" FNPT
  • Cover: Flameproof Glass Lens Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials
    • Standard: 316/316L Stainless Steel
  • Outputs/Communications
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable)
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)
  • Electronics - Standard Features
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up:
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)
    • Start-Up Bypass Timer
  • c CSA us (UL Standards), Single Seal, NACE, NEMA 4X
Add-Ons Stainless Steel Tag
In Stock 1 - 5 days
$1,558.73 USD
Does not ship to OH, United States
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 3"U, SST, Lens, CRN view more
  • Process Connection: 1/2" MNPT
  • Insertion 'U' Length: 3"
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Temperature Ranges
    • Sensor: -55°C to 200°C (-58°F to 392°F)
    • Electronics: -55°C to 65°C (-67°F to 149°F)
  • Local Enclosure: Aluminum Flameproof, 1" FNPT
  • Cover: Flameproof Glass Lens Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials
    • Standard: 316/316L Stainless Steel
  • Outputs/Communications
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable)
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)
  • Electronics - Standard Features
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)
    • Start-Up Bypass Timer
  • c CSA us (UL Standards), CRN (Canada-wide), Single Seal, NACE, NEMA 4X
Add-Ons Stainless Steel Tag
In Stock 1 - 5 days
$1,594.18 USD
Does not ship to OH, United States
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1" NPT, 6"U, SST, Lens, CSA view more
  • Process Connection: 1" MNPT
  • Insertion 'U' Length: 6"
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Temperature Ranges
    • Sensor: -55°C to 200°C (-58°F to 392°F)
    • Electronics: -55°C to 65°C (-67°F to 149°F)
  • Local Enclosure: Aluminum Flameproof, 1" FNPT
  • Cover: Flameproof Glass Lens Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials
    • Standard: 316/316L Stainless Steel
  • Outputs/Communications
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable)
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)
  • Electronics - Standard Features
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)
    • Start-Up Bypass Timer
  • c CSA us (UL Standards), Single Seal, NACE, NEMA 4X
Add-Ons Stainless Steel Tag
In Stock 2 - 5 days
$1,699.16 USD
Does not ship to OH, United States
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 3/4" NPT, 6"U, SST, Lens, CRN view more
  • Process Connection: 3/4" MNPT
  • Insertion 'U' Length: 6"
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Temperature Ranges
    • Sensor: -55°C to 200°C (-58°F to 392°F)
    • Electronics: -55°C to 65°C (-67°F to 149°F)
  • Local Enclosure: Aluminum Flameproof, 1" FNPT
  • Cover: Flameproof Glass Lens Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials
    • Standard: 316/316L Stainless Steel
  • Outputs/Communications
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable)
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)
  • Electronics - Standard Features
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)
    • Start-Up Bypass Timer
  • c CSA us (UL Standards), CRN (Canada-wide), Single Seal, NACE, NEMA 4X
Add-Ons Stainless Steel Tag
In Stock 1 - 5 days
$1,699.16 USD
Does not ship to OH, United States
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 3/4" NPT, 9"U, SST, Lens, CSA view more
  • Process Connection: 3/4" MNPT
  • Insertion 'U' Length: 9"
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Temperature Ranges
    • Sensor: -55°C to 200°C (-58°F to 392°F)
    • Electronics: -55°C to 65°C (-67°F to 149°F)
  • Local Enclosure: Aluminum Flameproof, 1" FNPT
  • Cover: Flameproof Glass Lens Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials
    • Standard: 316/316L Stainless Steel
  • Outputs/Communications
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable)
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)
  • Electronics - Standard Features
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)
    • Start-Up Bypass Timer
  • c CSA us (UL Standards), Single Seal, NACE, NEMA 4X
Add-Ons Stainless Steel Tag
In Stock 1 - 5 days
$1,804.14 USD
Does not ship to OH, United States
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1-1/2" NPT, 1.2"U, SST, Lens, CRN view more
  • Process Connections: 1-1/2" MNPT
  • Insertion 'U' Length: 1.2"
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Temperature Ranges
    • Sensor: -55°C to 200°C (-58°F to 392°F)
    • Electronics: -55°C to 65°C (-67°F to 149°F)
  • Local Enclosure: Aluminum Flameproof, 1" FNPT
  • Cover: Flameproof Glass Lens Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials:  Standard: 316 Stainless Steel
  • Outputs/Communications
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable)
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)
  • Electronics - Standard Features
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)
    • Start-Up Bypass Timer
  • c CSA us (UL Standards), CRN (Canada-wide), Single Seal, NACE, NEMA 4X
Add-Ons Stainless Steel Tag
In Stock 3 - 14 days
$1,868.11 USD
Does not ship to OH, United States
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1" NPT, 1.2"U, SST, Blind, CSA view more
  • Process Connection: 1" MNPT
  • Insertion 'U' Length: 1.2"
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Temperature Ranges
    • Sensor: -55°C to 200°C (-58°F to 392°F)
    • Electronics: -55°C to 65°C (-67°F to 149°F)
  • Local Enclosure: Aluminum Flameproof, 1" FNPT
  • Cover: Flameproof Blind Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials
    • Standard: 316/316L Stainless Steel
  • Outputs/Communications
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable)
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)
  • Electronics - Standard Features
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)
    • Start-Up Bypass Timer
  • c CSA us (UL Standards), Single Seal, NACE, NEMA 4X
Add-Ons Stainless Steel Tag
In Stock 2 - 5 days
$1,383.53 USD
Does not ship to OH, United States
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 3/4" NPT, 2"U, SST, Blind, CSA view more
  • Process Connection: 3/4" MNPT
  • Insertion 'U' Length: 2"
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Temperature Ranges
    • Sensor: -55°C to 200°C (-58°F to 392°F)
    • Electronics: -55°C to 65°C (-67°F to 149°F)
  • Local Enclosure: Aluminum Flameproof, 1" FNPT
  • Cover: Flameproof Blind Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials
    • Standard: 316/316L Stainless Steel
  • Outputs/Communications
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable)
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)
  • Electronics - Standard Features
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)
    • Start-Up Bypass Timer
  • c CSA us (UL Standards), Single Seal, NACE, NEMA 4X
Add-Ons Stainless Steel Tag
In Stock 1 - 5 days
$1,383.53 USD
Does not ship to OH, United States
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 3/4" NPT, 1.2"U, SST, Blind, CRN/CSA view more
  • Process Connection: 3/4" MNPT
  • Insertion 'U' Length: 1.2"
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Temperature Ranges
    • Sensor: -55°C to 200°C (-58°F to 392°F)
    • Electronics: -55°C to 65°C (-67°F to 149°F)
  • Local Enclosure: Aluminum Flameproof, 1" FNPT
  • Cover: Flameproof Blind Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials
    • Standard: 316/316L Stainless Steel
  • Outputs/Communications
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable)
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software) Downloadable from Kayden.com
  • Electronics - Standard Features
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)
    • Start-Up Bypass Timer
  • c CSA us (UL Standards), CRN (Canada-wide), Single Seal, NACE, NEMA 4X
Add-Ons Stainless Steel Tag
In Stock 1 - 3 days
$1,383.53 USD
Does not ship to OH, United States
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1" NPT, 4"U, SST, Blind, CSA view more
  • Process Connection: 1" MNPT
  • Insertion 'U' Length: 4"
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Temperature Ranges
    • Sensor: -55°C to 200°C (-58°F to 392°F)
    • Electronics: -55°C to 65°C (-67°F to 149°F)
  • Local Enclosure: Aluminum Flameproof, 1" FNPT
  • Cover: Flameproof Blind Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials
    • Standard: 316/316L Stainless Steel
  • Outputs/Communications
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable)
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)
  • Electronics - Standard Features
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)
    • Start-Up Bypass Timer
  • c CSA us (UL Standards), Single Seal, NACE, NEMA 4X
Add-Ons Stainless Steel Tag
In Stock 1 - 5 days
$1,453.74 USD
Does not ship to OH, United States
KAYDEN CLASSIC Thermal Flow, Level, Interface Switch, Modbus, 1/2" NPT, 1.2"U, SST, SST,Lens,CRN/CSA view more
  • Process Connection: 1/2" MNPT
  • Insertion 'U' Length: 1.2"
  • Adjustable Set Point Range: 0-254 feet/s, 0-77 meters/s
  • Input Power: 12-24 VDC & 115-230 VAC, 50-60 Hz
  • Temperature Ranges
    • Sensor: -55°C to 200°C (-58°F to 392°F)
    • Electronics: -55°C to 65°C (-67°F to 149°F)
  • Local Enclosure: Aluminum Flameproof, 1" FNPT
  • Cover: Flameproof Glass Lens Cover
  • Remote Electronics Enclosure and Cover: Not Required
  • Wetted Materials
    • Standard: 316/316L Stainless Steel
  • Outputs/Communications
    • Two Independent Relays (SPDT)
    • 4-20 mA (Thermal Signal, Scalable)
    • Modbus Communication via RS-485
    • RCMS (Remote Control & Monitoring Software)
  • Electronics - Standard Features
    • Automated Redundant Self-Test Diagnostics
    • Display Panel Lock-Out
    • Easy Set-up
      • No Mechanical Jumpers or Trim Pots
      • Intelligent Push Button Interface
      • Constant Display of Operation (Flow/Level)
    • Start-Up Bypass Timer
  • c CSA us (UL Standards), CRN (Canada-wide), Single Seal, NACE, NEMA 4X
Add-Ons Stainless Steel Tag
In Stock 2 - 5 days
$1,558.73 USD
Does not ship to OH, United States

