Images are representations only.

646TUE Series Temperature Switch

Brand: Custom Control Sensors, LLC
Does not ship to OH, United States
The 646TUE Series is a rugged, heavy duty temperature switch with a stainless steel capillary tube and armored jacket probe port fitting.
 
Similar to the 604 Series in design, the 646TUE Series is rated at 15 Amps and UL/CSA explosion proof, Class I, Groups A, B, C and D, and Class II Groups E, F and G certified.
 
It comes with high vibration and shock resistance utilizing Dual Snap® disc spring technology.
Features
  • Adjustable Set Point Range
    • Increasing
      • -30° to 630° F
      • -34° to 332° C
    • Decreasing
      • -39° to 624° F
      • -39° to 329° C
  • Deadband - Approximate
    • At Bottom of Range: 9° to 25° F, 3° to 14° C
    • At Top of Range: 3° to 6° F, 2° to 8° C
  • Probe Temperature Maximum: 200° to 650° F, 93° to 343° C
  • Wetted Materials
    • Temperature Probe: 300 Stainless Steel & Graphite
    • Capillary Tube: 5' Lubricated Glass Fiber
  • Relay: SPDT or DPDT
  • UL, CSA
    • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
  • CE Mark, Dual Seal
The 646TUE Series is a rugged, heavy duty temperature switch with a stainless steel capillary tube and armored jacket probe port fitting.
 
Similar to the 604 Series in design, the 646TUE Series is rated at 15 Amps and UL/CSA explosion proof, Class I, Groups A, B, C and D, and Class II Groups E, F and G certified.
 
It comes with high vibration and shock resistance utilizing Dual Snap® disc spring technology.
Features
  • Adjustable Set Point Range
    • Increasing
      • -30° to 630° F
      • -34° to 332° C
    • Decreasing
      • -39° to 624° F
      • -39° to 329° C
  • Deadband - Approximate
    • At Bottom of Range: 9° to 25° F, 3° to 14° C
    • At Top of Range: 3° to 6° F, 2° to 8° C
  • Probe Temperature Maximum: 200° to 650° F, 93° to 343° C
  • Wetted Materials
    • Temperature Probe: 300 Stainless Steel & Graphite
    • Capillary Tube: 5' Lubricated Glass Fiber
  • Relay: SPDT or DPDT
  • UL, CSA
    • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
  • CE Mark, Dual Seal
Models matching criteria: 63
CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 5` Capillary show more
  • Adjustable Set Point Range
    • Increasing
      • 175° to 310° F
      • 79° to 154° C
    • Decreasing
      • 159° to 305° F
      • 71° to 152° C
  • Deadband  Approximate
    • At Bottom of Range: 16°F, 8°C
    • At Top of Range: 5°F, 2°C
  • Probe Temperature Maximum: 500°F, 260°C
  • Wetted Materials
    • Temperature Probe: 300 Stainless Steel & Graphite
    • Capillary Tube: Lubricated Glass Fiber
  • Relay: SPDT
  • UL, CSA
    • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
  • CE Mark, NACE
1 In Stock
$1,658.36 USD
Does not ship to OH, United States
CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300SST & Graphite Probe,5`Capillary,ATEX/GOST show more
  • Adjustable Set Point Range:
    • Increasing: +90°F to +210°F, +32°C to +99°C
    • Decreasing: +75°F to +205°F, +24°C to +96°C


    • Deadband: Approximately
      • At Bottom of Range: 15°F, 8°C
      • At Top of Range: 5°F, 8°C

    • Probe Temperature (Maximum): +300°F, +149°C
    • Wetted Materials
      • Temperature Probe: 300 Stainless Steel & Graphite
      • Capillary Tube: Lubricated Glass Fiber

    • Relay: SPDT
    • ATEX
      • ATEX Certified For Potentially Explosive Atmospheres Electrical Assembly Series
      • 46-XXXXXXX, Models 6*****, Ex d IIC T6, Directive 94/9/EC Sira #08ATEX 1046X (Option Y)
      • IECEx - SIRA Certified, SIR 10,0193X (Option Y)

    • CE Mark, NACE
    1 In Stock
    $3,008.33 USD
    CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300SST & Graphite Probe,5`Capillary,ATEX/GOST show more
    • Adjustable Set Point Range
      • Increasing
        • 90° to 210° F
        • 32° to 99° C
      • Decreasing
        • 75° to 205° F
        • 24° to 96° C
    • Deadband Approximate
      • At Bottom of Range: 15°F, 8°C
      • At Top of Range: 5°F, 8°C
    • Probe Temperature Maximum: 300°F, 149°C
    • Wetted Materials  
      • Temperature Probe: 300 Stainless Steel & Graphite
      • Capillary Tube: Lubricated Glass Fiber
    • Relay: SPDT
    • ATEX
      • ATEX Certified For Potentially Explosive Atmospheres Electrical Assembly Series
      • 46-XXXXXXX, Models 6*****, Ex d IIC T6, Directive 94/9/EC Sira #08ATEX 1046X (Option Y)
      • IECEx - SIRA Certified, SIR 10,0193X (Option Y)
    • CE Mark, NACE
    1 In Stock
    $3,008.33 USD
    Does not ship to OH, United States
    CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 5` Capillary show more
    • Adjustable Set Point Range:

