Images are representations only.

IM Series Interface Module

Brand: Turck, Inc

TURCK's IM series of Isolating Intrinsically Safe Barriers is designed to be a simple and safe way to solve the
problems associated with the installation of equipment that is used in potentially explosive atmospheres.

TURCK's IM series uses the intrinsically safe concept that is universally accepted, easy to apply and the safest
way to install electronic measuring, monitoring and control equipment in potentially explosive atmospheres.

The IM series uses state-of-the-art circuitry and the latest technology to produce a product that
provides the best explosion protection interfaces on the market.

The IM series of Intrinsically Safe Interface Devices is application specific: Each device is designed to work in a
specific application, be it analog input, analog output, discrete input, discrete output or others.

TURCK designed the IM series to handle most applications where instrumentation and controls are typically installed in potentially explosive
atmospheres, reducing the number of model variations of spares consolidates stocking requirments and making inventory control simpler.

Intrinsic safety has come of age with the introduction of the IM series of Intrinsically Safe Isolating Barriers, making
IS applications in potentially explosive atmospheres safe, simple and economically attractive.

Features
  • Input: 1, 2, or 4 Channel
  • Output: 1, 2 or 5 Non-Hazardous Switching Circuits, 0-20 mA
  • Alarm: Non-Hazardous SPST Switch for open or short circuits
  • Pin Configuration: 18 mm, 12-pin or 27 mm, 20-pin Connectors
  • Housing: Polycarbonate/ABS
  • Temperature Ranges
    • Operating: -25° to +60° C (-13° to +140° F)
    • Storage: -40° to +80° C (-40° to +176° F)
  • Operating Voltage: 20-125 Vdc (20-250 Vac) or 24 Vdc (ranges 10-30 Vdc)
  • Options
    • Relay or Transistor Output Switch
    • Voltage or Current Output
    • HART Compatibility
    • Loop Powered Input
    • Software Configurable with PC for Temperature Relay
    • Configurable Limit Value Relay Output
  • Mounting: DIN Rail or Panel
  • Protection: IP20
  • Intrinsically Safe

TURCK's IM series of Isolating Intrinsically Safe Barriers is designed to be a simple and safe way to solve the
problems associated with the installation of equipment that is used in potentially explosive atmospheres.

TURCK's IM series uses the intrinsically safe concept that is universally accepted, easy to apply and the safest
way to install electronic measuring, monitoring and control equipment in potentially explosive atmospheres.

The IM series uses state-of-the-art circuitry and the latest technology to produce a product that
provides the best explosion protection interfaces on the market.

The IM series of Intrinsically Safe Interface Devices is application specific: Each device is designed to work in a
specific application, be it analog input, analog output, discrete input, discrete output or others.

TURCK designed the IM series to handle most applications where instrumentation and controls are typically installed in potentially explosive
atmospheres, reducing the number of model variations of spares consolidates stocking requirments and making inventory control simpler.

Intrinsic safety has come of age with the introduction of the IM series of Intrinsically Safe Isolating Barriers, making
IS applications in potentially explosive atmospheres safe, simple and economically attractive.