Specifications

Applications

  • Flow
  • Level
  • Interface

Principle of Operation

  • Thermal, Calorimetric

Sensor, Probe Style

  • Insertion Threaded

NPT Connection

  • 1/2” NPT Male
  • 3/4” NPT Male
  • 1” NPT Male
  • 1-1/4” NPT Male
  • 1-1/2” NPT Male
  • 2” NPT Male

Insertion 'U' Length

  • 1.2” (3 cm)
  • 2” (5 cm)
  • 3” (7.5 cm)
  • 4” (10.1 cm)
  • 6” (15.2 cm)
  • 9” (23 cm)
  • 12” (30 cm)
  • 18” (46 cm)
  • Custom Lengths from 6.4 cm to 305 cm (in 1 cm increments)
  • Custom Lengths from 2.5” to 120” (in 1/2” increments)

Wetted Materials

  • 316, 316L Stainless Steel
  • Hastelloy C-276
  • Titanium

Operating Pressure - Sensor

  • CSA - All Process Connections: Max. Working Pressure: 3481 psi (24 MPa)
  • CRN - All Process Connections: Max. Working Pressure: 1990 psi (13.72 MPa), Material: 316/316L Stainless Steel
  • Canadian Registration Number (CRN): 0F22124.2C

Operating Temperature - Sensor

  • -55° to 200° C
  • -67° to 392° F

Sensor Construction

  • All-Welded Construction

Operating Temperature - Electronics

  • -55° to 65° C
  • -67° to 149° F

Switch Point Range

  • Air & Gases: 0.25 to 200 sfps, 0.08 to 60 smps - Standard Condition 21° C (70° F) at 14.7 psi (1 Atm)
  • Hydrocarbon-based Liquids: 0.01 to 5.0 fps, 0.003 to 1.50 mps
  • Water-based Liquids: 0.01 to 3.00 fps, 0.003 to 0.9 mps

Response Time

  • Approximately 0.5 to 30 seconds

Accuracy

  • Flow Service: ± 1.0 % of Set Point Velocity over Operating Range of ± 28° C (± 50° F)
  • Level Service: ± 0.64 cm (0.25”)

Switch Type

  • SPDT Sealed Relay Contacts Rated @ 4 Amps Resistive 230 Vac or 30 Vdc, Max.

Input Power

  • 12-24 Vdc, 120-240 Vac, 50/60 Hz
  • Power Consumption: 6 Watts Max. Fully Configured
  • Universal Power Input

Output

  • 4-20 mA (Thermal Signal, Scaleable) 120 Vac, Max.

Communication

  • Modbus RTU Communication-Alarms, Flow Status & Diagnostics
  • RS-485 Using Kayden's Remote Control & Monitoring Software (RCMS) or other Modbus Compatible Software

Approvals & Certifications

  • Canadian Standards Association Details:
  • CSA Mark with "C" and "US" or with NRTL
  • CSA - Maximum Working Pressure: 24 MPa, 3481 PSI, Single Seal when used with the approved Classic 810 Series sensors.
  • CSA - Input/Supply Rated 12/24 VDC or 120/240 VDC, 50/60 Hz, 6 W Max.
  • CSA - Output/Contacts Rated 120 VAC Max., 30 VDC Max., 4 Amp Max.
  • CSA - Ambient Temperature Rating: -55° C to +65° C (-67° F to +149° F)
  • CSA - Process Temperature Range: -55° C to +200° C (-67° F to +392° F)
  • CSA - Temperature Code: T3
  • CSA - Enclosure Type: 4, IP55
  • CSA - Local Sensor & Electronics Enclosure: Flameproof, Class I, Div. 1, Groups B, C, D, Ex d IIB + H₂ AEx d IIB + H₂ (Class I, Zone 1, Group IIB + H₂) Enclosure Typical 4, IP55 Single Seal Approved Per ANSI/ISA 12.27.01-2003
  • CSA - Remote Electronics Enclosure - Optional Flameproof: Class I, Groups B, C, D, Ex d IIB + H₂ AEx d IIB + H₂ (Class I, Zone 1, Groups IIB + H₂)
  • Canadian Registration Number Details:
  • CRN - All Provinces & Territories of Canada
  • CRN - Material: 316/316L Stainless Steel
  • CRN - Process Connections: 1/2", 3/4", 1", 1-1/4" & 2" Male NPT
  • CRN - Insertion Lengths: 1.2" to 120" (3.0 to 304 cm)
  • CRN - Max. Working Pressure: 1990 psi, 13,720 kPa, 137 bar
  • CRN - Temperature Range: -55° C to +200° C (-67° F to +392° F)
  • CRN - Code of Construction: ASME B31.3
  • CRN - Canadian Registration Number: 0F22124.2C

