Images are representations only.

CCS DUAL-SNAP Diff. Pressure Switch, Pre-Set, Haz. Area, 1/8" NPT 300 SST Port, Polyimide, Buna-N

Price
Request a Quote
Stock
Contact For Inventory
Does not ship to OH, United States
Description
SWITCH,PRES,1P2T,(2)1/8 IN FPT,#226A2481 SWITCH,PRESSURE: ELECTRICAL RATING: 120/250/480 VAC 15 A, 125 VDC 0.4 A; SIZE/CONNECTION: (2)1/8 IN FPT; CONNECTION LOCATION: BOTTOM; RANGE: 17+/- 2 PSID INCR, 12 +/- 2 PSID DECR, 4500 PSIG PROOF; ACTION: 1P2T; ENCLOSURE: NEMA 4, 7, 9, 13; STANDARD/SPECIFICATION: GOST 26005, CSA; ADDITIONAL DATA: TYPE: DIFFERENTIAL DIFFERENTIAL, FOR FUEL FILTERING MODULE.
SWITCH,PRES,1P2T,(2)1/8 IN FPT,#226A2481 SWITCH,PRESSURE: ELECTRICAL RATING: 120/250/480 VAC 15 A, 125 VDC 0.4 A; SIZE/CONNECTION: (2)1/8 IN FPT; CONNECTION LOCATION: BOTTOM; RANGE: 17+/- 2 PSID INCR, 12 +/- 2 PSID DECR, 4500 PSIG PROOF; ACTION: 1P2T; ENCLOSURE: NEMA 4, 7, 9, 13; STANDARD/SPECIFICATION: GOST 26005, CSA; ADDITIONAL DATA: TYPE: DIFFERENTIAL DIFFERENTIAL, FOR FUEL FILTERING MODULE.

Specifications

Adjustment Type

  • Factory Set (Pre-Set)

Approvals & Certifications

  • ATEX
  • CE
  • CRN
  • CRN - Alberta
  • CRN - British Columbia
  • CRN - Manitoba
  • CRN - N.W. Territories
  • CRN - Saskatchewan
  • CSA
  • cUL
  • EMC
  • LVD
  • PED
  • RoHS
  • RTN
  • UL

Deadband, Approximate - Bottom of Range

  • bar: 0.345 to 4.13
  • kPa: 34.5 to 413.6
  • psi: 5 to 60

Deadband, Approximate - Top of Range

  • bar: 0.83 to 8.23
  • kPa: 82.8 to 827.3
  • psi: 12 to 120

Diaphragm Material

  • Polyimide

Electrical - Free Leads

  • 18” (45 cm) Free Leads
  • 18” (45 cm) Teflon Leadwire

Electrical Assembly

  • Hermetic Seal

Electrical Certification

  • ATEX - Certified for Potentially Explosive Atmospheres Electrical Assembly Series 46-XXXXXXX, Models
  • c-UL, UL/CSA Explosion-proof: Div. 1, 2 Hermetically Sealed Electrical Assembly P/N 46-1058 (46-1061 for M (DPDT) Model Option), Listed by Both Underwriter's Laboratories, Inc. (File No. E32961) & Canadian Standard Association (CSA) Testing Laboratories
  • IECEx - SIRA Certified, SIR 10,0193X (Option Y)

Electrical Contacts

  • Gold
  • Silver

Electrical Rating

  • 1 A at 125 Vac, 50/60 Hz
  • 11 A at 125/250 Vac

Enclosure, Body Material

  • Aluminum

Environmental Protection

  • Hazardous Area
  • IP54
  • IP66
  • NEMA 13
  • NEMA 4, 7, 9, 13 / IP54, 66
  • NEMA 7
  • NEMA 9

NPT Connection

  • 1/8” NPT Female

O-Ring Material

  • Ethylene Propylene (EPR)
  • Viton

Operating Temperature

  • -40° to 86° C (-40° to 187° F)

Process Connection Material

  • 316 Stainless Steel

Proof Pressure - Both Ports

  • bar: 310
  • kPa: 31,026
  • psig: 4,500

Proof Pressure - High Over Low

  • kPa: 17,237
  • psig: 2,500

Proof Pressure - Low Over High

  • bar: 172
  • psig: 2,500

Service

  • Sweet (Oil & Gas)

Set Point - Decreasing

  • bar: 0.14 to 46.88
  • kPa: 13.8 to 468.8
  • psid: 2 to 680

Set Point - Increasing

  • bar: 0.48 to 55.15
  • kPa: 48.3 to 5,516
  • psid: 7 to 800

Switch Type

  • DPDT
  • SPDT

System Pressure

  • bar: 207
  • kPa: 20,684
  • psig: 3,000

Similar SKUs

674DE1 @ 60 KPA INCR
674DE1 @ 60 KPA INCR
674DE Series Pressure Switch
Custom Control Sensors
Request a Quote
10 - 12 weeks
CCS DUAL-SNAP Diff. Pressure Switch, Pre-Set, Haz. Area, 1/8" NPT 300 SST Port, Polyimide, Buna-N
674DE2 @ 95 PSI INCR
674DE2 @ 95 PSI INCR
674DE Series Pressure Switch
Custom Control Sensors
Request a Quote
10 - 12 weeks
CCS DUAL-SNAP Diff. Pressure Switch, Pre-Set, Haz. Area, 1/8" NPT 300 SST Port, Polyimide, Buna-N
674DE3 @ 450 PSI INCR
674DE3 @ 450 PSI INCR
674DE Series Pressure Switch
Custom Control Sensors
Request a Quote
10 - 12 weeks
CCS DUAL-SNAP Diff. Pressure Switch, Pre-Set, Haz. Area, 1/8" NPT 300 SST Port, Polyimide, Buna-N
674DE3 @ 605 PSI INCR
674DE3 @ 605 PSI INCR
674DE Series Pressure Switch
Custom Control Sensors
Request a Quote
10 - 12 weeks
CCS DUAL-SNAP Diff. Pressure Switch, Pre-Set, Haz. Area, 1/8" NPT 300 SST Port, Polyimide, Buna-N
674DEM1
674DEM1
674DE Series Pressure Switch
Custom Control Sensors
Request a Quote
10 - 12 weeks
CCS DUAL-SNAP Diff. Pressure Switch, Pre-Set, Haz. Area, 1/8"NPT 300 SST Port,Polyimide,Buna-N,DPDT
674DEM2
674DEM2
674DE Series Pressure Switch
Custom Control Sensors
Request a Quote
10 - 12 weeks
CCS DUAL-SNAP Diff. Pressure Switch, Pre-Set, Haz. Area, 1/8"NPT 300 SST Port,Polyimide,Buna-N,DPDT
DO NOT USE
DO NOT USE
674DE Series Pressure Switch
Custom Control Sensors
Request a Quote
Out of Stock
CCS DUAL-SNAP Diff. Pressure Switch, Pre-Set, Haz. Area, 1/8"NPT 300 SST Port,Polyimide,Buna-N,DPDT
674D1 @ 60 KPA INCR
674D1 @ 60 KPA INCR
674D Series Pressure Switch
Custom Control Sensors
Request a Quote
Out of Stock
CCS DUAL-SNAP Diff. Pressure Switch, Pre-Set, Non-Haz. Area, 1/8" NPT 300 SST Port, Polyimide,Buna-N