Description
Custom made load pin designed to be installed at the same place of a common axle without big change of the existing mechanical environment. Verison model 5000 only available with a diameter smaller or equal than 39 mm and with axial cable.
Features- CE certified for hoisting applications
- Sturdy Design
- Stainless steel
- Protection IP 65
- Cable length: 6 m
- Available options (non exhaustive list):
- ATEX intrinsic safety Ex II 1GD Ex ia IIC T6 or T4 Ga Ex ia IIIC T80° C Da
- High service temperature (180° C)
- Amplified output (V or mA) and digital output signal (RS-232C, RS-485, USB)
Specifications
Specifications
Applications
- Force Measurement on Cylinders/Industrial Weighing
- Hoisting Devices & Crane's Security in Combination with a Load Limitation Electronics
Approvals & Certifications
- ATEX Intrinsic Safety Ex II 1 GD Ex ia IIC T6 or T4 Ga Ex ia IIIC T80° C Da
- CE Hoisting
- CSA
- IECEx
Cable Length
- 20 feet (6 metres)
Capacity
- 0.5 to 6.3 T
Communication
- RS-232C, RS-485
- USB
Enclosure, Body Material
- Stainless Steel
Environmental Protection
- IP65
Excitation Voltage
- 10 Vdc
- 3-12 Vdc - Nominal Range
Insulation Resistance
- > 5,000 megaohms
Load
- Breaking Load: > 300 % to > 500 % of Full Scale
- Permissible Dynamic Loading: 50 % to 75 % of Full Scale
Load Limit
- 150 % of Full Scale
- 200 % of Full Scale
Repeatability
- Error: < ± 0.25 % of Full Scale
Resistance
- Input/Output: 352 ± 2 ohms
Sensitivity
- 1 mV/V (SL-Hoist)
- 1.5 mV/V (SL-Force)
- Sensitivity Tolerance: < ± 0.5 %
Service Temperature
- -30° to 70° C (-22° to 158° F)
Static Lateral Force
- 100 % of Full Scale
- 150 % of Full Scale
Storage Temperature
- -50° to 85° C (-58° to 185° F)
Temperature Coefficient
- < ± 0.2 % of Full Scale/10° C (18° F)
Zero Balance
- ± 0.02 mV/V