Electronics - Standard Features

  • 100% Digital Design. Electronics are Environmentally Sealed
  • 4-Adjustable Independent Switch Point Timers
  • Automated Redundant Self-Test Diagnostics
  • Easy Setup: No Mechanical Jumpers or Trim Pots
  • Incrementally Adjustable Heater Power (5 % Steps) with Automatic Over-Range Protection
  • Intelligent User Interface with Push-Button & Constant Display of Operation (Flow/Level)
  • Start-Up Bypass Timer
  • Temperature Compensation
  • Temperature Mode*: Process Temperature may be displayed/graphed in Flow/Level Mode
  • Display Panel Lock-Out*
  • *Configurable only from the Kayden RCM Software

Remote Control & Monitoring Software

  • Adjust Relay Modes
  • Adjust Set Points 1 & 2
  • Load or Save User Settings
  • Lock or Unlock the Electronics Display Panel to Protect the Settings
  • Modify Heater Settings to Optimize Response Time
  • Monitor Operating Status
  • Operated Via a Personal Computer Locally or from a Remote Control Center
  • Visualize the Actions of the Process Via the Graphical Display
  • Many Other Adjustable Features

Environmental Protection

  • IP55
  • IP67
  • NEMA 4X

Local Enclosure Conduit Connection

  • 1” NPT Female Conduit Connection

Local Enclosure & Cover Material

  • Copper-Free Aluminum (Does Not Exceed 0.4 % Copper)

Local Enclosure Cover

  • Glass Lens Cover - Hazardous Areas
  • Blind Cover - Hazardous Areas
  • Buna-N O-Ring on Cover

Local Enclosure & Cover Finish

  • Powder-Coated Polyester TGIC

Remote Electronics Enclosure Cover

  • Glass Lens Cover - Flameproof

Remote Electronics Enclosure & Cover Finish

  • Powder-Coated Polyester TGIC

Storage Temperature

  • Store in a clean & dry environment between -30° & 60° C (-22° & 140° F)

Applications

Media - A few examples 
  • Air and Gases
    • Sour Gas
    • Sweet Gas
  • Liquids
    • Oils
    • Turpentine
    • Water
  • Slurries
    • Pulp

 

Process Media Applications
 
 Flow
  • Ammonia Storage
  • Biogas Flow
  • Catalysis Vessels
  • Chemical Injection & Additive Flow Monitoring
  • Chemical Reactors
  • Chlor-alkali Processes
  • Compressors
  • Condensers
  • Cooling Water
  • Deionization Tanks
  • Digester Gas Flow
  • Distillation Columns
  • Drain Line Flow
  • Emergency Eye Wash & Shower Stations
  • Fermentation Vessels
  • Flare Gas Monitoring
  • Flare Knock-out Drums
  • Flow Monitoring & Verification
  • Heat Exchangers
  • Heat Recovery Steam Generator (HRSG) - Power & Utilities
  • High Pressure Flows
  • Leak Detection
  • Lube Oil Systems
  • Monitoring Purge Air Flow
  • Natural Gas to Boilers
  • Oil Well System Testing
  • Pumps
  • Reboilers
  • Refinery Flow Applications
  • Relief Valve & Rupture Disk Flow Monitoring
  • Remote Indication of Flow via Analog Output & Digital Communications
  • Pump Protection - Dry Alarm
  • Safety Spray Nozzle Monitoring
  • Tank Blanketing
  • Tank Overflow Protection
  • Tanker Loading & Unloading
  • Water & Wastewater
  • Vaporizers
  • Vent Monitoring
 
Level
  • Biogas Dehydration
  • Blending Operations
  • Carbon Slurry Level
  • Compressor Scrubber
  • Compressor Waste Liquid
  • Condensate Receiver Tanks
  • Cooling Tower Basins
  • Crude Desalting
  • Crude Dehydration
  • Deionization Tanks
  • Digester Blow Tanks
  • Free Water Knock-out Tanks - High, Low and Interface Level
  • Geothermal - Degasser Tanks
  • Geothermal - Steam & Brine Separators
  • Leak Detection (Accumulation Reservoir)
  • Lime Slurry Level
  • Mixing & Blending Systems
  • Oil Separators & Treaters - High, Low & Interface Level
  • Production Fluid Storage
  • Pulp Bleaching Towers
  • Pulp Digesters
  • Pulp Storage
  • Pulp Washing Systems
  • Sampler Systems
  • Sand Separators
  • Scrubber Vessels
  • Storage Tanks
  • Sumps - All Types of fluids: Water, Oil, etc.
  • Surge Tanks
  • Tank Overflow
  • Turpentine Recovery
  • Vapor & Liquid Separation
  • Vapor Recovery
 
Interface
  • Crude Desalting
  • Interface Control in Separation Vessels
  • Interface Detection
  • Interface Control & Level Detection in Settling Vessels
  • Liquid-Liquid Extraction - LLX
 
Media
  • Liquids, Air & Gases
  • Slurries
  • Corrosive Liquids
 
Areas
  • Flameproof, Hazardous & General-Purpose Areas
 
IDEAL PROCESS CONDITIONS FOR FLOW
 
Liquids, Air, Gases, Slurries & Emulsion
  • Consistent Process Composition & Temperature
  • Sufficient Straight Run Flow Profile (minimizes turbulence)
  • Recommended Minimum of 5 Pipe Diameters from any Disturbance

 

Air & Gas

  • Clean and Dry
 

UNDESIRABLE PROCESS CONDITIONS FOR FLOW

Liquids, Air, Gases, Slurries & Emulsion
  • Inconsistent Process Composition or Temperature
  • Insufficient Straight Run
  • Aerated Fluids
  • Turbulence
 
Air & Gas
  • Wet or Saturated Air & Gas
 

Solids

  • Dry granulated processes are NOT good candidates for thermal switches

Benefits

The adoption of thermal dispersion flow, level, and interface switches confers tangible operational, economic, and safety advantages. From their high durability and minimal maintenance needs to their seamless integration and adaptability, these instruments support more reliable, efficient, and compliant industrial processes. Thermal dispersion, or calorimetric, flow, level, and interface switches offer a multitude of advantages that contribute to improved process reliability, safety, and cost-effectiveness in industrial settings. These benefits span operational performance, lifecycle economics, and integration flexibility.

