Description
Universal non-rotating torque meters combining accuracy, sturdiness and easiness to install.
Features- Easy to install, compact design
- Protection IP 54, IP 67
- Materials:
- Stainless steel (6200)
- Nickel plated steel (6205)
- Cable length: 3m
- Available options (non exhaustive list):
- ATEX intrinsic safety Ex II 1GD Ex ia IIC T6 or T4 Ga Ex ia IIIC T80° C Da
- High service temperature (up to 180° C)
- Amplified (0-10 V, 4 to 20 mA) and digital output signal (RS-232C, RS-485, USB)
- Double strain-gauge bridge
- Also available as standard reference torque meters
Configure
Specifications
Specifications
Applications
- Equipment Calibration
- Laboratories
- Torque Control
- Torque Measurement
Approvals & Certifications
- ATEX Intrinsic Safety Ex II 1 GD Ex ia IIC T6 or T4 Ga Ex ia IIIC T80° C Da
- CE
Cable Length
- 10 feet (3 metres)
Capacity
- 10 to 2,000 Nm
Communication
- RS-232C
- RS-485
- USB
Electrical Connectors
- DIN 45322
Enclosure, Body Material
- Nickel-Plated Steel (6205)
- Stainless Steel (6200)
Environmental Protection
- IP54
- IP67
Excitation Voltage
- 10 Vdc
- 3-12 Vdc - Nominal Range
Insulation Resistance
- > 5,000 megaohms at 50 V
Linearity
- < ± 0.25 % of Full Scale - Error
Load
- > 300 % of Full Scale - Breaking
- 50 % of Full Scale - Dynamic Loading
Load Limit
- 130 % of Full Scale
Operating Temperature
- 180° C (356° F) - High Service Temperature
Repeatability
- < ± 0.1 % of Full Scale - Error
Resistance
- 352 ± 2 ohms - Input/Output
Sensitivity
- < ± 0.3 % - Tolerance
- 1.5 mV/V
Service Temperature
- -30° to 70° C (-22° to 158° F)
Static Lateral Force
- 50 % of Full Scale
Storage Temperature
- -50° to 85° C (-58° to 185° F)
Temperature Coefficient
- < ± 0.035 % of Full Scale/10° C (18° F) - Zero Signal
- < ± 0.05 % of Full Scale/10° C (18° F) - Sensitivity
Temperature Range
- -10° to 45° C (14° to 113° F) - Nominal
Zero Balance
- ± 0.02 mV/V