Images are representations only.

Vegaswing 51 Vibrating Level Switch

Brand: VEGA
The VEGASWING 51 is used as a universal level switch in liquids with small dimensions. 

Independent of the mounting position, it detects reliably with millimetre accuracy the limit level. 

The instrument can be used as empty or full detector, as approved overfill protection, dry run protection or pump protection in vessels and pipelines. 

The VEGASWING 51 is an economical solution with maximum reliability and safety.
Features
  • Minimum time and cost expenditure due to simple setup without medium
  • Precise and reliable function due to product-independent switching point
  • Low Maintenance Costs
The VEGASWING 51 is used as a universal level switch in liquids with small dimensions. 

Independent of the mounting position, it detects reliably with millimetre accuracy the limit level. 

The instrument can be used as empty or full detector, as approved overfill protection, dry run protection or pump protection in vessels and pipelines. 

The VEGASWING 51 is an economical solution with maximum reliability and safety.
Features
  • Minimum time and cost expenditure due to simple setup without medium
  • Precise and reliable function due to product-independent switching point
  • Low Maintenance Costs

Specifications

Brand

Ambient Temperature Range

  • -40° to 70° C (-40° to 158° F)

Applications

  • Liquids

Approvals & Certifications

  • ABS
  • GL
  • LRS

BSP Connection

  • G 1/2”

Enclosure, Body Material

  • 316L Stainless Steel
  • Plastic PEI (Polyetherimide)

Environmental Protection

  • IP67

Flange Size - 1-1/2” (DN 40)

  • 1-1/2” (DN 40) - PN 40

Flange Size - 1” (DN 25)

  • 1” (DN 25) - PN 40

Flange Size - 2” (DN 50)

  • 2” (DN 50) - PN 25

Hysteresis

  • 0.08” (2 mm) Approximately with Vertical Installation

NPT Connection

  • 1/2” NPT

Operating Voltages

  • 20-253 Vac
  • 20-253 Vdc
  • 50/60 Hz

Output

  • 10-250 mA

Output Format

  • Contactless Electronic Switch
  • Transistor (NPN/PNP)

Power Requirement

  • 3 mA Approximately (Via Load Circuit)

Pressure Range

  • psi: -14.5 to 928 (kPa: -100 to 6,400, bar: -1 to 64)

Process Fitting Details

  • Hygienic Fittings

Process Temperature

  • -40° to 150° C (-40° to 302° F)

Response Time

  • 500 milliseconds - Switching Delay (ON/OFF)

Seat / Seal Material

  • Klingersil C 4400

Size

  • Clamp: 1”
  • Clamp: 1-1/2”
  • Clamp: 2”

Storage Temperature

  • -40° to 80° C (-40° to 176° F)

Wetted Materials

  • 316L Stainless Steel