HIGH RELIABILITY & LONG-TERM STABILITY
Robust sensor elements and protective housings are highly durable in harsh conditions, allowing them to withstand corrosive fluids, extreme temperatures, high pressures, and abrasive or viscous media.

The fundamental thermal measurement principle is stable over time, ensuring stable, repeatable performance over years of operation.

BROAD APPLICABILITY & VERSATILE SENSING CAPABILITY
A single thermal dispersion instrument can often serve multiple functions—detecting flow/no-flow conditions, monitoring liquid levels, and identifying interface boundaries in multi-layer fluid systems, as it's operating principle and technology are inherently versatile. The same fundamental principle applies to both gases, liquids, and slurries accommodating a wide range of process fluids, including water, oils, chemicals, solvents, and slurries.

Thermal dispersion switches can accurately detect very low flow rates and respond reliably in varying fluid densities, viscosities, and temperatures.

COST-EFFECTIVE OWNERSHIP & LOW MAINTENANCE
With no moving parts to recalibrate, repair, or replace, scheduled maintenance requirements and associated labor costs are drastically reduced, keeping maintenance demands to an extreme minimum.

The inherent ruggedness and simplicity in design lead to an extended service life with intervals between service and fewer unscheduled shutdowns, lowering the total cost of ownership. Kayden thermal dispersion devices require no periodic recalibration and hold their calibration well, further cutting maintenance expenditures.

SAFETY & REGULATORY COMPLIANCE
Kayden's models, standard with fail-safe operation, can be configured to go into safe states under defined fault conditions, supporting plant safety initiatives and regulatory compliance. All models are available with explosion-proof certifications, enabling use in flammable or otherwise hazardous environments while meeting regulatory standards.

EASY INTEGRATION & REDUCED PROCESS IMPACT
Thermal dispersion switches are designed as insertion-type instruments that can be installed through a simple nozzle or port, minimizing piping modifications and associated costs. Because the sensor elements are small and streamlined, their presence in the flow path introduces negligible pressure loss, helping maintain efficiency in fluid transport.

Available in various geometries and installation options, these switches readily fit existing systems and can be located in difficult-to-access or space-restricted areas.

ENHANCED PROCESS CONTROL & OPTIMIZATION
The continuous, real-time monitoring of a steady, non-interrupted data stream enables immediate response to changing conditions, improving process control and product quality. Reliable flow/no-flow and level detection help identify early detection of anomalies and problems such as pump failures, line blockages, leaks, or interface layer shifts before they escalate.

 

THERMAL FLOW, LEVEL & INTERFACE SWITCHES
Kayden's thermal dispersion flow, level, and interface switches and transmitters offer many distinct advantages that make them highly valuable for monitoring and controlling the flow or level of liquids, gases, and slurries in various industrial applications, making them highly effective and dependable for critical applications in industries such as chemical processing, oil and gas, water and wastewater management, and pharmaceuticals, where precise monitoring of flow or level is essential for operational safety and efficiency.


NO MOVING PARTS
Thermal dispersion devices rely on temperature differential rather than mechanical motion, eliminating wear-prone components such as paddles, floats, or turbines. This inherently reduces the likelihood of mechanical failure.


Thermal dispersion switches do not have any moving parts, which significantly reduces the potential for mechanical wear and tear. This absence of moving parts leads to increased durability and reliability, minimizing maintenance requirements and prolonging the lifespan of the device, while providing simpler design and operation, reducing the risk of operational failures, and simplifying maintenance procedures. Choose thermal dispersion switches for their high reliability and simplicity.


VIRTUALLY NO PRESSURE LOSS
The design of thermal dispersion flow sensors ensures that they introduce very little resistance to the flow. This characteristic is crucial in applications where maintaining the existing pressure level is critical.

Thermal dispersion flow sensors, having no moving parts and providing minimal intrusion into the flow, ensure that they do not significantly disrupt the fluid's path or create turbulence, thereby causing minimal interference obstruction to the flow of the medium and reducing the potential for pressure drops. By minimizing pressure loss, these sensors help maintain energy efficiency in the system, reducing the need for additional energy to compensate for pressure drops. This feature makes them ideal for use in systems where pressure stability is crucial, such as in certain chemical processing or HVAC applications.

Kayden's Classic 800 Series of thermal dispersion flow switches and transmitters are particularly advantageous in applications where maintaining the original pressure of the system is crucial. Their design minimizes pressure drop, ensures high accuracy and reliability, and offers a versatile solution for a wide range of industrial applications. These benefits make them an excellent choice when pressure loss is a critical consideration.

EXAMPLE APPLICATIONS

Chemical Processing
Accurate flow measurement without pressure drop helps in precise mixing and reaction control.

Water and Wastewater Treatment
Ensures efficient flow measurement without adding to the system’s pressure load.


HIGH ACCURACY AND SENSITIVITY
Thermal dispersion switches are known for their high accuracy in measuring flow or detecting fluid levels. They can detect low flows and small changes in the flow rate or level, making them suitable for applications requiring precise control and providing consistent and repeatable measurements, which is critical for maintaining the efficiency and quality of industrial processes.
Kayden thermal flow sensors measure the flow based on the cooling effect of the fluid or gas on a heated sensor, providing accurate and direct flow rate measurements without significantly affecting the fluid dynamics.


WIDE RANGE OF MEDIA COMPATIBILITIES
Thermal dispersion switches can be used with a wide range of fluids, including corrosive and dirty media, further broadening their range of suitable applications. They are effective in both liquid and gas applications, which makes them versatile tools for diverse industrial environments. Thermal dispersion switches can be customized with various materials and coatings to handle different types of fluids and operating conditions, enhancing their utility in specialized applications.


EASY INSTALLATION AND INTEGRATION
These switches are fairly compact and easy to install. They can be mounted in various orientations and configurations to suit different system designs. Kayden's thermal dispersion flow sensors are designed for easy insertion into the flow stream, allowing for straightforward installation without major modifications to the system. They can easily be integrated into most process control systems, offering outputs that are compatible with digital control systems, which facilitates easier monitoring and automation.


LOW MAINTENANCE & COST-EFFECTIVE
The minimal maintenance requirements reduce ongoing operational costs. Since they are durable and very reliable, Kayden's thermal dispersion switches and transmitters decrease the need for frequent replacements or extensive and expensive system downtime for repairs. The no-moving parts' construction results in low maintenance requirements and reduced operational downtime. Their robust design means fewer failures, which enhances the safety of the operations, especially in critical processes involving hazardous materials.


