Thermal Flow Switches

Thermal flow switches detect and monitor the flow of a fluid (liquid or gas) in a pipeline or system by measuring changes in temperature. It operates based on the principle of heat transfer, when a fluid flows over a heated sensor, it cools the sensor due to the thermal conductivity of the fluid. The rate of cooling provides an indication of the fluid's flow rate. When the flow falls below or exceeds a predefined setpoint, the thermal flow switch triggers an electrical circuit to take specific actions, such as activating an alarm, shutting down equipment, or controlling pumps and valves.

1 - 29 of 29 Products
USB Adaptor for use with Kayden® SCA Adapter, A15-323
Kayden Instruments
Kayden RS485/USB Adapter
Request Information
USB Adaptor for use with Kayden® SCA Adapter, A15-322
Kayden Instruments
Kayden RS232/USB Adapter
Request Information
Serial Communication Adaptor RS-232 to RS-485, A15-321
Kayden Instruments
Kayden RS232/RS485 Serial Communication Adapter
Request Information
PDA8008 ProVu USB Serial Adapter
Precision Digital
PDA8008.png
Request Information
Kayden® CLASSIC® 832 Thermal Flow Switch & Transmitter
Kayden Instruments
Kayden InLine Flanged Flow Switch
Configure for Pricing
Kayden USB to RS-485 Convertor Cable
Kayden Instruments
Picture1.jpg
Request Information
Kayden Rolled Duct Flange
Kayden Instruments
duct flange - rolled (003).png
Configure for Pricing
Kayden RCM Software Rev 7.2.0
Kayden Instruments
RCMHomepage_tiny.png
Request Information
Kayden Instrumentation Cable, General-Purpose, for Remote Electronics, A05-GP
Kayden Instruments
Kayden General Purpose Remote Cable
Request a Quote
Kayden Instrumentation Cable, General-Purpose, 2 x T&B Star Teck Extreme Cable Fittings, A06-GP
Kayden Instruments
Kayden General Purpose Cable & Connector Assembly
Request a Quote
Kayden Instrumentation Cable, Flameproof, 2 x T&B Star Teck Cable Fittings, A06-XP
Kayden Instruments
Kayden Flameproof Cable & Connector Assembly
Request a Quote
Kayden High Temp A05-TFE Instrumentation Cable Assembly to Connect Kayden Sensor Probe to Remote Electronics Plug-in Base
Kayden Instruments
A05-TFE.png
Request a Quote
Kayden Flat Duct Flange
Kayden Instruments
duct flange - flat.png
Request a Quote
Kayden CLASSIC® Spare Glass Lens Cover, for CLASSIC® 800 Series Local Electronics Enclosure, M10-1G00
Kayden Instruments
Kayden Glass Lens Cover, CLASSIC Series
$246.24 USD
Kayden CLASSIC® Spare Blind Cover, for CLASSIC® 800 Series Local Electronics Enclosure, M10-1B00
Kayden Instruments
Kayden Blind Cover, CLASSIC Series
Request Information
Kayden CLASSIC® 800 Series Spare Electronics Module, L10-800-C-E
Kayden Instruments
KAYDEN CLASSIC 800 Series Thermal Switch/Transmitter Electronics Module
$902.13 USD
Kayden CLASSIC Spare Glass Lens Cover, for CLASSIC 800 Series Remote Electronics Enclosure, M50-001G
Kayden Instruments
CLASSIC® Spare Glass Lens Cover, for CLASSIC® 800 Series Remote Electronics Enclosure, M50-001G
$246.24 USD
Kayden CLASSIC 832 Spare Sensor, In-Line Flanged, P52 Series
Kayden Instruments
Kayden Thermal Flow Sensor, CLASSIC Series
Request a Quote
Kayden CLASSIC 830 Thermal Flow Switch & Transmitter
Kayden Instruments
Kayden InLine Threaded Flow Switch
Configure for Pricing
Kayden CLASSIC 830 Spare Sensor, In-Line Threaded, 3/4" FNPT, P42 Series
Kayden Instruments
Kayden Thermal Flow Sensor, CLASSIC Series
Request a Quote
Kayden CLASSIC 816 Thermal Flow, Level, Interface Switch & Transmitter
Kayden Instruments
Kayden Retractable Flow, Level & Interface Switch
Configure for Pricing
Kayden CLASSIC 816 Spare Sensor, Retractable Threaded Packing Gland, P32 Series
Kayden Instruments
Kayden Thermal Flow, Level, Interface Sensor, CLASSIC Series
Request a Quote
Kayden CLASSIC 814 Thermal Flow, Level, Interface Switch & Transmitter
Kayden Instruments
Kayden Retractable Flow, Level & Interface Switch
Configure for Pricing
Kayden CLASSIC 814 Spare Sensor, Retractable Flanged Packing Gland, P22 Series
Kayden Instruments
Kayden Flow, Level & Interface Sensor, CLASSIC Series
Request a Quote
Kayden CLASSIC 812 Thermal Flow, Level, Interface Switch & Transmitter
Kayden Instruments
Kayden CLASSIC 812 Thermal Flow, Level, Interface Switch & Transmitter
Configure for Pricing
Kayden CLASSIC 812 Spare Sensor, Flanged, P12 Series
Kayden Instruments
Kayden Flow, Level & Interface Sensor, CLASSIC Series
Request a Quote
Kayden CLASSIC 810 Thermal Flow, Level, Interface Switch & Transmitter
Kayden Instruments
Side View of the Kayden CLASSIC 810 Series Threaded Flow and Level Switch
Configure for Pricing
Kayden CLASSIC 810 Spare Sensor, 1/2" thru 2" MNPT, P02 Series
Kayden Instruments
Kayden Flow, Level & Interface Sensor, CLASSIC Series
Request a Quote
Kayden CLASSIC 800 Series, Remote Mounting Base Plate
Kayden Instruments
Front View.png
Request a Quote