      • Increasing: +275°F to +420°F, +135°C to +216°C
      • Decreasing: +256°F to +414°F, +124°C to +212°C


      • Deadband: Approximately
        • At Bottom of Range: 19°F, 11°C
        • At Top of Range: 6°F, 4°C

      • Probe Temperature (Maximum): +500°F, +260°C
      • Wetted Materials:
        • Temperature Probe: 300 Stainless Steel & Graphite
        • Capillary Tube: Lubricated Glass Fiber

      • Relay: SPDT
      • UL, CSA
        • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

      • CE Mark, NACE
      Contact For Inventory
      $1,381.85 USD
      Does not ship to OH, United States
      CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 5` Capillary, DPDT show more
      • Adjustable Set Point Range:
        • Increasing: +35°F to +140°F, +2°C to +60°C
        • Decreasing: +21°F to +135°F, -6°C to +57°C
        • Deadband: Approximately
          • At Bottom of Range: 14°F, 8°C
          • At Top of Range: 5°F, 3°C
        • Probe Temperature (Maximum): +300°F, +149°C
        • Wetted Materials:
          • Temperature Probe: 300 Stainless Steel & Graphite
          • Capillary Tube: Lubricated Glass Fiber
        • Relay: DPDT
        • UL, CSA
          • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
        • CE Mark, NACE
        10 - 12 weeks
        $1,436.71 USD
        Does not ship to OH, United States
        Non-Cancellable / Non-Refundable
        CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 5` Capillary, DPDT show more
        • Adjustable Set Point Range:
          • Increasing: +90°F to +210°F, +32°C to +99°C
          • Decreasing: +75°F to +195°F, +24°C to +91°C
          • Deadband: Approximately
            • At Bottom of Range: 15°F, 8°C
            • At Top of Range: 5°F, 8°C
          • Probe Temperature (Maximum): +300°F, +149°C
          • Wetted Materials:
            • Temperature Probe: 300 Stainless Steel & Graphite
            • Capillary Tube: Lubricated Glass Fiber
          • Relay: DPDT
          • UL, CSA
            • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
          • CE Mark, NACE
          10 - 12 weeks
          $1,436.71 USD
          Does not ship to OH, United States
          Non-Cancellable / Non-Refundable
          CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 5` Capillary, DPDT show more
          • Adjustable Set Point Range:
            • Increasing: +175°F to +310°F, +79°C to +154°C
            • Decreasing: +159°F to +305°F, +71°C to +152°C
            • Deadband: Approximately
              • At Bottom of Range: 16°F, 8°C
              • At Top of Range: 5°F, 2°C
            • Probe Temperature (Maximum): +500°F, +260°C
            • Wetted Materials:
              • Temperature Probe: 300 Stainless Steel & Graphite
              • Capillary Tube: 5' Lubricated Glass Fiber
            • Relay: DPDT
            • UL, CSA
              • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
            • CE Mark, NACE
            10 - 12 weeks
            $1,436.71 USD
            Does not ship to OH, United States
            Non-Cancellable / Non-Refundable
            CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 5` Capillary, DPDT show more
            • Adjustable Set Point Range:
              • Increasing: +275°F to +420°F, +135°C to +216°C
              • Decreasing: +256°F to +414°F, +124°C to +212°C
              • Deadband: Approximately
                • At Bottom of Range: 19°F, 11°C
                • At Top of Range: 6°F, 4°C
              • Probe Temperature (Maximum): +500°F, +260°C
              • Wetted Materials:
                • Temperature Probe: 300 Stainless Steel & Graphite
                • Capillary Tube: 5' Lubricated Glass Fiber
              • Relay: DPDT
              • UL, CSA
                • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
              • CE Mark, NACE
              10 - 12 weeks
              $1,436.71 USD
              Does not ship to OH, United States
              Non-Cancellable / Non-Refundable
              CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 5` Capillary, DPDT show more
              • Adjustable Set Point Range:
                • Increasing: +380°F to +525°F, +193°C to +274°C
                • Decreasing: +355°F to +520°F, +179°C to +271°C
                • Deadband: Approximately
                  • At Bottom of Range: 25°F, 14°C
                  • At Top of Range: 5°F, 3°C
                • Probe Temperature (Maximum): +600°F, +316°C
                • Wetted Materials:
                  • Temperature Probe: 300 Stainless Steel & Graphite
                  • Capillary Tube: Lubricated Glass Fiber
                • Relay: DPDT
                • UL, CSA
                  • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
                • CE Mark, NACE
                10 - 12 weeks
                $1,436.71 USD
                Does not ship to OH, United States
                Non-Cancellable / Non-Refundable
                CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 5` Capillary show more
                • Adjustable Set Point Range:

