Description
Features
- Vacuum ranges through 0 psig to 15,000 psig; absolute ranges from 0 psia to 15 psia through 0 psia to 300 psia
- Standard 4 mA to 20 mA output
- 316 and 17-4PH Stainless Steel wetted parts
- CE compliant to suppress RFI, EMI and ESD
- Ideal for applications including aerospace equipment, computer interface & data logging, laboratory & test equipment and precision measurement
Configure
Specifications
Specifications
Brand
Output Signal
- 0-10 Vdc, 3-Wire
- 0-5 Vdc, 3-Wire
- 4-20 mA, 2-Wire
Pressure Range
- bar: 0 to 1,034
- Inches Hg: -30 to 0
- kPa: 0 to 103,421
- psig: 0 to 15,000
Accuracy
- ± 0.025 % of Full Scale BFSL
- ± 0.05 % of Full Scale BFSL
Environmental Protection
- IP65
Electrical Protection
- Overvoltage
- Reverse Polarity
- Short Circuit
Approvals & Certifications
- CE Compliant to Suppress RFI, EMI & ESD
Pressure Type
- Absolute
- Gauge
- Vacuum
NPT Connection
- 1/2” NPT Male
- 1/4” NPT Male
Ambient Temperature
- 0° to 70° C (32° to 160° F)
Storage Temperature
- -20° to 70° C (-5° to 160° F)
Process Temperature
- -20° to 70° C (-5° to 160° F)
Connection Material
- 316 Stainless Steel
Wetted Materials
- 316 Stainless Steel for Vacuum Through 300 psi
- 17-4PH Stainless Steel for ≥ 500 psi
Enclosure, Body Material
- 316 Stainless Steel
Shock
- 100 g as Per IEC 60068-2-27
Vibration
- 15 g as Per IEC 60068-2-6
Electromagnetic Rating
- CE Compliant to EMC Norm EN 61326:2014/A1:1998
- RFI, EMI and ESD Protection
Power Requirement
- 14-30 Vdc (0-10 Vdc, 3-Wire)
- 9-30 Vdc (4-20 mA, 2-Wire, 0-5 Vdc, 3-Wire)
Electrical Connectors
- 54" Integral Cable
- M12 x 1, 4-Pin
Options
- Threaded Orifice
Load Limit
- ≤ (VPower-10) / 0.020 Amp for 4-20 mA
- ≥ 10,000 ohms for 0-10 Vdc, 3-Wire
- ≥ 5,000 ohms for 0-5 Vdc, 3-Wire
Compensated Temperature
- 0° to 70° C (32° to 160° F)
Proof Pressure
- 1.5 times Full Scale for 0 to 15,000 psi
- 2 times Full Scale for Ranges psi: 0 to 300 through psi: 0 to 10,000
- 3 times Full Scale for Ranges psi: 0 to 5 through psi: 0 to 200
Burst Pressure
- 3 times Full Scale for psi: 0 to 15,000
- 4 times Full Scale for Ranges psi: 0 to 300 through 0 to 10,000
- 4 times Full Scale for Ranges psi: 0 to 5 through psi: 0 to 200
Stability
- ≤ ± 0.1 % of Full Scale
- 5 psi ± 0.2 % of Full Scale Per Year
Response Time
- < 300 milliseconds (Between 10 % to 90 % of Full Scale)