Model HV100/HV200 Series Isolated Sensor with High EMI Resistance
Description
Wilcoxon’s HV series are innovative accelerometers designed for demanding applications requiring high electrical isolation between the sensor and machine. HV sensors are designed to withstand arcing between the sensor base and its internal electronics to levels as high as 6,000 volts. The sensors offer improved EMI-resistance in areas where high electromagnetic interference occurs such as wind turbines, railway systems and other high-voltage generators.
HV series sensors can pass a HiPot test of > 6,000 volts from sensor electronics to mounting base. This high isolation prevents energy from arcing through the sensor offering better protection of the associated equipment. Improvements in EFT and ESD resistance improves survivability during extreme transient events. The HV series come with a variety of mounting options to ensure compatibility with every application.
Features- Ideal for power generation applications
- Rapid shock recovery
- Hermetically sealed
- Case-base isolation min 6 kV
- EMI-protected
- Manufactured in an approved ISO 9001 facility
Configure
Specifications
Specifications
Approvals & Certifications
- ISO 9001
Approvals & Certifications
- CE
Electrical Connectors
- Cable (J10 / J9T2A)
- Output Connector: 2-Pin MIL-5015 - Model HV200 Series
- Output Connector: 4-Pin M12 - Model HV100 Series
Element
- Sensing Element Design: PZT, Shear
Enclosure, Body Material
- Sensor Case: Stainless Steel
Frequency
- Frequency Response (± 10 %): 1 to 7,000 Hz
- Frequency Response (± 3 dB): 0.5 to 12,000 Hz
- Frequency Response (± 5 %): 3 to 5,000 Hz
- Resonance Frequency: 25 kHz
Input Impedance
- Impedance between Connector & Base (1.0 kHz): > 10 megaohms
- Impedance between Connector & Base (10 kHz): > 1 Megaohm
- Impedance between Connector & Base (100 Hz): > 100 megaohms
- Impedance between Connector & Base (DC): > 100 Gigaohms
Isolation
- Case-Base Isolation: Min. 6 kV
Mounting
- Integral Mounting: M6 x 1.00 x 6.2 mm - Model HV102 & HV202
- Integral Mounting: M8 x 1.25 x 8.4 mm - Model HV100 & HV201
Noise
- Electrical Noise, Equivalent G (Spectral: 10 Hz): 10 µg/√Hz
- Electrical Noise, Equivalent G (Spectral: 100, 1,000 Hz): 5 µg/√Hz
- Electrical Noise, Equivalent. G (Broadband: 2.5 Hz to 25 kHz): 700 µg
Non-Linearity
- Amplitude Non-Linearity: 1 %
Output Impedence
- 100 ohms
Power Requirement
- 18-30 Vdc
- Current Regulating Diode: 2-10 mA
Range
- Acceleration Range, Vdc > 22 V: 80 G Peak
RFI/EMI Protection
- EMI Protected
Seal Type
- Hermetic
Sensitivity
- Base Strain Sensitivity: < 0.0002 G/μstrain
- Electromagnetic Sensitivity, Equivalent G: 70 µg/Gauss
- Sensitivity, ± 5 %, 25° C (77° F): 100 mV/g
- Transverse Sensitivity, Max. 5 % of axial
Shock
- Shock Limit: 5,000 G Peak
Temperature Range
- -40° to 120° C (-40° to 248° F)
Torque
- Mounting Torque, Recommended: 35 In/Lbs (3.4 Nm) - Model HV101, HV102, HV200 & HV202
- Mounting Torque, Recommended: 40 In/Lbs (4.5 Nm) - Model HV100 & HV201
Vibration
- Vibration Limit: 500 G Peak
Voltage
- Bias Output Voltage: 12 Vdc
- Dielectric Withstand Voltage between Connector & Surface: 5,000 Vac (1 Minute)
- Dielectric Withstand Voltage between Connector & Surface: 6,000 Vdc (1 Minute)