                  • Increasing: -30°F to +55°F, -34°C to +13°C
                  • Decreasing: -39°F to +52°F, -39°C to +11°C


                  • Deadband: Approximately
                    • At Bottom of Range: 9°F, 3°C
                    • At Top of Range: 3°F, 2°C

                  • Probe Temperature (Maximum): +200°F, +93°C
                  • Wetted Materials:
                    • Temperature Probe: 300 Stainless Steel & Graphite
                    • Capillary Tube: 5' Lubricated Glass Fiber

                  • Relay: SPDT
                  • UL, CSA
                    • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

                  • CE Mark, NACE
                  10 - 12 weeks
                  $1,658.36 USD
                  Does not ship to OH, United States
                  CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 5` Capillary show more
                  • Adjustable Set Point Range:

                    • Increasing: +35°F to +140°F, +2°C to +60°C
                    • Decreasing: +21°F to +135°F, -6°C to +57°C


                    • Deadband: Approximately
                      • At Bottom of Range: 14°F, 8°C
                      • At Top of Range: 5°F, 3°C

                    • Probe Temperature (Maximum): +300°F, +149°C
                    • Wetted Materials:
                      • Temperature Probe: 300 Stainless Steel & Graphite
                      • Capillary Tube: 5' Lubricated Glass Fiber

                    • Relay: SPDT
                    • UL, CSA
                      • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

                    • CE Mark, NACE
                    10 - 12 weeks
                    $1,658.36 USD
                    Does not ship to OH, United States
                    CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 5` Capillary show more
                    • Adjustable Set Point Range:

                      • Increasing: +90°F to +210°F, +32°C to +99°C
                      • Decreasing: +75°F to +195°F, +24°C to +91°C



                      • Deadband: Approximately
                        • At Bottom of Range: 15°F, 8°C
                        • At Top of Range: 5°F, 8°C

                      • Probe Temperature (Maximum): +300°F, +149°C
                      • Wetted Materials:
                        • Temperature Probe: 300 Stainless Steel & Graphite
                        • Capillary Tube: Lubricated Glass Fiber

                      • Relay: SPDT
                      • UL, CSA
                        • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

                      • CE Mark, NACE
                      Contact For Inventory
                      $1,658.36 USD
                      CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 10` Capillary show more
                      • Adjustable Set Point Range:

                        • Increasing: +90°F to +210°F, +32°C to +99°C
                        • Decreasing: +75°F to +205°F, +24°C to +96°

                      • Deadband: Approximately
                        • At Bottom of Range: 15°F, 8°C
                        • At Top of Range: 5°F, 3°C

                      • Probe Temperature (Maximum): +300°F, +149°C
                      • Wetted Materials:
                        • Temperature Probe: 300 Stainless Steel & Graphite
                        • Capillary Tube: 10' Capillary, Lubricated Glass Fiber

                      • Relay: SPDT
                      • UL, CSA
                        • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

                      • CE Mark, NACE
                      Contact For Inventory
                      $2,677.70 USD
                      Does not ship to OH, United States
                      CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 5` Capillary show more
                      • Adjustable Set Point Range:
                        • Increasing: +380°F to +525°F, +193°C to +274°C
                        • Decreasing: +355°F to +520°F, +179°C to +271°C
                        • Deadband: Approximately
                          • At Bottom of Range: 25°F, 14°C
                          • At Top of Range: 5°F, 3°C
                        • Probe Temperature (Maximum): +600°F, +316°C
                        • Wetted Materials:
                          • Temperature Probe: 300 Stainless Steel & Graphite
                          • Capillary Tube: Lubricated Glass Fiber
                        • Relay: SPDT
                        • UL, CSA
                          • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
                        • CE Mark, NACE
                        10 - 12 weeks
                        $2,734.04 USD
                        Does not ship to OH, United States
                        CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 10` Capillary, DPDT show more
                        • Adjustable Set Point Range:

                          • Increasing: +90°F to +210°F, +32°C to +99°C
                          • Decreasing: +75°F to +195°F, +24°C to +91°C


                          • Deadband: Approximately
                            • At Bottom of Range: 15°F, 8°C
                            • At Top of Range: 5°F, 8°C

                          • Probe Temperature (Maximum): +300°F, +149°C
                          • Wetted Materials:
                            • Temperature Probe: 300 Stainless Steel & Graphite
                            • Capillary Tube: 10' Capillary, Lubricated Glass Fiber

                          • Relay: DPDT
                          • UL, CSA
                            • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