OPERATIONAL IN CHALLENGING CONDITIONS
Thermal dispersion technology performs well in extreme environments, including high temperatures and high pressure, as well as in hazardous areas where explosive gases or liquids are present.

Insensitive to Pressure and Temperature Changes
Unlike some other flow or level sensing technologies, thermal dispersion switches are less sensitive to variations in pressure and temperature, which can affect the accuracy and reliability of flow measurements in other sensor types.


NO CALIBRATION REQUIRED
Once installed and configured, thermal dispersion switches generally do not require recalibration. They maintain their accuracy over time, offering stable and precise readings, which is essential for maintaining process control without introducing pressure variability.

Applications Overview

KAYDEN CLASSIC FLOW SWITCHES

Alarm Activation
If the flow rate drops below a predetermined threshold, indicating potential issues such as a blockage, pump failure, or a leak, the thermal dispersion flow switch detects this change.


Chemical Injection Monitoring
Ensuring precise flow rates of chemicals injected into processes to maintain desired chemical reactions and product quality.
 
Chemical Processing
Monitoring flow rates of chemicals in pipelines to ensure proper mixing and reactions.


Cooling Water Flow Monitoring
Monitoring the flow of cooling water to prevent overheating of machinery.


Flow Detection and Monitoring
The thermal dispersion flow switch is installed in the cooling water pipeline. It constantly monitors the flow rate of the cooling water.


Food and Beverage
Ensuring proper flow in processes like pasteurization and cleaning in place (CIP).


HVAC Systems
Ensuring adequate airflow in heating, ventilation, and air conditioning systems.


Oil and Gas
Monitoring flow in pipelines to detect leaks or blockages and ensure safe operations.


Pharmaceutical Manufacturing
Ensuring precise flow rates of liquids and gases in production processes.


Power Generation
Monitoring cooling water flow in turbines and generators to prevent overheating.


Pulp and Paper
Monitoring flow rates of slurries and chemicals in various stages of production.


Pump Protection
The Kayden CLASSIC 800 Series of thermal switches can detect the presence or absence of flow in a pipeline. When the flow falls below a predetermined threshold, indicating conditions like dry running or reduced flow that could damage the pump, the switch can trigger an alarm or shut down the pump to prevent damage. Ensuring the continuous and adequate flow through the pump is important for maintaining the safe and efficient operation of the pumps and associated machinery.


Semiconductor Manufacturing
Ensuring proper flow of cooling and process fluids to maintain equipment performance.


Solvent Flow Monitoring
Ensuring the proper flow of solvents in extraction and purification processes


Stock Preparation
Ensuring consistent flow rates of slurries to maintain quality and process efficiency.


Wastewater Treatment
Monitoring flow rates in effluent treatment processes to ensure compliance with environmental regulations.


Water Treatment
Monitoring flow rates in filtration systems to maintain efficiency and compliance. 


 
KAYDEN CLASSIC LEVEL SWITCHES
 
Kayden CLASSIC 800 Series thermal dispersion level switches are highly versatile and can be used in various applications across multiple industries.

Chemical Processing
Monitoring liquid levels in chemical reactors and storage tanks to ensure safe and efficient operations.

Food and Beverage
Maintaining levels in mixing and fermentation tanks to ensure product quality.


HVAC Systems
Monitoring levels in condensate tanks and boilers to prevent system malfunctions.

Marine Applications
Monitoring bilge and ballast water levels to ensure vessel stability and safety.

Oil and Gas
Monitoring levels in separators and storage tanks to ensure safe handling and processing.

Pharmaceuticals
Maintaining precise liquid levels in reaction vessels and storage tanks to ensure product consistency and safety.


Pulp and Paper
Maintaining levels in slurry tanks and chemical feed tanks to ensure process efficiency.

Sump and Drain Monitoring
Ensuring proper levels in sumps and drains to prevent flooding or pump damage.


Tank Level Monitoring
Detecting the level of liquids in storage tanks to prevent overflows or dry running.
 
Water Treatment
Ensuring proper levels in clarifiers and reservoirs for efficient water treatment processes.

 

BENEFITS

Reliability
Thermal dispersion flow switches are highly reliable and accurate, ensuring consistent protection for the pumps.


Maintenance
They require minimal maintenance, making them a cost-effective solution for long-term pump protection.


Versatility
Suitable for various types of fluids, including water, chemicals, and slurries.

Pump Protection

Thermal Dispersion Flow Switches for Pump Protection

In a wide range of industrial environments—from petrochemical processing and wastewater treatment to power generation and food & beverage production—pumps serve as vital components for fluid transfer and circulation. Ensuring their dependable and efficient performance is essential for maintaining throughput, product quality, and operational safety. However, conditions such as dry running, obstructed suction or discharge lines, and cavitation can cause substantial equipment damage, inflated maintenance costs, and compromised process integrity.

Thermal dispersion flow switches have proven to be effective tools for identifying these problematic scenarios early. By providing timely interlocks, they help prevent costly breakdowns. This paper offers a detailed exploration of how thermal dispersion flow switches operate, their advantages, considerations for choosing and installing them, and methods for integrating them into holistic pump protection protocols.

Thermal dispersion flow switches deliver a dependable, low-upkeep, and highly sensitive approach to preventing pump damage caused by low-flow or no-flow conditions. By harnessing the heat transfer principle, these devices are well-suited to harsh industrial settings and excel at detecting subtle flow changes. With the proper selection, careful installation, and integration into broader pump protection strategies, thermal dispersion flow switches significantly boost equipment reliability, lower maintenance expenses, and help maintain stable, safe, and productive fluid-handling operations.

1. Introduction
Safeguarding pumps is a critical factor in fluid handling within industrial applications. Pumps frequently operate under challenging conditions involving high pressures, corrosive or abrasive media, fluctuating temperatures, and varying flow profiles. These stressors can affect components such as seals and bearings. When a pump runs under no-flow or low-flow circumstances, or if a pipeline obstruction or closed valve impedes flow, the pump can overheat, cavitate, and ultimately fail.

While traditional mechanical flow sensors (like paddle switches or turbine meters) can detect flow interruptions, their moving parts introduce complexity, heighten maintenance demands, and reduce long-term reliability. In contrast, thermal dispersion technology leverages heat transfer rather than mechanical movement. These switches can reliably sense minimal flow rates, respond rapidly to changing conditions, and withstand harsh environments—making them well-suited for integrated pump protection strategies.

2. How Thermal Dispersion Flow Switches Work
A typical thermal dispersion switch incorporates two temperature sensors housed within a single probe that is inserted into the fluid. One sensor is slightly heated using a controlled current, while the other measures the ambient fluid temperature. The rate at which flowing fluid dissipates heat from the warmed sensor is proportional to the fluid’s mass flow or velocity.

