Description
Wireless load measuring shackle designed to measure a tension force.
Features- Sturdy design
- Easy to install
- Load pin: stainless steel
- Standard dimensions
- Full range of reception electronics
- Frequencies: from 2.4000 to 2.4835 GHz
- License: exempted
- Power: 10 mW
- Range: 500 m open field
- Antenna: integrated
- Ability to stand by
- Ability of activation by radio
- Remote control of the batteries
- Options:
- External antenna (800 m open field)
- Use in hazardous area (ATEX)
Specifications
Specifications
Applications
- SL-FORCE: Force Measurement on Test Bench
- SL-FORCE: Industrial Weighing
- SL - HOIST: Load Indication on Hoisting Devices & EOT Cranes
Approvals & Certifications
- ATEX
- CE
Capacity
- 1 to 400 T
Consumption
- 65 mA
Current
- 20 µA at Stand-by Mode
Distance
- 1640 feet (500 metres) - Range in an Open Field
Electrical Connectors
- DIN 45322
Enclosure, Body Material
- Stainless Steel
Environmental Protection
- IP65
Excitation Voltage
- 3 Vdc (2 x AA Batteries)
Frequency
- 2.4000 to 2.4835 GHz
Linearity
- Error: < ± 0.5 % (SL-FORCE) to < ± 1 % of Full Scale (SL-HOIST)
Load
- > 300 % to > 500 % of Full Scale - Breaking
Load Limit
- 150 % (SL-FORCE) to 200 % (SL-HOIST) of Full Scale
Power
- 10 mW
Repeatability
- Error: < ± 0.25 % of Full Scale
Sensitivity
- Nominal Sensitivity: 1 to 1.5 mV/V
Service Temperature
- -30° to 70° C (-22° to 158° F)
Static Lateral Force
- 100 % to 150 % of Full Scale
Storage Temperature
- -50° to 85° C (-58° to 185° F)
Temperature Coefficient
- < ± 0.2 % of Full Scale/10° C (18° F)