Images are representations only.

5190/5195 Through Hole (Annular) Heavy Capacity Load Cell

Brand: Sensy - Sensors & Synergy S.A.
Annular compression load cell.
Features
  • Low-Profile for high capacity load cells
  • Material: stainless steel (5190) or nickel plated steel (5195)
  • Protection IP 65
  • Sturdy design
  • Cable length: 3 to 20 meters
  • Available options:
    • Custom made dimensions
    • High service temperature (up to 180° C)
    • ATEX intrinsic safety Ex II 1GD Ex ia IIC T6 or T4 Ga Ex ia IIIC T80° C Da
    • Redundant dual Wheatstone bridge
    • Amplified output (V or mA) and digital output signal (RS-232C, RS-485, USB)
show more
Annular compression load cell.
Features
  • Low-Profile for high capacity load cells
  • Material: stainless steel (5190) or nickel plated steel (5195)
  • Protection IP 65
  • Sturdy design
  • Cable length: 3 to 20 meters
  • Available options:
    • Custom made dimensions
    • High service temperature (up to 180° C)
    • ATEX intrinsic safety Ex II 1GD Ex ia IIC T6 or T4 Ga Ex ia IIIC T80° C Da
    • Redundant dual Wheatstone bridge
    • Amplified output (V or mA) and digital output signal (RS-232C, RS-485, USB)

Specifications

Applications

  • Pre-Stressed Rods Measurement (Concrete, Snow, Ground, Rocks)

Approvals & Certifications

  • ATEX Intrinsic Safety Ex II 1 GD Ex ia IIC T6 or T4 Ga Ex ia IIIC T80° C Da
  • CE

Cable Length

  • 10 to 66 feet (3 to 20 metres)

Capacity

  • 20 to 2000 T

Communication

  • RS-232C, RS-485
  • USB

Electrical Connectors

  • DIN 45322

Enclosure, Body Material

  • Nickel-Plated Steel
  • Stainless Steel

Environmental Protection

  • IP65

Excitation Voltage

  • 10 Vdc
  • 3-12 Vdc - Nominal Range

Insulation Resistance

  • > 5,000 megaohms

Load

  • > 300 % of Full Scale - Breaking Load
  • 50 % of Full Scale - Permissible Dynamic Loading

Load Limit

  • 150 % of Full Scale

Repeatability

  • Error: < ± 0.25 % of Full Scale

Resistance

  • Input/Output: 702 ± 2 ohms

Sensitivity

  • Nominal Sensitivity: 1.5 mV/V

Service Temperature

  • -30° to 70° C (-22° to 158° F)

Static Lateral Force

  • 25 % of Full Scale

Storage Temperature

  • -50° to 85° C (-58° to 185° F)

Temperature Coefficient

  • < ± 0.2 % of Full Scale/10° C (18° F)

Zero Balance

  • ± 0.02 mV/V