When flow is restricted or absent, insufficient fluid passes by to cool the heated sensor, causing the temperature difference between the sensors to remain pronounced. Conversely, when fluid moves normally, the enhanced cooling effect reduces this temperature differential. By continuously tracking these changes, the switch can accurately determine when flow is present, critically low, or completely halted.

Key Advantages of Thermal Dispersion

No Moving Parts
Minimizes mechanical failures and maintenance needs.

High Sensitivity at Low Flow
Detects slight variations in flow rates, offering early indicators of dry-running conditions.

Rugged Construction
Withstands corrosive, abrasive, high-temperature, and high-pressure media.

Minimal Pressure Loss
The small sensor profile generates negligible flow resistance, preserving operational efficiency.


3. Pump Protection Scenarios and the Role of Flow Switches

3.1 Dry-Run Prevention
One of the most common pump failure modes occurs when the suction line is deprived of liquid—perhaps due to a closed valve, blocked inlet, vapor lock, or depleted feed tank. Running a pump without adequate fluid leads to overheating and damage to seals and bearings. By installing a thermal dispersion flow switch in the suction line, operators can detect a drop or absence of flow and deactivate the pump before it sustains heat-related harm.

3.2 Discharge Line Obstruction
If the discharge line becomes blocked or a downstream valve remains closed, pressure builds and flow decreases to negligible levels. Without adequate movement, the pump faces elevated temperatures and mechanical stress. A thermal dispersion switch placed downstream of the pump can identify reduced or zero-flow scenarios, prompting remedial actions such as opening a bypass line, adjusting valves, or shutting the pump down.

3.3 Low-Flow Conditions and Cavitation
Though thermal dispersion switches do not measure cavitation directly, early detection of reduced flow—especially under non-typical conditions—can help avert cavitation. By alerting operators to abnormal low-flow states, these switches enable timely intervention, whether it involves adjusting fluid parameters, altering valve positions, or activating safety interlocks.

4. Considerations for Selecting Thermal Dispersion Flow Switches in Pump Protection

4.1 Fluid Compatibility
The sensor’s wetted materials must endure the fluid’s corrosivity, particulate content, and temperature extremes. Common choices include stainless steel, titanium, and hastelloy C-276. Appropriate material selection ensures durability and reduces contamination risks.

4.2 Operating Conditions
The chosen switch must tolerate the system’s temperature and pressure envelopes. Verify that its maximum rated temperature and pressure aren’t exceeded. Thermal dispersion switches commonly support broad temperature ranges (from cryogenic conditions up to several hundred degrees Celsius) and high pressures (frequently above 100 bar, depending on the model).

4.3 Flow Sensitivity & Setpoints
Different processes and fluids demand distinct low-flow thresholds. The switch should allow for adjustable or pre-defined setpoints to differentiate normal variations from truly hazardous states. Carefully calibrating the alarm point ensures effective pump protection without frequent nuisance alarms.

4.4 Response Time
Match the switch’s reaction speed to your pump’s dynamics. In rapidly changing scenarios—like sudden valve closures or pump startup phases—faster response times are crucial. Many thermal dispersion switches offer adjustable time delays to prevent false trips from brief flow interruptions.

4.5 Sensor Placement and Mounting
Proper insertion length and orientation are essential for accurate flow detection. The sensor must be fully immersed in the fluid and located in a stable, representative flow region. Avoid placing it immediately after bends, valves, or fittings that create turbulence. Adhere to the manufacturer’s guidelines for recommended straight run lengths.

5. Installation and Commissioning Guidelines

5.1 Choosing the Right Spot
Position the flow switch in a section of pipe with stable, uniform flow. This may be downstream of the pump or upstream on the suction line, depending on the application (detecting no-flow at suction or discharge). Typically, maintain at least 10 diameters of straight pipe upstream and 5 downstream, though this can vary based on specific conditions and manufacturer recommendations.

5.2 Wiring and Integration
Thermal dispersion switches typically offer relay outputs or 4-20 mA signals. Integrate these into the pump’s control systems, interlocks, or a Distributed Control System (DCS). When a no-flow or low-flow threshold is reached, the switch can trigger pump shutdown, alarms, or valve adjustments. Ensure proper grounding, shielding, and compliance with any hazardous area requirements.

5.3 Calibration and Setpoint Validation
Follow the manufacturer’s instructions to set the trip threshold. Calibration often involves operating the pump under normal conditions and adjusting the switch so it triggers at the desired flow level. Some devices allow setpoint adjustments via onboard controls, software interfaces, or external instrumentation.

5.4 Regular Functional Checks
Although thermal dispersion switches are low-maintenance, periodic testing is advised for critical applications. Verify that alarms and shutdown sequences occur at the correct flow thresholds. If process conditions evolve—such as changes in fluid viscosity or temperature—recalibration may be necessary.

6. Integrating Flow Switches into a Comprehensive Pump Protection Plan

6.1 Redundancy and Layering
For especially critical pumps, consider adding redundant sensors. You can place multiple sensors in different locations or pipelines for increased reliability. Combine them with pressure, vibration, and temperature sensors, as well as motor current monitors, to form a robust pump health monitoring ecosystem.

6.2 Diagnostic and Data Capabilities
Modern thermal dispersion switches equipped with digital communication (e.g., MODBUS®) can deliver diagnostic data such as sensor health and drift detection. Feeding this information into a plant asset management system supports predictive maintenance and reduces unplanned downtime.

6.3 Compliance and Safety Standards
In hazardous environments, ensure that the chosen flow switch meets relevant safety and regulatory standards (e.g., CSA, UL, or CRN certifications). Models with intrinsically safe or explosion-proof designs are widely available.

7. Case Study

Scenario
A large chemical plant experienced repeated pump failures due to intermittent dry running during batch startups. Filters in the pump’s suction line occasionally became clogged, restricting flow.

Solution
Thermal dispersion flow switches were installed on each pump’s suction line and calibrated to trip slightly above the pump’s minimum flow requirement.

Results
Lower Maintenance Costs
Early pump shutdowns prevented damage from overheating and seal degradation.

Improved Operational Efficiency
Operators quickly identified and cleared clogged filters, reducing startup issues.

Enhanced Equipment Life
By preventing frequent dry runs, the pumps’ mean time between failures (MTBF) improved, lowering long-term costs.

 

References

ISA (International Society of Automation). “Pump Protection and Reliability Standards,” ISA Publications, 2020.
API (American Petroleum Institute) Standard 610, “Centrifugal Pumps for Petroleum, Petrochemical and Natural Gas Industries.”
Galvan, J., “Flow Switch Technology Review and Selection Guidelines,” Instrumentation & Control Magazine, Vol. 46, No. 3, 2021.
Cruz, P. and L. Martin, “Integrating Flow Measurement Devices in Pump Protection Schemes,” Chemical Engineering Progress, Vol. 117, No. 2, 2022.