                          • CE Mark, NACE
                          7 - 9 weeks
                          $2,745.90 USD
                          Does not ship to OH, United States
                          CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 10` Capillary show more
                          • Adjustable Set Point Range:
                            • Increasing: +35°F to +140°F, +2°C to +60°C
                            • Decreasing: +21°F to +135°F, -6°C to +57°C
                            • Deadband: Approximately
                              • At Bottom of Range: 14°F, 8°C
                              • At Top of Range: 5°F, 3°C
                            • Probe Temperature (Maximum): +300°F, +149°C
                            • Wetted Materials:
                              • Temperature Probe: 300 Stainless Steel & Graphite
                              • Capillary Tube: 10' Lubricated Glass Fiber
                            • Relay: SPDT
                            • UL, CSA
                              • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
                            • CE Mark, NACE
                            10 - 12 weeks
                            $2,775.55 USD
                            Does not ship to OH, United States
                            CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 10` Capillary show more
                            • Adjustable Set Point Range:

                              • Increasing: +380°F to +525°F, +193°C to +274°C
                              • Decreasing: +355°F to +520°F, +179°C to +271°C


                              • Deadband: Approximately
                                • At Bottom of Range: 25°F, 14 Degrees°C
                                • At Top of Range: 5°F, 3°C

                              • Probe Temperature (Maximum): +600°F, +316°C
                              • Wetted Materials:
                                • Temperature Probe: 300 Stainless Steel & Graphite
                                • Capillary Tube: 10' Capillary, Lubricated Glass Fiber

                              • Relay: SPDT
                              • UL, CSA
                                • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

                              • CE Mark, NACE
                              Contact For Inventory
                              $2,775.55 USD
                              Does not ship to OH, United States
                              CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 15` Capillary, DPDT show more
                              • Adjustable Set Point Range:
                                • Increasing: +35°F to +140°F, +2°C to +60°C
                                • Decreasing: +21°F to +135°F, -6°C to +57°C
                                • Deadband: Approximately
                                  • At Bottom of Range: 14°F, 8°C
                                  • At Top of Range: 5°F, 3°C
                                • Probe Temperature (Maximum): +300°F, +149°C
                                • Wetted Materials:
                                  • Temperature Probe: 300 Stainless Steel & Graphite
                                  • Capillary Tube: 15' Capillary, Lubricated Glass Fiber
                                • Relay: DPDT
                                • UL, CSA
                                  • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
                                • CE Mark, NACE
                                10 - 12 weeks
                                $2,775.55 USD
                                Does not ship to OH, United States
                                Non-Cancellable / Non-Refundable
                                CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 15` Capillary show more
                                • Adjustable Set Point Range:
                                  • Increasing: +90°F to +210°F, +32°C to +99°C
                                  • Decreasing: +75°F to +195°F, +24°C to +91°C
                                  • Deadband: Approximately
                                    • At Bottom of Range: 15°F, 8°C
                                    • At Top of Range: 5°F, 8°C
                                  • Probe Temperature (Maximum): +300°F, +149°C
                                  • Wetted Materials:
                                    • Temperature Probe: 300 Stainless Steel & Graphite
                                    • Capillary Tube: Lubricated Glass Fiber
                                  • Relay: SPDT
                                  • UL, CSA
                                    • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
                                  • CE Mark, NACE
                                  10 - 12 weeks
                                  $2,784.45 USD
                                  Does not ship to OH, United States
                                  Non-Cancellable / Non-Refundable
                                  CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 15` Capillary show more
                                  • Adjustable Set Point Range:
                                    • Increasing: +380°F to +525°F, +193°C to +274°C
                                    • Decreasing: +355°F to +520°F, +179°C to +271°C
                                    • Deadband: Approximately
                                      • At Bottom of Range: 25°F, 14°C
                                      • At Top of Range: 5°F, 3°C
                                    • Probe Temperature (Maximum): +600°F, +316°C
                                    • Wetted Materials:
                                      • Temperature Probe: 300 Stainless Steel & Graphite
                                      • Capillary Tube: 15' Capillary, Lubricated Glass Fiber
                                    • Relay: SPDT
                                    • UL, CSA
                                      • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
                                    • CE Mark, NACE
                                    10 - 12 weeks
                                    $2,793.35 USD
                                    Does not ship to OH, United States
                                    Non-Cancellable / Non-Refundable
                                    CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 10` Capillary, DPDT show more
                                    • Adjustable Set Point Range:
                                      • Increasing: +35°F to +140°F, +2°C to +60°C
                                      • Decreasing: +21°F to +135°F, -6°C to +57°C
                                      • Deadband: Approximately
                                        • At Bottom of Range: 14°F, 8°C
                                        • At Top of Range: 5°F, 3°C
                                      • Probe Temperature (Maximum): +300°F, +149°C
                                      • Wetted Materials:
                                        • Temperature Probe: 300 Stainless Steel & Graphite
                                        • Capillary Tube: 10' Capillary, Lubricated Glass Fiber
                                      • Relay: DPDT
                                      • UL, CSA
                                        • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
                                      • CE Mark, NACE
                                      10 - 12 weeks
                                      $2,799.28 USD
                                      Does not ship to OH, United States
                                      Non-Cancellable / Non-Refundable
                                      CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 10` Capillary, DPDT show more
                                      • Adjustable Set Point Range:
                                        • Increasing: -30°F to +55°F, -34°C to +13°C
                                        • Decreasing: -39°F to +52°F, -39°C to +11°C
                                        • Deadband: Approximately
                                          • At Bottom of Range: 9°F, 3°C
                                          • At Top of Range: 3°F, 2°C
                                        • Probe Temperature (Maximum): +200°F, +93°C
                                        • Wetted Materials:
                                          • Temperature Probe: 300 Stainless Steel & Graphite
                                          • Capillary Tube:10' Capillary, Lubricated Glass Fiber
                                        • Relay: DPDT
                                        • UL, CSA
                                          • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
                                        • CE Mark, NACE
                                        10 - 12 weeks
                                        $2,825.96 USD
                                        Does not ship to OH, United States
                                        Non-Cancellable / Non-Refundable
                                        CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300SST&GraphiteProbe,5`Capillary,GoldContacts show more
                                        • Adjustable Set Point Range:
                                          • Increasing: +175°F to +310°F, +79°C to +154°C
                                          • Decreasing: +159°F to +305°F, +71°C to +152°C
                                          • Deadband: Approximately
                                            • At Bottom of Range: 16°F, 8°C
                                            • At Top of Range: 5°F, 2°C
                                          • Probe Temperature (Maximum): +500°F, +260°C
                                          • Wetted Materials:
                                            • Temperature Probe: 300 Stainless Steel & Graphite
                                            • Capillary Tube: Lubricated Glass Fiber
                                          • Relay: SPDT
                                          • UL, CSA
                                            • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
                                          • CE Mark, NACE
                                          10 - 12 weeks
                                          $2,830.41 USD
                                          Does not ship to OH, United States
                                          Non-Cancellable / Non-Refundable
                                          CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 25` Capillary show more
                                          • Adjustable Set Point Range:

                                            • Increasing: +90°F to +210°F, +32°C to +99°C
                                            • Decreasing: +75°F to +195°F, +24°C to +91°C



                                            • Deadband: Approximately
                                              • At Bottom of Range: 15°F, 8°C
                                              • At Top of Range: 5°F, 8°C

                                            • Probe Temperature (Maximum): +300°F, +149°C
                                            • Wetted Materials:
                                              • Temperature Probe: 300 Stainless Steel & Graphite
                                              • Capillary Tube: Lubricated Glass Fiber

                                            • Relay: SPDT
                                            • UL, CSA
                                              • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

                                            • CE Mark, NACE
                                            10 - 12 weeks
                                            $2,855.62 USD
                                            Does not ship to OH, United States
                                            Non-Cancellable / Non-Refundable
                                            CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 25` Capillary show more
                                            • Adjustable Set Point Range:
                                              • Increasing: +35°F to +140°F, +2°C to +60°C
                                              • Decreasing: +21°F to +135°F, -6°C to +57°C
                                              • Deadband: Approximately
                                                • At Bottom of Range: 14°F, 8°C
                                                • At Top of Range: 5°F, 3°C
                                              • Probe Temperature (Maximum): +300°F, +149°C
                                              • Wetted Materials:
                                                • Temperature Probe: 300 Stainless Steel & Graphite
                                                • Capillary Tube: 25' Lubricated Glass Fiber
                                              • Relay: SPDT
                                              • UL, CSA
                                                • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
                                              • CE Mark, NACE
                                              10 - 12 weeks
                                              $2,866.00 USD
                                              Does not ship to OH, United States
                                              Non-Cancellable / Non-Refundable
                                              CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 5` Capillary, DPDT show more
                                              • Adjustable Set Point Range:
                                                • Increasing: -30°F to +55°F, -34°C to +13°C
                                                • Decreasing: -39°F to +52°F, -39°C to +11°C
                                              • Deadband: Approximately
                                                • At Bottom of Range: 9°F, 3°C
                                                • At Top of Range: 3°F, 2°C
                                              • Probe Temperature (Maximum): +200°F, +93°C
                                              • Wetted Materials:
                                                • Temperature Probe: 300 Stainless Steel & Graphite
                                                • Capillary Tube: 5' Lubricated Glass Fiber
                                              • Relay: DPDT
                                              • UL, CSA
                                                • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
                                              • CE Mark, NACE
                                              10 - 12 weeks
                                              $2,888.24 USD
                                              Does not ship to OH, United States
                                              Non-Cancellable / Non-Refundable
                                              CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 25` Capillary, DPDT show more
                                              • Adjustable Set Point Range:

                                                • Increasing: +90°F to +210°F, +32°C to +99°C
                                                • Decreasing: +75°F to +195°F, +24°C to +91°C


                                                • Deadband: Approximately
                                                  • At Bottom of Range: 15°F, 8°C
                                                  • At Top of Range: 5°F, 8°C

                                                • Probe Temperature (Maximum): +300°F, +149°C
                                                • Wetted Materials:
                                                  • Temperature Probe: 300 Stainless Steel & Graphite
                                                  • Capillary Tube: 25' Capillary, Lubricated Glass Fiber