Features
  • Input: 1, 2, or 4 Channel
  • Output: 1, 2 or 5 Non-Hazardous Switching Circuits, 0-20 mA
  • Alarm: Non-Hazardous SPST Switch for open or short circuits
  • Pin Configuration: 18 mm, 12-pin or 27 mm, 20-pin Connectors
  • Housing: Polycarbonate/ABS
  • Temperature Ranges
    • Operating: -25° to +60° C (-13° to +140° F)
    • Storage: -40° to +80° C (-40° to +176° F)
  • Operating Voltage: 20-125 Vdc (20-250 Vac) or 24 Vdc (ranges 10-30 Vdc)
  • Options
    • Relay or Transistor Output Switch
    • Voltage or Current Output
    • HART Compatibility
    • Loop Powered Input
    • Software Configurable with PC for Temperature Relay
    • Configurable Limit Value Relay Output
  • Mounting: DIN Rail or Panel
  • Protection: IP20
  • Intrinsically Safe
Models matching criteria: 7)
TURCK Isolation Switch Relay, 2-Channel, 24 VDC show more
  • IM: Interface Module
  • 1: Isolation Switch Relay
  • 2: Number of Inputs
  • 2: Number of Non-Hazardous Area Outputs, Reflecting Hazardous Area Input Status
  • EX: Intrinsically Safe Associated Apparatus
  • R: Relay Switch
  • 24VDC: Supply Voltage (10-30 VDC)
4 In Stock
$308.35 USD
TURCK Solenoid Driver/Discrete Output Isolator, 2-Channel, Loop Powered show more
  • IM: Interface Module
  • 72: Solenoid Driver/Discrete Output Isolators
  • 2: Number of Hazardous Area Inputs
  • 2: Number of Non-Hazardous Area Current Output Channels
  • EX: Intrinsically Safe Associated Apparatus
  • L: Loop Power
3 In Stock
Non-Cancellable / Non-Refundable
$464.01 USD
TURCK Temperature Converter, 1-Channel, 20-250 VAC / 20-125 VDC show more
  • IM: Interface Module
  • 34: Temperature Measuring Amplifier
  • 1: Number of Hazardous Area Inputs
  • 1: Number of Non-Hazardous Area Outputs
  • EX: Intrinsically Safe Associated Apparatus
  • I:
  • Supply Voltage:  20-250 VAC, 20-125 VDC
  • Approvals: ATEX, IECEx, CFMUS, UL, TR CU, INMETRO, CCOE, NEPSI, KOSHA
2 In Stock
Non-Cancellable / Non-Refundable
$730.11 USD
TURCK Isolator, 2-Channel HARTor Conventional Compatable Analog Input (UL Listed, CFMUS Approved) show more
  • IM: Interface Module
  • 33: Analog Input Repeaters/Supplies
  • 2: Number of Hazardous Area Inputs
  • 2: Number of Non-Hazardous Area Outputs
  • EX: Intrinsically Safe Associated Apparatus
  • HI: HART Compatible
  • 24VDC: Supply Voltage (19-29 VDC)
  • Approvals: ATEX, IECEx, UL, cFMus, TR CU, TIIS, CCOE, Kosha
  • Input Circuits: 0/4...20mA
  • Output Circuits: 0/4...20mA
  • SIL2
  • Removable terminal blocks, screwable with 2mm test socket
  • Complete galvanic isolation
  • Installation in Zone 2
  • Supply of 2-wire measuring transducers with HART communication as well as connection to active 2-wire and passive 3-wire transmitters
  • [/li]
1 In Stock
Non-Cancellable / Non-Refundable
$761.25 USD
TURCK Isolation Switch Relay, 2-Channel, 20-250 VAC / 20-125 VDC show more
  • IM: Interface Module
  • 1: Isolation Switch Relay
  • 2: Number of Inputs
  • 2: Number of Non-Hazardous Area Outputs, Reflecting Hazardous Area Input Status
  • EX: Intrinsically Safe Associated Apparatus
  • R: Relay Switch
  • Universal Supply Voltage: 20-250 VAC / 20-125 VDC
2 - 8 weeks
$338.00 USD
TURCK Isolation Switch Relay, 2-Channel, 20-250 VAC / 20-125 VDC, NPN Outputs show more
  • IM: Interface Module
  • 1: Isolation Switch Relay
  • 2: Number of Inputs
  • 2: Number of Non-Hazardous Area Outputs, Reflecting Hazardous Area Input Status
  • EX: Intrinsically Safe Associated Apparatus
  • T: Transistor Switch
2 - 8 weeks
Non-Cancellable / Non-Refundable
$389.89 USD
TURCK Isolation Switch Relay, 4-Channel, 20-250 VAC / 20-125 VDC, Alarm, Selectable NO/NC Outputs show more
  • IM: Interface Module
  • 1: Isolation Switch Relay
  • 4: Number of Inputs
  • 5: Number of Non-Hazardous Area Outputs, Reflecting Hazardous Area Input Status
  • 1: Number of Additional Non-Hazardous Area Alarm Outputs
  • EX: Intrinsically Safe Associated Apparatus
  • T: Transistor Switch
2 - 8 weeks
Non-Cancellable / Non-Refundable
$768.66 USD

Specifications

Accuracy

  • ≤ 0.1 % of Full Scale Output
  • ≤ 0.2 % of Full Scale Output

Alarm

  • None
  • Non-Hazardous Area Alarm Switch

Ambient Temperature Range

  • -25° to 70° C (-13° to 158° F)

Approvals & Certifications

  • CSA
  • FM

Circuit Protection

  • Short Circuit Current 8.2 mA

Electrical Connectors

  • 4 times 3-Pole Removable Terminal Blocks, Reverse Polarity Protected, Screw Connection

Enclosure, Body Material

  • Polycarbonate/ABS

Environmental Protection

  • IP20

Frequency

  • 40 to 70 Hz

Indication

  • LED Indicators for Readiness, Switching, & Error

Input

  • One Channel
  • Two Channel
  • Four Channel

Mounting

  • DIN Rail Mounting
  • Panel Mount

Output

  • 20-125 Vdc
  • 20-250 Vac
  • 4-20 mA

Output Format

  • Configurable Limit Value Relay Output
  • Current Output
  • Relay Output
  • Software Configurable
  • Transistor Output
  • Voltage Output

Storage Temperature

  • -40° to 80° C (-40° to 176° F)

Supply Voltage

  • 19-29 Vdc
  • 24 Vdc

Switch Type

  • SPST