Description
These high-quality gauges are characterised by their compact and robust design and are primarily used for level measurement on liquid gas tanks.
An optional valve manifold for flange mounting with working pressure indication makes the central measurement of both level and working pressure possible in the one instrument.
The level display can be supplied with an optional, integrated 4 … 20 mA, 2-wire transmitter. Switch contacts for level and working pressure, as well as a transmitter for the working pressure can be retrofitted on site.
Features- Differential pressure measuring ranges from 0 … 80 mbar to 0 ... 1725 mbar.
- High working pressure (Static-Pressure) of 50 bar.
- Overpressure safety either side up to 50 bar.
- Very compact design.
- Optionally compact valve manifold with working pressure indication.
Specifications
Specifications
Nominal Size
- Nominal Size 6" (160 mm) for level indicator
Accuracy Class (± 2.5 % of Full Span)
- 1.0
- 1.6
DP Ranges
- Measuring Cell 1605 inH₂O (4000 mbar): Adj. Span 0…461 inH₂O to 0…1605 inH₂O
- Measuring Cell 923 inH₂O (2300 mbar): Adj. Span 0…260 inH₂O to 0…923 inH₂O
- Measuring Cell 453 inH₂O (1130 mbar): Adj. Span 0…128 inH₂O to 0…453 inH₂O
- Measuring Cell 224 inH₂O (560 mbar): Adj. Span 0…64 inH₂O to 0…224 inH₂O
- Measuring Cell 112 inH₂O (280 mbar): Adj. Span 0…32 inH₂O to 0…112 inH₂O
- Measuring Cell 56 inH₂O (140 mbar): Adj. Span 0…16 inH₂O to 0…56 inH₂O
Maximum Working Pressure
- 725 psi (50 bar)
Overpressure Safety
- 725 psi (50 bar) Either Side
Maximum Ambient Temperature Range
- -40 to +176° F (-40 to +80° C), -40 to +140° F (-40 to +60° C) for oxygen Service
Maximum Media Temperature Range
- -40 to +176° F (-40 to +80° C), -40 to +140° F (-40 to +60° C) for oxygen Service
Ingress Protection
- IP65 per EN/IEC 60529
Measuring Cell Flanges (Wetted)
- v
- Model 712.15: Copper Alloy CW 614N (CuZn₃₉Pb3)
Pressure Elements (Wetted)
- Separating Diaphragm, NBR
- Transmission Parts, Stainless Steel 1.4301 and 1.4305
- Compression spring, Stainless Steel 1.4310
Movement
- Wear Parts Stainless Steel
Dial
- White Aluminum
Pointer
- Adjustable Pointer, Black Aluminum
Case & Bezel
- 304 Stainless Steel, slip-On, secured with clips
Window
- Polycarbonate
Applications
Applications
- Level measurements in closed tanks, particularly in cryotechnology
- Filter monitoring
- Monitoring and control of pumps
- For gaseous and liquid media that are not highly viscous