Acknowledgements
The development of advanced thermal dispersion technology and its ongoing improvement are indebted to the research efforts of instrument manufacturers, industrial consortia, and standardization bodies dedicated to improving safety, efficiency, and reliability in industrial process operations.

Leak Detection

Thermal Dispersion Flow Switches in Leak Detection Applications

Industrial processes and fluid transportation networks—ranging from pipelines carrying hydrocarbons to chemical supply lines feeding manufacturing processes—are vulnerable to leaks. Even minor leaks can cause serious safety risks, product loss, environmental damage, and regulatory non-compliance. Early and accurate detection of leaks is, therefore, a cornerstone of responsible and profitable operations. Among various leak detection technologies, thermal dispersion flow switches offer a uniquely effective solution for identifying subtle flow changes that may indicate a leak condition.

Thermal switches provide robust, low-maintenance performance even under challenging conditions. This paper details the principles of thermal dispersion flow technology, describes its strengths in leak detection scenarios, outlines factors for selection, installation, and integration, and provides a framework for using these switches as part of a comprehensive leak detection and mitigation strategy.

 

1. Introduction
Leak detection is critical across numerous industries:

Oil & Gas Pipelines
Preventing spills and reducing product losses ensures environmental protection and compliance with stringent regulations.


Chemical Processing Plants
Detecting leaks of hazardous chemicals protects worker safety, reduces clean-up costs, and prevents off-spec product.


Water and Wastewater Systems
Identifying minor leaks conserves resources, prevents contamination, and reduces infrastructure strain.


Food & Beverage and Pharmaceutical Lines
Ensuring product integrity and meeting quality standards by promptly identifying any fluid loss.


While leak detection has traditionally relied on volumetric balances, mass flow measurement, or pressure drop indicators, these methods often struggle to detect small, slow-onset leaks. Mechanical flow switches might fail due to fouling or wear in harsh environments. In contrast, thermal dispersion flow switches excel at detecting subtle deviations in flow conditions without relying on moving parts, thus offering improved reliability, lower maintenance, and heightened sensitivity to small flow disturbances.

 

2. Principles of Thermal Dispersion Technology

Thermal dispersion devices commonly use two sensors embedded in one insertion probe:

Heated Sensor
A small current is applied to this sensor, causing it to warm above the fluid’s ambient temperature.


Reference (Unheated) Sensor
This sensor measures the fluid’s temperature directly.


When the fluid flows around the probe, it removes heat from the heated sensor. The rate of heat removal correlates to the mass flow or velocity of the fluid. Under stable, leak-free conditions, the switch is calibrated to a known temperature differential representing normal flow. If a leak occurs downstream, the flow profile can change subtly. These changes manifest as variations in the temperature differential, which the switch can detect and use to trigger alarms or shutdowns.

Key Attributes Beneficial for Leak Detection

  • High Sensitivity to Small Flow Changes
    Even slight flow reductions due to small leaks can be detected.

  • No Moving Parts
    Minimizes maintenance and instrument drift, ensuring long-term stability and repeatability.

  • Versatile Media Compatibility
    Suitable for liquids, gases, and slurries, allowing application across diverse industries.

  • Robust Construction
    Resistant to corrosion, high pressures, and broad temperature ranges found in industrial lines.


3. Leak Detection Challenges and How Thermal Dispersion Addresses Them

3.1 Early and Subtle Leak Detection
Traditional monitoring techniques often rely on large flow variances or pressure drops to confirm a leak. By contrast, thermal dispersion flow switches can be set to detect small deviations in expected flow patterns. For example, if a petroleum pipeline experiences a small pinhole leak downstream, the overall flow at a measurement point may subtly fluctuate. The thermal dispersion switch, pre-calibrated to recognize normal flow conditions, will pick up on this subtle differential and trigger an alert.

3.2 Dirty, Corrosive, or Variable Fluid Conditions
Pipelines and process lines may carry viscous slurries, corrosive acids, dirty wastewater, or multiphase mixtures. Thermal dispersion probes are available in materials such as stainless steel, Hastelloy®, and other high-grade alloys to withstand harsh media. As they have no moving parts, there is no risk of mechanical jamming or sticking due to fouling. Thermal dispersion sensors also adapt well to fluid characteristic changes—density, viscosity, or temperature—as their calibration can account for these factors.

3.3 Minimal Pressure Drop and Unobtrusive Monitoring
Unlike inline flow meters or complex instrumentation, a thermal dispersion sensor’s small insertion probe offers minimal disturbance to the flow. This feature ensures that system efficiency is not compromised. The negligible pressure drop is crucial in large pipelines where maintaining flow efficiency is economically essential.

 

4. Selection Criteria for Thermal Dispersion Flow Switches in Leak Detection

4.1 Fluid Compatibility and Wetted Materials
Select materials that can withstand long-term exposure to the process fluid. Consider corrosion resistance, temperature rating, and any coatings that might enhance sensor longevity. Proper materials ensure minimal sensor drift and reduced maintenance intervals.

4.2 Measurement Range and Sensitivity
Determine the baseline or normal operational flow range. The chosen thermal dispersion switch should be capable of detecting slight deviations in this range. Because leak detection often hinges on very small changes, ensure the device provides fine resolution and adjustable setpoints.

4.3 Response Time and Stability
Leaks can develop slowly or occur suddenly. A thermal dispersion flow switch should have a response time suitable for the system’s dynamic characteristics. Many devices offer adjustable response delays to avoid nuisance alarms caused by transient disturbances (e.g., pump starts, valve adjustments).

4.4 Environmental and Safety Certifications
Check for necessary certifications, especially if the fluid is flammable, toxic, or explosive. Many thermal dispersion switches carry intrinsic safety or explosion-proof ratings (e.g., ATEX, IECEx, FM/CSA) to ensure compliance with industry regulations and safe operation in hazardous areas.

 

5. Installation and Commissioning Practices

5.1 Optimal Sensor Placement
Proper placement is crucial for effective leak detection. Consider the following guidelines:

  • Upstream and Downstream Monitoring
    Placing switches at strategic pipeline intervals allows comparison of flow conditions at different points. A discrepancy between adjacent measurements can indicate a leak in the intervening segment.

Avoid Turbulence and Disturbances
Adhere to the manufacturer’s guidelines on straight-run pipe lengths. Typically, 10 diameters of straight pipe upstream and 5 downstream help ensure stable flow conditions and reliable readings.


5.2 Calibration to Baseline Conditions
Before commissioning, establish a baseline. Operate the system under known, leak-free conditions and record the stable temperature differential. Set alarm thresholds based on statistically significant deviations from this baseline, factoring in normal operational variances.

5.3 Integration with Control Systems
Thermal dispersion flow switches provide relay contacts, 4-20 mA signals, or digital communication outputs (e.g., HART®, Modbus®). Integrate these signals with a plant’s Distributed Control System (DCS) or Supervisory Control and Data Acquisition (SCADA) system.