                                                • Relay: DPDT
                                                • UL, CSA
                                                  • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

                                                • CE Mark, NACE
                                                10 - 12 weeks
                                                $2,923.82 USD
                                                Does not ship to OH, United States
                                                Non-Cancellable / Non-Refundable
                                                CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 25` Capillary, DPDT show more
                                                • Adjustable Set Point Range:
                                                  • Increasing: +35°F to +140°F, +2°C to +60°C
                                                  • Decreasing: +21°F to +135°F, -6°C to +57°C

                                                • Deadband: Approximately
                                                  • At Bottom of Range: 14°F, 8°C
                                                  • At Top of Range: 5°F, 3°C

                                                • Probe Temperature (Maximum): +300°F, +149°C
                                                • Wetted Materials:
                                                  • Temperature Probe: 300 Stainless Steel & Graphite
                                                  • Capillary Tube: 25' Lubricated Glass Fiber

                                                • Relay: DPDT
                                                • UL, CSA
                                                  • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

                                                • CE Mark, NACE
                                                10 - 12 weeks
                                                $2,934.20 USD
                                                Does not ship to OH, United States
                                                CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 10` Capillary show more
                                                • Adjustable Set Point Range:

                                                  • Increasing: -30°F to +55°F, -34°C to +13°C
                                                  • Decreasing: -39°F to +52°F, -39°C to +11°C


                                                  • Deadband: Approximately
                                                    • At Bottom of Range: 9°F, 3°C
                                                    • At Top of Range: 3°F, 2°C

                                                  • Probe Temperature (Maximum): +200°F, +93°C
                                                  • Wetted Materials:
                                                    • Temperature Probe: 300 Stainless Steel & Graphite
                                                    • Capillary Tube: 10' Lubricated Glass Fiber

                                                  • Relay: SPDT
                                                  • UL, CSA
                                                    • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

                                                  • CE Mark, NACE
                                                  10 - 12 weeks
                                                  $2,987.58 USD
                                                  Does not ship to OH, United States
                                                  CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 15` Capillary show more
                                                  • Adjustable Set Point Range:
                                                    • Increasing: +35°F to +140°F, +2°C to +60°C
                                                    • Decreasing: +21°F to +135°F, -6°C to +57°C
                                                    • Deadband: Approximately
                                                      • At Bottom of Range: 14°F, 8°C
                                                      • At Top of Range: 5°F, 3° C
                                                    • Probe Temperature (Maximum): +300°F, +149°C
                                                    • Wetted Materials:
                                                      • Temperature Probe: 300 Stainless Steel & Graphite
                                                      • Capillary Tube: 15' Lubricated Glass Fiber
                                                    • Relay: SPDT
                                                    • UL, CSA
                                                      • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
                                                    • CE Mark, NACE
                                                    10 - 12 weeks
                                                    $3,352.31 USD
                                                    Does not ship to OH, United States
                                                    Non-Cancellable / Non-Refundable
                                                    CCS DUAL-SNAP Temp. Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 5` Capillary,GoldContacts show more
                                                    • Adjustable Set Point Range:

                                                      • Increasing: +90°F to +210°F, +32°C to +99°C
                                                      • Decreasing: +75°F +195°F, +24°C to +91°C

                                                    • Deadband: Approximately
                                                      • At Bottom of Range: 15°F, 8°C
                                                      • At Top of Range: 5°F, 8°C

                                                    • Probe Temperature (Maximum): +300°F, +149°C
                                                    • Wetted Materials:
                                                      • Temperature Probe: 300 Stainless Steel & Graphite
                                                      • Capillary Tube: Lubricated Glass Fiber

                                                    • Relay: SPDT
                                                    • Contacts: Gold
                                                    • UL, CSA
                                                      • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