Thermal flow switches contain a platinum RTD (Resistance Temperature Detector). This sensor is heated either by an external electrical supply. A second temperature sensor is used as a reference to measure the ambient or baseline temperature of the fluid, this reference sensor helps in determining the rate of cooling of the heated sensor. An electronic controller processes the signals from the sensors, comparing the heated sensor’s temperature to the reference temperature. The controller determines whether the flow is above or below the setpoint and activates an electrical circuit accordingly. The switch includes output relays or contacts that open or close when the flow rate reaches a specific threshold. These relays can be connected to alarms, pumps, valves, or other control systems.

A thermal flow switch works based on the principle of convective heat transfer, the heated sensor is placed in the flow path of the fluid. An electrical current heats the sensor, raising its temperature above the ambient temperature of the fluid. When the fluid is flowing, it cools the heated sensor by carrying away the heat. The amount of cooling depends on the fluid’s flow rate: higher flow rates cause more rapid cooling, while lower flow rates result in less cooling. The controller continuously monitors the temperature of the heated sensor and compares it to the reference sensor or baseline. If the flow rate drops below or rises above a preset level, the thermal flow switch detects this change in temperature difference. When the flow rate reaches the set threshold, the switch triggers its output relay or contacts to take action—such as turning off a pump, closing a valve, sounding an alarm, or sending a signal to a control system.

Thermal flow switches are used to protect pumps from running dry or operating under low flow conditions. If the flow rate drops below the setpoint, the switch can shut down the pump to prevent damage. In chemical, petrochemical, and pharmaceutical industries, thermal flow switches are used to monitor and control the flow of various process fluids, providing safety interlocks and ensuring consistent production quality. In cooling and heating applications, such as HVAC systems or industrial process cooling, thermal flow switches monitor the flow of coolant or heating fluids to ensure adequate circulation and prevent overheating or freezing. In water treatment, filtration, or chemical dosing systems, ther help ensure that the required flow rate is maintained for optimal treatment or mixing. In air and gas flow monitoring systems, and pneumatic systems, compressed air lines, and gas delivery systems, thermal flow switches detect low or no-flow conditions to prevent issues such as air supply loss or gas leakage.

Thermal flow switches are suitable for both liquids, gases, and slurries. Thermal flow switches have no moving parts, making them less prone to mechanical failure, reducing maintenance requirements, and enhancing durability in harsh environments. Available in insertion or inline configurations, thermal flow switches can be installed in various setups and orientations, providing flexibility for different applications. Thermal switches are capable of providing accurate flow detection even under varying temperature and pressure conditions, ensuring reliable performance.