In case of a suspected leak, the control system can:

  • Trigger alarms or visual indicators.
  • Initiate pump shutdown or valve adjustments to isolate the affected section.
  • Notify operations and maintenance personnel for immediate inspection.

5.4 Periodic Verification and Maintenance
While thermal dispersion devices are low maintenance, periodic functional tests are recommended:

  • Flow Simulations
    Temporarily modulate flow conditions to confirm that the switch triggers at the intended thresholds.
  • Inspection for Fouling or Deposits
    Although rare, if the process fluid is heavily fouling, occasional cleaning may be beneficial to ensure optimal heat transfer characteristics.


6. Integration into a Comprehensive Leak Detection Strategy

6.1 Complementary Technologies
Thermal dispersion switches can be one element of a multi-layered leak detection solution. Integrating them with other techniques can enhance reliability and reduce false alarms:

  • Pressure and Temperature Sensors
    Compare flow indications with pressure and temperature profiles to confirm or refute suspicions of leaks.
  • Flow Meters and Mass Balances
    Use thermal dispersion switches as an early warning, supported by more complex flow meters for detailed quantification of leak rates.
  • Acoustic Emission Detection
    Combine thermal dispersion detection with acoustic sensors that listen for the distinctive sound signatures of leaks.


    6.2 Alarming and Response Protocols
    Having a well-defined escalation procedure following a thermal dispersion alarm is critical.

Ensure that upon detection:

  • Operators receive immediate notification.
  • Automatic or semi-automatic isolation protocols can run, shutting valves or pumps to limit product loss.
  • Incident reporting and root-cause analysis follow to prevent recurrence.


6.3 Regulatory Compliance and Environmental Stewardship
Leaking hazardous fluids poses environmental and safety risks. By detecting leaks early, thermal dispersion switches help operators meet stringent regulatory requirements (e.g., EPA, OSHA, local environmental laws) and uphold corporate social responsibility commitments. Early leak detection also aids in maintaining public trust and mitigating financial and reputational damage.

7. Case Study Example

Background
A petrochemical facility used a network of pipelines to distribute intermediate products between process units. Despite employing volumetric flow metering and pressure sensors, the facility occasionally failed to detect small leaks in a timely manner, resulting in product loss and concerns over soil contamination.

Solution
Thermal dispersion flow switches were installed at strategic intervals along the critical pipelines. Each switch was calibrated to a “normal” flow differential baseline. Any deviation beyond a small tolerance triggered an alarm in the control room.

Results
Early Leak Detection
The facility identified small leaks before they grew significant, reducing product loss and clean-up costs.


Enhanced Environmental Safety
Prompt isolation of leaking segments minimized the risk of environmental damage and regulatory penalties.


Operational Efficiency
Operators leveraged the early-warning capability of the thermal dispersion switches to schedule targeted maintenance, reducing unplanned downtime.


8. Conclusion
Thermal dispersion flow switches are a powerful tool in the arsenal of leak detection technologies. Their ability to detect subtle flow changes in challenging environments, combined with robust construction and low maintenance requirements, makes them invaluable for protecting personnel, preserving the environment, and ensuring operational excellence. By carefully selecting, installing, calibrating, and integrating these instruments into a broader leak detection strategy, organizations can significantly improve their capacity for early warning and swift response, ultimately reducing losses and maintaining regulatory and ethical standards in fluid handling operations.

 

References

API (American Petroleum Institute) RP 1130, “Computational Pipeline Monitoring for Liquid Pipelines.”
ISA (International Society of Automation). “Effective Leak Detection Systems and Best Practices,” ISA Publications, 2020.
ANSI/AWWA M36, “Water Audits and Loss Control Programs.”
Rathwell, G. and Liu, H., “Real-Time Leak Detection in Pipelines: Advances in Sensor Technology,” Journal of Pipeline Engineering, Vol. 15, 2022.
Cruz, P., “Integrating Non-Intrusive Flow Measurement Devices for Early Leak Warning,” Chemical Engineering Progress, Vol. 117, No. 5, 2022.


Acknowledgements
The ongoing development and refinement of thermal dispersion technology, as well as best practices in leak detection strategies, are the result of collaborative efforts by equipment manufacturers, standards organizations, and industry professionals dedicated to preserving safety, efficiency, and environmental integrity in fluid transport systems.

Operating Principle

Kayden's CLASSIC 800 Series thermal flow, level, and interface switches and transmitters detect and monitor the flow rate or level/interface of a liquid or gas in a system based on the principle of thermal dispersion or thermal differential.
 
The CLASSIC 800 Series operates by measuring the amount of heat carried away by the process media as it moves past a heated temperature sensor, compared to a reference sensor that measures the ambient temperature of the process media. The difference in temperature between these two sensors is used to determine the flow rate, interface, or point-level condition.
Kayden calorimetric flow and level switches, also referred to as thermal flow monitors or level monitors, function as follows:
 
Heating Element
The thermal switch has a heating element (or sensor) that is warmed to a certain temperature above the process media's temperature.
 
Temperature Sensors 
Alongside the heating element, the device includes temperature sensors. One sensor measures the temperature of the heated element, while another measures the ambient temperature of the process media.
 
Flow Detection 
When there is no flow or the flow is below a certain threshold, the temperature differential between the heated sensor and the ambient process media is more significant. As the flow rate increases, the process media carries away more heat from the heated sensor, reducing the temperature difference between the heated element and the reference element.
 
Level Detection 
When the level of the process media rises and comes into contact with the heated probe, the probe cools down due to the increased heat dissipation caused by the cooler process media. Conversely, when the level drops and the probe is exposed to air, the probe's temperature rises because air's thermal conductivity is lower, and it dissipates less heat.
 
Signal Output 
The switch translates the temperature difference into an electrical signal that can trigger an alarm, activate a relay, or send a signal to a control system, indicating whether the flow rate is above or below a preset threshold.
 
Thermal flow and level switches are known for their simplicity, reliability, and the ability to work without moving parts, which minimizes maintenance and the risk of mechanical failure.

Kayden's thermal switches are highly versatile and can be used in various applications, including cooling circuits, pump protection (to ensure there is flow in a system and prevent dry running), and process control in industries such as chemical manufacturing, pharmaceuticals, and food and beverage production.
 
Thermal level switches can be used for level detection in a wide range of applications, including overfill protection and ensuring proper filling or emptying of tanks and containers. These monitors are suitable for use with various materials, including liquids and slurries, and can operate in challenging conditions, such as high pressure and temperature environments.
 
Kayden's thermal dispersion flow, level, and interface sensing technology provides accurate results to achieve highly reliable and repeatable setpoint detection in a wide range of demanding applications, all while providing a long service life.

Documentation

Outline Drawings