                                                    • CE Mark, NACE
                                                    18 - 20 weeks
                                                    $3,533.94 USD
                                                    Does not ship to OH, United States
                                                    CCS DUAL-SNAP Temp. Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 5` Capillary,GoldContacts show more
                                                    • Adjustable Set Point Range:
                                                      • Increasing: +35°F to +140°F, +2°C to +60°C
                                                      • Decreasing: +21°F to +135°F, -6°C to +57°C
                                                      • Deadband: Approximately
                                                        • At Bottom of Range: 14°F, 8°C
                                                        • At Top of Range: 5°F, 3°C
                                                      • Probe Temperature (Maximum): +300°F, +149°C
                                                      • Wetted Materials:
                                                        • Temperature Probe: 300 Stainless Steel & Graphite
                                                        • Capillary Tube: 5' Lubricated Glass Fiber
                                                      • Relay: SPDT
                                                      • Contacts: Gold
                                                      • UL, CSA
                                                        • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
                                                      • CE Mark, NACE
                                                      10 - 12 weeks
                                                      $3,546.54 USD
                                                      Does not ship to OH, United States
                                                      Non-Cancellable / Non-Refundable
                                                      CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 5` Capillary show more
                                                      • Adjustable Set Point Range:
                                                        • Increasing: +480°F to +630°F, +249°C to +332°C
                                                        • Decreasing: +456°F to +624°F, +236°C to +329°C
                                                        • Deadband: Approximately
                                                          • At Bottom of Range: 24°F, 13°C
                                                          • At Top of Range: 6°F, 7°C
                                                        • Probe Temperature (Maximum): +650°F, +343°C
                                                        • Wetted Materials:
                                                          • Temperature Probe: 300 Stainless Steel & Graphite
                                                          • Capillary Tube: Lubricated Glass Fiber
                                                        • Relay: SPDT
                                                        • UL, CSA
                                                          • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
                                                        • CE Mark, NACE
                                                        24 - 26 weeks
                                                        $3,669.60 USD
                                                        Does not ship to OH, United States
                                                        CCS DUAL-SNAP Temperature Switch, Hazardous Area, 1/2" NPT 300 SST & Graphite Probe, 5' Capillary
                                                        Contact For Inventory
                                                        Does not ship to OH, United States
                                                        Log In to See Pricing
                                                        CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 10` Capillary show more
                                                        • Adjustable Set Point Range:

                                                          • Increasing: +175°F to +310°F, +79°C to +154°C
                                                          • Decreasing: +159°F to +305°F, +71°C to +152°C



                                                          • Deadband: Approximately
                                                            • At Bottom of Range: 16°F, 8°C
                                                            • At Top of Range: 5°F, 2°C

                                                          • Probe Temperature (Maximum): +500°F, +260°C
                                                          • Wetted Materials:
                                                            • Temperature Probe: 300 Stainless Steel & Graphite
                                                            • Capillary Tube: 10' Capillary, Lubricated Glass Fiber

                                                          • Relay: SPDT
                                                          • UL, CSA
                                                            • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

                                                          • CE Mark, NACE
                                                          10 - 12 weeks
                                                          Does not ship to OH, United States
                                                          CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 15` Capillary show more
                                                          • Adjustable Set Point Range:
                                                            • Increasing: +175°F to +310°F, +79°C to +154°C
                                                            • Decreasing: +159°F to +305°F, +71°C to +152°C


                                                            • Deadband: Approximately
                                                              • At Bottom of Range: 16°F, 8°C
                                                              • At Top of Range: 5°F, 2°C

                                                            • Probe Temperature (Maximum): +500°F, +260°C
                                                            • Wetted Materials:
                                                              • Temperature Probe: 300 Stainless Steel & Graphite
                                                              • Capillary Tube: 15' Capillary, Lubricated Glass Fiber

                                                            • Relay: SPDT
                                                            • UL, CSA
                                                              • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

                                                            • CE Mark, NACE
                                                            10 - 12 weeks
                                                            Does not ship to OH, United States
                                                            CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 15` Capillary show more
                                                            • Adjustable Set Point Range:
                                                              • Increasing: +275°F to +420°F, +135°C to +216°C
                                                              • Decreasing: +256°F to +414°F, +124°C to +212°C
                                                            • Deadband: Approximately
                                                              • At Bottom of Range: 19°F, 11°C
                                                              • At Top of Range: 6°F, 4°C
                                                            • Probe Temperature (Maximum): +500°F, +260°C
                                                            • Wetted Materials:
                                                              • Temperature Probe: 300 Stainless Steel & Graphite
                                                              • Capillary Tube: 15' Capillary, Lubricated Glass Fiber
                                                            • Relay: SPDT
                                                            • UL, CSA
                                                              • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
                                                            • CE Mark, NACE
                                                            10 - 12 weeks
                                                            Does not ship to OH, United States
                                                            CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 15` Capillary show more
                                                            • Adjustable Set Point Range:
                                                              • Increasing: +480°F to +630°F, +249°C to +332°C
                                                              • Decreasing: +456°F to +624°F, +236°C to +329°C
                                                              • Deadband: Approximately
                                                                • At Bottom of Range: 24°F, 13°C
                                                                • At Top of Range: 6°F, 7°C
                                                              • Probe Temperature (Maximum): +650°F, +343°C
                                                              • Wetted Materials:
                                                                • Temperature Probe: 300 Stainless Steel & Graphite
                                                                • Capillary Tube: 15' Capillary, Lubricated Glass Fiber
                                                              • Relay: SPDT
                                                              • UL, CSA
                                                                • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D
                                                              • CE Mark, NACE
                                                              10 - 12 weeks
                                                              Does not ship to OH, United States
                                                              CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 18" Free Leads, DPDT show more
                                                              • Adjustable Set Point Range:
                                                                • Increasing: -30°F to +55°F, -34°C to +13°C
                                                                • Decreasing: -39°F to +52°F, -39°C to +11°C

                                                              • Deadband: Approximately
                                                                • At Bottom of Range: 9°F, 3°C
                                                                • At Top of Range: 3°F, 2°C

                                                              • Probe Temperature (Maximum): +200°F, +93°C
                                                              • Wetted Materials:
                                                                • Temperature Probe: 300 Stainless Steel & Graphite
                                                                • Capillary Tube: 5' Lubricated Glass Fiber

                                                              • Free Leads: 18" Teflon
                                                              • Relay: DPDT
                                                              • UL, CSA
                                                                • Explosion Proof - Class 1, Div/Zone 1, Groups A, B, C and D

                                                              • CE Mark, NACE
                                                              10 - 12 weeks
                                                              Does not ship to OH, United States
                                                              CCS DUAL-SNAP Temperature Switch, Haz. Area, 1/2" NPT 300 SST & Graphite Probe, 5` Capillary
                                                              10 - 12 weeks
                                                              Does not ship to OH, United States

                                                              Specifications

                                                              Adjustment Type

                                                              • Field Adjustable

                                                              Approvals & Certifications

                                                              • ATEX
                                                              • CE
                                                              • CRN
                                                              • CRN - Alberta
                                                              • CRN - British Columbia
                                                              • CRN - Manitoba
                                                              • CRN - N.W. Territories
                                                              • CRN - Saskatchewan
                                                              • CSA
                                                              • cUL
                                                              • Dual Seal
                                                              • EMC
                                                              • LVD
                                                              • PED
                                                              • RoHS
                                                              • RTN
                                                              • UL

                                                              Capillary Length

                                                              • 10 feet (3 metres)
                                                              • 15 feet
                                                              • 25 feet
                                                              • 5 feet (1.524 metres)

                                                              Capillary Material

                                                              • Lubricated Glass Fiber

                                                              Deadband, Approximate - Bottom of Range

                                                              • -13° to -4° C (9° to 25° F)
                                                              • 5° to 14° C (41° to 57° F)

                                                              Deadband, Approximate - Top of Range

                                                              • -16° to -14° C (3° to 6° F)
                                                              • 2° to 8° C (36° to 46° F)

                                                              Electrical - Free Leads

                                                              • 18” (45 cm) Free Leads
                                                              • 18” (45 cm) Teflon Leadwire

                                                              Electrical Assembly

                                                              • Hermetic Seal

                                                              Electrical Certification

                                                              • ATEX - Baseefa Certified for Potentially Explosive Atmospheres. Models 646**Y, II 2 GD Ex d IIC, Ex Tb IIIC, Baseefa 05-ATEX-0011X. (Option Y)
                                                              • c-UL, UL/CSA Explosion-proof: Div. 1, 2 Hermetically Sealed Electrical Assembly P/N 17-51 (17-73 for M Model Option), Listed by Both Underwriter’s Laboratories, Inc. (File No. E32961) & Canadian Standard Association (CSA)Testing Laboratories (File No. L

                                                              Electrical Connectors

                                                              • 1/2” NPT Male

                                                              Electrical Contacts

                                                              • Gold
                                                              • Silver

                                                              Electrical Rating

                                                              • 1 A at 125 Vac, 50/60 Hz
                                                              • 15 A at 125/250/480 Vac Resistive, 0.5 A at 125 Vdc, 250 A at Vdc
                                                              • 5 A at 125/250 Vac Resisitive, 5 A at 28 Vdc, 0.5 A at 125 Vdc

                                                              Enclosure, Body Material

                                                              • Aluminum

                                                              Environmental Protection

                                                              • IP54
                                                              • IP66
                                                              • NEMA 13
                                                              • NEMA 4, 7, 9, 13 / IP54, 66
                                                              • NEMA 7
                                                              • NEMA 9

                                                              Maximum Sensor, Probe Temperature

                                                              • 93° to 343° C (200° to 650° F)

                                                              NACE & NIST

                                                              • NACE MR-0175: 2003

                                                              NPT Connection

                                                              • 1/2” NPT Male

                                                              O-Ring Material

                                                              • None

                                                              Operating Temperature

                                                              • -40° to 86° C (-40° to 187° F)

                                                              Proof Pressure

                                                              • bar: 103.4
                                                              • kPa: 10,342
                                                              • psig: 1,500

                                                              Sensor, Probe Material

                                                              • Stainless Steel & Graphite

                                                              Set Point - Decreasing

                                                              • -39° to 329° C
                                                              • -39° to 329° C (-38° to 624° F)

                                                              Set Point - Increasing

                                                              • -34° to 332° C
                                                              • -34° to 332° C (-29° to 630° F)

                                                              Switch Type

                                                              • DPDT
                                                              • SPDT

                                                              System Pressure

                                                              • bar: 86
                                                              • kPa: 8,618
                                                              • psig: 1,250

                                                              Applications

                                                              • Oil & Gas
                                                              • Power Generation
                                                              • Fluid Management[
                                                              • Chemical Refining and Processing
                                                              • Manufacturing Process
                                                              • Utilities, Water Treatment and Waste
                                                              • Safety Systems